• 제목/요약/키워드: oscillatory

Search Result 714, Processing Time 0.021 seconds

Dynamic Characteristics of Moving Coil Linear Oscillatory Actuator Considering the Variable Inductance and Push/pull Effects (가동차 위치에 따른 인덕턴스 변화와 Push/Pull 효과를 고려한 가동코일형 LOA의 동특성)

  • Jeong, Sang-Sub;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.307-314
    • /
    • 2001
  • A moving coil linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The variation of mover position and the consequent changes of coil flux path affect the coil inductance, because coil flux leaks at the open region of LOA stator. The interaction between permanent magnet and armature field is to shift the airgap flux density variation due to the magnet alone by a certain amount. The unbalanced reciprocation force due to armature reaction field decreases the advantage of moving coil LOA, such as a high degree of linearity and controllability in the force ad motion control. This paper firstly describes the coil inductance, the deviation of flux density, and the unbalanced reciprocation force, which are derived form the permeance model of LOA. Secondly, the analytical method are verified using the 2D finite element method and tests. Finally, the dynamic simulation algorithm taking the armature reaction effect and variable inductance into account, is proposed and confirmed through the experiment.

  • PDF

Improvement of Rheological Properties of Silica Composites Employing Response Surface Methodology (반응표면분석법을 이용한 실리카복합재료의 레올로지 속성 개선)

  • Yim, Gie-Hong;Yang, Seung-Nam;Kim, Nam-Ki
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2008
  • The purpose of this study was improving the rheology properties of dentifrice by finding optimum binders polymer system which consists of carboxymethylcellulose (CMC), carbomer, and Mg/Al silicate. Response surface methodology (RSM) was employed to investigate the correlation between polymers and rheological properties of dentifrice and to optimize responses. Rheological properties were measured with oscillatory rheometer. As a result, it was identified that gel strength and yield stress were dependent on contents of CMC and carbomer and CMC caused long stringiness of dentifrice. And springness of dentifrice was dependent on contents of CMC and Mg/Al silicate. Optimum components proportion of polymers and silicate were obtained by responses optimization process. According to determined optimum components proportion, it was possible to observe a dentifrice with improved rheological properties.

Flow Characteristics of a Turbulent Pulsating Flow in a Straight Duct Connected to a Curved Duct by using an LDV (LDV에 의한 곡관 후류에 연결된 직관에서 난류맥동유동의 유동특성)

  • 손현철;이행남;박길문
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.177-186
    • /
    • 2003
  • In the present study, the flow characteristics of developing turbulent flows are investigated at the exit region of a square cross-sectional 180" curved duct with dimensions of 40mm$\times$40mm$\times$4000mm (height $\times$ width $\times$length). Smoke particles produced from mosquito coils were used as seed particles for the LDV measurement. Experiments were carried out to measure axial velocity profiles, shear stress distributions and entrance lengths by using an LDV system and Rotating Machinery Resolver RMR with PHASE software. Experimental results clearly show that the time-averaged Reynolds number does not affect oscillatory flow characteristics because the turbulent components tend to balance the oscillatory components in the fully developed flow region. Also, the velocity profiles are in good agreement with 1/7power law such as the results of steady turbulent flows. The turbulent intensity linearly increases along the walls and is slightly higher, especially in the period of deceleration. On the other hand, the LDV measurements show that shear stress values in slightly higher in the period of deceleration due to the flow characteristics in the exit region. The entrance length where flows become stable appears at the point that is 40 times the length of hydraulic diameter.eter.

Air Compressibility Effect in CFD-based Water Impact Analysis (CFD 기반 유체충격 해석에서 공기 압축성 효과)

  • Tran, Huu Phi;Ahn, Hyung-Taek
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.6
    • /
    • pp.581-591
    • /
    • 2011
  • This paper describes the air compressibility effect in the CFD simulation of water impact load prediction. In order to consider the air compressibility effect, two sets of governing equations are employed, namely the incompressible Navier-stokes equations and compressible Navier-Stokes equations that describe general compressible gas flow. In order to describe violent motion of free surface, volume-of-fluid method is utilized. The role of air compressibility is presented by the comparative study of water impact load obtained from two different air models, i.e. the compressible and incompressible air. For both cases, water is considered as incompressible media. Compressible air model shows oscillatory behavior of pressure on the solid surface that may attribute to the air-cushion effect. Incompressible air model showed no such oscillatory behavior in the pressure history. This study also showed that the CFD simulation can capture the formation of air pockets enclosed by water and solid surface, which may be the location where the air compressibility effect is dominant.

Dynamic Characteristics of Moving Coil Type Linear Oscillatory Actuator (가동코일형 리니어 왕복 액추에이터의 동특성)

  • Jang, S.M.;Jeong, S.S.;Kweon, C.;Park, H.C.;Moon, S.J.;Park, C.I.;Chung, T.Y.
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.180-187
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. This set of equations was manipulated in state-space form. The EMF constant kE of equation parameters in state-space form can be obtained by using the induced voltage in armature coils at open circuit test. kE and other parameters provide the system matrices and transfer function for frequency response and dynamic simulation. Voltage source inverter-fed LOA is examined aiming to compare with results of simulation.

  • PDF

Performance Improvement of Moving Coil Type Linear Oscillatory Actuator Considering Asymmetric Magnetic Circuit (자기회로 불평형을 고려한 가동 코일형 리니어 진동 엑츄에이터의 운전특성 개선)

  • Kim, Duk-Hyun;Eum, Sang-Joon;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.713-719
    • /
    • 2000
  • This paper presents an approach toward improving the performance of Moving Coil Type Linear Oscillatory Actuator (MC-LOA) with the application of Finite Element Method (FEM) to a simple control system. MC-LOA has an unbalanced magnetic circuit due to its asymmetric structure and there is a different flux distribution on the air-gap along the current direction. The interaction driven by two fluxes between the Permanent Magnet (PM) and the current causes the unbalanced thrust and interferes with the proper oscillation of MC-LOA. In order to solve the above problems and improve the driving performance, it is necessary to analyze the rate of the unbalanced thrust according to the current direction by using FEM. Then, the analysis results are used to determine the input currents for both directions. Controlling the input currents can be easily achieved by a simple control system, such as Pulse Width Modulation (PWM), without complex units. The validity of the approach is verified by the experimental results.

  • PDF

Analysis on Eddy Current Losses for Cylindrical Linear Oscillatory Actuator with Halbach Array according to Drive Voltage Waveform (영구자석 Halbach형 원통형 액추에이터의 구동전압 파형에 따른 와전류 손실)

  • Jang, Seok-Myeong;Kim, Hyun-Kyu;Park, Ji-Hoon;Ko, Kyoung-Jin;Choi, Jang-Young;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.49-51
    • /
    • 2009
  • This paper deals with the analysis on eddy current losses for cylindrical linear oscillatory actuator (LOA) with Halbach array mover according to voltage waveform. This paper presents analytical procedures for calculation of eddy current losses using Poynting theorem. On the basis of the magnetic vector potential and a two-dimensional (2-d) cylindrical coordinate system, this paper derived analytical solutions of eddy current tosses using phase current analysis. The eddy current losses of each harmonic obtained by fast Fourier transform (FFT) analysis of phase current are compared with results obtained from finite-element method (FEM). Particularly, this paper shows that the eddy current losses of cylindrical LOA according to square voltage waveform are more significant than those according to sinusoidal voltage waveform.

  • PDF

Electromagnetic Susceptiblity Experiments for Battery Protection Circuit Module (배터리 보호회로 모듈에 대한 전자파 내성 실험)

  • Park, Kyung-Je;Yoo, Jong-Gyeong;Lee, Dae-Heon;Yeo, Junho;Cho, Young-Ki;Kim, Jong-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.57-58
    • /
    • 2017
  • In this paper, we have studied electromagnetic susceptibility tests of the battery protection circuit module of a lithium ion battery. Electromagnetic susceptibility tests can be divided into conducted susceptibility for electromagnetic waves flowing through power lines, input / output lines, antenna ports, and radiated susceptibility for spatially radiated electromagnetic waves. A lithium ion battery of S company was used as an experimental sample, and conducted susceptibility tests were conducted on Surge (IEC 61000-4-5), Ring wave (IEC 61000-4-12), and Damped oscillatory wave(IEC 61000-4-18). Radiated susceptibility tests were performed according to IEC 61000-4-3.

  • PDF

Nonlinear response of complex fluids under LAOS(large amplitude oscillatory shear) flow

  • Ahn, Kyung-Hyun;Kyu Hyun;Nam, Jung-Gun;Manfred Wilhelm;Lee, Seung-Jong
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • In the previous paper (Hyun et al.,2002), we have investigated the shape of storage modulus (G') and loss modulus (G") of complex fluids under large amplitude oscillatory shear (LAOS) flow. As the strain amplitude increases, owever, the stress curve becomes distorted and some important information may be smothered during data processing. Thus we need to investigate the stress data more precisely and systematically. In this work, we have obtained the stress data using high performance ADC (analog digital converting) card, and investigated the nonlinear response of complex fluids, 4wt% xanthan gum (XG), 2 wt% PVA/ 1 wt% Borax, and 1 wt% hyaluronic acid (HA) solutions, using Fourier transformation (FT) rheology. Comparing the strain signals in time domain with FT parameters in frequency domain, we could illustrate the sensitivity and importance of FT rheology. Diverse and unique stress patterns were observed depending on the material system as well as flow environment. It was found that they are not the outcome of experimental deficiency like wall slip but characteristics of the material system. When nonlinear response of complex fluids is analyzed, the intensity and phase angle of higher harmonic contributions should be considered together, and the shape of the stress signal was found to be strongly dependent upon phase angle.ngle.

Numerical study on flux of cohesive sediment by asymmetric oscillatory flow (비대칭 진동흐름에 의한 점착성 유사의 이동량 수치연구)

  • Son, Min-Woo;Jung, Tae-Hwa;Baek, Kyong-Oh;Cho, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.505-509
    • /
    • 2012
  • 본 연구의 목적은 천해 환경에서의 파형이 점착성 유사의 이동량에 미치는 영향을 살펴보는 것이다. 이를 위하여 이상적인 진동흐름(Oscillatory Flow)을 가정하고 점착성 유사의 이동에 적합한 1DV 모형을 적용하였다. 이상적인 진동흐름을 가정할 때는 다양한 파형을 고려하기 위해 왜곡되거나 비대칭적인 조건을 적용하였다. 크기와 밀도가 변화하는 점착성 유사의 응집현상을 고려하기 위해 기존에 개발된 응집현상 모형을 1DV 모형에 결합하였다. 2차 스토크스파 조건을 모사하기 위해 왜곡된 진동흐름, 톱니파를 모사하기 위해 비대칭 진동흐름 조건을 선택하였다. 수치모의 결과, 왜곡된 진동흐름 조건에서의 점착성 유사 이동량은 흐름의 왜곡도에 큰 영향을 받는 것으로 나타났다. 반면 가는 비점착성 유상의 경우는 왜곡도와 주목할 만한 관계를 보이지 않았다. 비대칭 진동흐름의 경우는 점착성 유사와 비점착성 유사가 서로 다른 방향을 나타내었다. 앞쪽으로 기운 비대칭 진동흐름 조건에서 점착성 유사의 이동량이 뒤쪽 방향으로 발생하는 반면 비점착성 유사는 흐름이 기운 방향과 동일한 방향으로 유사량을 나타내었다. 이러한 현상의 원인으로는 Phase-lag 효과가 고려되었다. 유사의 침강속도와 농도 프로파일의 변화, 물의 유동 조건 등은 복합적인 상호작용을 통해 Phase-lag 효과를 강화시키고 점착성 유사와 비점착성 유사의 이동량이 서로 다른 특성을 나타내게 하는 것으로 고려된다.

  • PDF