• Title/Summary/Keyword: order contrast

Search Result 1,651, Processing Time 0.03 seconds

A DENSITOMETRIC STUDY OF THE DENTAL FILMS IN COMBINATION WITH VARIABLE PROCESSING SOLUTIONS (현상법 현상액에 따른 필름특성에 관한 연구)

  • Kim Ho Cheol;Park Jae Kwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.197-207
    • /
    • 1987
  • This study was undertaken to investigate the relationships between film and processing solution at different processing temperatures. Three kinds of periapical film were used for this study. They included EP-2l film, DF-58, and A film Each film was processed by automatic film processor with RD-Ⅲ X-dol 90, and A processing solutions at 68° 74° 80° 86° and 92°F. Film density was measured with the densitometer, and base plus fog density, film relative speed, film contrast, and subject contrast were evaluated. The following results were obtained; 1. As the processing temperature was increased, base plus density was increased. Inadequate base plus fog densities were obtained with three films in combination with three processing solutions at 92°F. 2. Lowest base plus fog densities were obtained with A film, followed in ascending order by EP-21, and DF-58 film in combination with A or RD-Ⅲ processing solutions. The sequence of base plus fog densities was in ascending order by EP-21, A, and DF-58 film in combination with X-dol 90 processing solution. 3. The sequence of film relative speed values was in ascending order of EP-21, A, and DF-58 film in combination with A and RD-Ⅲ processing solutions, respectively. 4. As the processing temperature was increased, film contrast values was increased. The sequence of film contrast values was in descending order solution. The sequence of film contrast values was in descending order of EP-2l, DF-58, and A film in combination with RD-Ⅲ, X-dol 90 processing solution at 80°F. 5. As the processing temperature was increased, subject contrast was increased. The sequence of subject contrast was in descending order of A, X-dol 90, and RD-Ⅲ processing solution in combination with three films at 80°F. The sequence of subject contrast was in descending order of EP-21, A, and DF-58 film in combination with A processing solution at different processing temperatures.

  • PDF

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter (X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구)

  • Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

Understanding of Perfusion MR Imaging (관류자기공명영상의 이해)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium (CT 조영제가 MR 조영제의 이완율에 미치는 영향)

  • Kwon, Soon-Yong;Kang, Chung-Hwan;Jeong, Hyeon Keum;Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

A decision support system the interface between PACS and Laboratory Information (PACS 와 임상검사정보의 연동으로 인한 의사결정시스템; 크레아틴 수치정보전송으로 인한 조영제 부작용 예방)

  • Kim, Sean-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.17-19
    • /
    • 2007
  • This study applies in case of operating an exam using by the contrast order or inputting an order of a contrast media the exam of Radiology Department. It is developed for helping decision making as regards a process of an exam from reading the creatinine value automatically linked with Laboratory Information System. It can be confirmed by real-time information; therefore, the creditability of the information is able to be improved. We will create the base for Patient Monitoring System with the data from the side effect of the creatinine value and allergies. Decision Support System minimize the inconvenience and the riskiness of the given contrast medium for CT tests. We would like to improve medical services by providing a standard circumstance where patients are able to run tests safely and comfortably.

  • PDF

Ultrasound Contrast Agent (초음파 조영제)

  • Kim, Gi-Wook
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.86-92
    • /
    • 2021
  • Ultrasound imaging in clinical practice is one of the widely used diagnostic methods because there is no radiation risk, more cost- effective compared to MRI or CT, and possible to perform an intervention through fast real-time imaging. In order to increase the diagnostic value, the studies of contrast-enhanced ultrasound (CEUS) using an ultrasound contrast agent have been actively conducted since about 50 years ago and are being used clinically in vascularity and microcirculation of internal organs. Although ultrasound is actively used for the diagnosis and treatment of various diseases in musculoskeletal disorders, there are some limitations in diagnosing mild or small lesions, inflammatory reactions, or abnormalities at the molecular level. In this review, the principles, types, and research, and clinical applications of ultrasound contrast agents have been summarized and introduced. If we understand the characteristics of the ultrasound contrast agents and anatomical knowledge, as well as molecular changes, the ultrasound contrast agents are widely applied in musculoskeletal disorders and have tremendous potential for diagnosis and treatment.

A Study on Luminance Contrast Criteria for Tactile Walking Surface Indicators (시각장애인 점자블록의 휘도대비 기준에 대한 연구)

  • Shin, Dong-Hong;Park, Kwang-Jae;Kim, Sang-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are the number of color tactile walking surface indicators installed in Korea, because of indefinite regulation in blind and vision-impaired persons' tactile walking surface indicators. In case of yellow tactile walking surface indicators, it shows a deviation severe color. In this study, the researchers suggested color and brightness reference for helping blind and vision-impaired persons' walking through analyzing the color references of tactile walking surface indicators and the color luminance between tactile walking surface indicators and sidewalk currently used. Method: Reasonable luminance contrast criteria is suggested by examining ways of improving the recognition and recognition of objects according to color contrast visually impaired through literature review and analyzing standards of tactile walking surface indicators and the Europe, Japan and Australia of color and luminance contrast criteria. And by examining the color of the tactile walking surface indicators reported in Korea currently used to derive the problem presented by the luminance contrast in the reference and comparison. Finally, the visually impaired tactile walking surface indicators is set for color selection criteria for the recognition rate improves. Results: In order to improve the recognition rate to be tactile walking surface indicators of the contrast of the visually impaired and the environment than the color of the tactile walking surface indicators itself to secure always a certain level or more of brightness contrast values in the set of the color of the tactile walking surface indicators so important. Implication: In order to set the blind tactile walking surface indicators color recognition based on the verification of the real pedestrian based on the results presented in this paper it is required. It is to be understood as an element of the barrier free configuration for securing the walking pedestrian safety.

High-harmonic Generation from Solid Surface Using an Oscillating Mirror Model and Plasma Mirror System for High Contrast Laser Pulse

  • Kim, I-Jong;Choi, Il-Woo;Janulewicz, Karol Adam;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • High-order harmonic generation from a solid surface affected by the contrast of a laser pulse was studied using an oscillating mirror model. High-order harmonics generated from solid surfaces have unusual properties such as spectral redshift, and an intensity difference between even- and odd-order harmonics which is not reported for high-order harmonics generated by a gas medium. We confirmed that high-order harmonics from solid surfaces have selectivity of polarization as well as cut-off extension and the enhancement of conversion efficiency proportional to laser intensity. And the principle of operation and the characteristics of a plasma mirror system developed for achieving high contrast laser pulses to pursue the experimental realization of high-harmonic generation from solid surfaces are reported. Energy fluence on the plasma mirrors is tunable between $10\;J/cm^2$ and $1000\;J/cm^2$ and around 1000 shots are available before the plasma mirrors require replacement.