• Title/Summary/Keyword: oral temperature

Search Result 307, Processing Time 0.03 seconds

A Study on the Applicability of Acrylic Water Leak Repair Materials used to Repair Cracks in Conduits and Underground Structures (관거 및 지하구조물 균열 보수에 사용되는 아크릴 누수 보수재의 적용성에 대한 연구)

  • Eunmi Lee;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2024
  • Various injection materials, such as asphalt-based injection materials, urethane-based injection materials, cement- based injection materials, and acrylic-based injection materials, are used for the repair of aged conduits and underground structures with cracks. In this study, research was conducted on an environmentally friendly acrylic- based leak repair material that exhibits good curing properties even in humid conditions and stability in temperature fluctuations. To compare the performance of the improved acrylic leak repair material with the existing acrylate injection material, experiments were conducted using KS standard methods, including underwater length change rate tests, underwater leakage resistance tests, and chemical performance tests. The comparative experiments revealed that the improved acrylic leak repair material showed no changes in shrinkage due to humidity, temperature variations, or chemical reactions compared to the existing acrylate injection material. In the underwater resistance test, the improved acrylic leak repair material did not show any leakage. Additionally, to assess the environmental impact of the improved acrylic leak repair material, acute fish toxicity tests and acute oral toxicity tests were conducted, and the results showed no mortality and no specific concerns with the test specimens. The experimental results led to the conclusion that the improved acrylic leak repair material is considered to be superior in performance, environmentally safe, and harmless to the human body. Based on various experimental results, it is inferred that the improved acrylic leak repair material is suitable for use as a repair material for cracks in manholes and underground structures compared to the existing acrylate repair material. This study aims to propose valuable data for future technological development by evaluating the applicability of acrylic leak repair materials.

Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm (임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향)

  • 황애란;정현숙;임영신;이혜원;김조자
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.2
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF

Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin (치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도)

  • Moon, Yun-Hee;Lee, Jonghyuk;Lee, Myung-Gu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.193-202
    • /
    • 2016
  • Purpose: This study was performed in order to assess the effect of the surface treatment methods and the use of bonding agent on the shear bond strength (SBS) between the aged CAD-CAM (computer aided design-computer aided manufacturing) hybrid materials and added composite resin. Materials and methods: LAVA Ultimate (LU) and VITA ENAMIC (VE) specimens were age treated by submerging in a $37^{\circ}C$ water bath filled with artificial saliva (Xerova solution) for 30 days. The surface was ground with #220 SiC paper then the specimens were divided into 9 groups according to the combination of the surface treatment (no treatment, grinding, air abrasion with aluminum oxide, HF acid) and bonding agents (no bonding, Adper Single Bond 2, Single Bond Universal). Each group had 10 specimens. Specimens were repaired (added) using composite resin (Filtek Z250), then all the specimens were stored for 7 days in room temperature distilled water. SBS was measured and the fractured surfaces were observed with a scanning electron microscope (SEM). One-way ANOVA and Scheffe test were used for statistical analysis (${\alpha}=.05$). Results: Mostly groups with bonding agent treatment showed higher SBS than groups without bonding agent. Among the groups without bonding agent the groups with aluminum oxide treatment showed higher SBS. However there was no significant difference between groups except two subgroups within LU group, which revealed a significant increase of SBS when Single Bond Universal was used on the ground LU specimen. Conclusion: The use of bonding agent when repairing an aged LAVA Ultimate restoration is recommended.

A comparative study on the user satisfaction between two different piezoelectric engines (두가지 피에조 엔진의 사용자 만족도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Choi, So-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.269-277
    • /
    • 2017
  • Purpose: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. Materials and Methods: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. Results: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below $41^{\circ}C$ after having been operated for 3 minutes. Conclusion: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.

Risk of Treatment Related Death and Febrile Neutropaenia with First Line Palliative Chemotherapy for De Novo Metastatic Breast Cancer in Clinical Practice in a Middle Resource Country

  • Phua, Chee Ee;Tang, Weng Heng;Yusof, Mastura Md.;Saad, Marniza;Alip, Adlinda;See, Mee Hoong;Taib, Nur Aishah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10263-10266
    • /
    • 2015
  • Background: The risk of febrile neutropaenia (FN) and treatment related death (TRD) with first line palliative chemotherapy for de novo metastatic breast cancer (MBC) remains unknown outside of a clinical trial setting despite its widespread usage. This study aimed to determine rates in a large cohort of patients treated in the University of Malaya Medical Centre (UMMC). Materials and Methods: Patients who were treated with first line palliative chemotherapy for de novo MBC from 2002-2011 in UMMC were identified from the UMMC Breast Cancer Registry. Information collected included patient demographics, histopathological features, treatment received, including the different chemotherapy regimens, and presence of FN and TRD. FN was defined as an oral temperature > $38.5^{\circ}C$ or two consecutive readings of > $38.0^{\circ}C$ for 2 hours and an absolute neutrophil count < $0.5{\times}10^9/L$, or expected to fall below $0.5{\times}10^9/L$ (de Naurois et al, 2010). TRD was defined as death occurring during or within 30 days of the last chemotherapy treatment, as a consequence of the chemotherapy treatment. Statistical analysis was performed using the SPSS version 18.0 software. Survival probabilities were estimated using the Kaplan-Meier method and differences in survival compared using log-rank test. Results: Between $1^{st}$ January 2002 and $31^{st}$ December 2011, 424 patients with MBC were treated in UMMC. A total of 186 out of 221 patients with de novo MBC who received first line palliative chemotherapy were analyzed. The mean age of patients in this study was 49.5 years (range 24 to 74 years). Biologically, ER status was negative in 54.4% of patients and Her-2 status was positive in 31.1%. A 5-flourouracil, epirubicin and cyclophosphamide (FEC) chemotherapy regimen was chosen for 86.6% of the cases. Most patients had multiple metastatic sites (58.6%). The main result of this study showed a FN rate of 5.9% and TRD rate of 3.2%. The median survival (MS) for the entire cohort was 19 months. For those with multiple metastatic sites, liver only, lung only, bone only and brain only metastatic sites, the MS was 18, 24, 19, 24 and 8 months respectively (p-value= 0.319). Conclusions: In conclusion, we surmise that FEC is a safe regimen with acceptable FN and TRD rates for de novo MBC.

Neuroprotective Effect of $NeuBo153^{\circledR}$ on Transient Focal Cerebral Ischemia in Rats ($NeuBo153^{\circledR}$의 중풍동물 모델에 대한 뇌신경 보호효과)

  • Bu, Young-Min;Oh, Se-Nam;Hwang, Man-Ki;Chung, Jin-Hee;Lee, Dae-Hee;Park, Young-Mee;Kim, Mi-Yon;Kim, Zhen-Hwa;Kim, Ho-Cheol
    • The Korea Journal of Herbology
    • /
    • v.21 no.2
    • /
    • pp.151-158
    • /
    • 2006
  • Objectives : The purpose of the present study is to observe the neuroprotective effect of the $NeuBo153^{\circledR}$ on transient focal cerebral ischemia in rats. Methods : $NeuBo153^{\circledR}$ was made by mixing the herbs, mainly the root of Panax ginseng, the root of Rehmannia glutinosa and Poria cocos, the stem bark of Acanthopanax senticosus, the root of Scutellaria baicalensis and Mel, and heating for 96 hours. Transient Focal cerebral ischemia (2 h of ischemia, 22 h of reperfusion) was induced by intraluminal suture method with SD rats. Sensory motor function was tested by rotarod test, prehensile traction test, beam balance test and foot fault test at 24 h after ischemia. The brain slices were stained by 2% 2, 3, 5-triphenyltetrazolium chloride and the infarct volume was measured by graphic analyzer at 24 h after ischemia. Results : $NeuBo153^{\circledR}$ treated group did not show significant differences compared with vehicle treated group in body temperature. Oral administration of $NeuBo153^{\circledR}$ reduced brain infarct volume by 29.7% compared with vehicle treated group. $NeuBo153^{\circledR}$ also showed protective effects on sensory motor functional deficits. Conclusion : $NeuBo153^{\circledR}$ treatment reduced brain damage and improved functional deficits induced by MCAo. It showed neuroprotective effects even when treatment was relayed 2 h after injury. Further research is required to evaluating long term functional recovery am accurate therapeutic range and mechanisms.

  • PDF

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.

Effect of Yikgeebohyul-tang (Yiqib$\check{u}$xu$\grave{e}$-tang) on Hair Regrowth and Cytokine Changes on Hair-Removed C57BL/6 Mice (익기보혈탕(益氣補血湯)이 C57BL/6 마우스의 육모(育毛)촉진 및 Cytokine 변화에 미치는 영향)

  • Hong, Jung-Ae;Song, Mi-Yeon;Choi, In-Hwa;Sohn, Nak-Won;Chung, Seok-Hee
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.138-152
    • /
    • 2010
  • Objective: Yikgeebohyul-tang (Yiqib$\check{u}$xu$\grave{e}$-t$\bar{a}$ng) is one of the representative prescriptions for invigoration of vitality and nourishing of the blood. This study was carried out to investigate the effects of Yikgeebohyul-tang (Yiqib$\check{u}$xu$\grave{e}$-t$\bar{a}$ng) on hair regrowth and cytokine changes in a shaving model of C57BL6 mice. Method: Five-week-old mice were acclimated for 1 week at a temperature between $21-23^{\circ}C{\acute{E}}$, 40-60% relative humidity, and 12h of a light/dark cycle before beginning of the experiment. There were two groups including normal saline (control) and a positive control of oral intake of Yikgeebohyul-tang (Yiqib$\check{u}$xu$\grave{e}$-t$\bar{a}$ng) extract (sample) in 18 female mice. The test compounds were topically treated once a day over 14 days. The hair regrowth was photographically and histologically determined during the experimental period of 14 days. Revelation of TGF-${\beta}1$ and EGF were also determined using immunohistochemistry. In addition to that, IFN-$\gamma$, IL-4 and IL-10 were determined in serum. Results: Hair regrowth in the sample group was promoted earlier and faster than the control group, as shown by concentrations of hairs and thick-hair ratio in the sample group. TGF-${\beta}1$ was not revealed in either control or sample group. EGF was strongly positive in out root sheath of some thick hair of the sample group. Serum IFN-$\gamma$ was significantly decreased in the sample group compared with the control group at 7 experimental days. However, it was not significantly decreased at 14 experimental days. Serum IL-4 was significantly increased in the sample group compared with the control group at 7 experimental days. However, it was not significantly decreased at 14 experimental days. Serum IL-10 was decreased in the sample group compared with the control group, but with no real statistical significance. Conclusion: These results suggest that Yikgeebohyul-tang (Yiqib$\check{u}$xu$\grave{e}$-t$\bar{a}$ng) has hair growth promoting activity and it can be used for treatment of alopecia. Also, these effects relate to EGF revelation of hair roots, a decrease in serum IFN-$\gamma$, and an increase of serum IL-4.

Expression of receptors of Vitamin D and cytokines in osteoclasts differentiated by M-CSF and ODF (Macrophage Colony-Stimulating Factor와 Osteoclast Differentiation Factor로 분화 유도된 생쥐 파골세포에서 Vitamin D 및 수종의 싸이토카인 수용체의 발현)

  • Seong, Soo-Mi;Um, Heung-Sik;Ko, Sung-Hee;Woo, Kyung-Mi;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.865-873
    • /
    • 2002
  • The primary cause of tooth loss after 30 years of age is periodontal disease. Destruction of alveolar bone by periodontal disease is done by bone resorbing activity of osteoclasts. Understanding differentiation and activation mechanism of osteoclasts is essential for controling periodontal disease. The purpose of this study is to identify the possible effects of Vitamin D and cytokines affecting osteoclasts and its precursor cells. Four to six week-old mice were killed and humerus, radius, tibia and femur were removed aseptically and washed two times with Hank's solution containing penicillin-streptomycin and then soft tissue were removed. Bone marrow cells were collected by 22 gauge needle. Cells were cultured in Hank's solution containing 1 mg/ml type II collagenase, 0.05% trypsin, 41mM EDTA. Supernatant solution was removed 5 times after 15 minutes of digestion with above mentioned enzyme solution, and remained bone particles were maintained in alpha-MEM for 15 minutes and $4^{\circ}C$ temperature. Bone particles were agitated for 1 minute and supernatant solution containing osteoclast precursor cells were filtrated with cell stainer. These separated osteoclast precursor cells were dispensed with 100-mm culture dish by $1{\times}10^7$ cells unit and cultured in ${\alpha}$- MEM containing 20 ng/ml recombinant human M-CSF, 30 ng/ml recombinant human soluble osteoclast differentiation factor and 10% fetal calf serum for 2 and 7 days. Total RNA of osteoclast precursor cells were extracted using RNeasy kit. One ${\mu}g$ of total RNA was reverse transcribed in $42^{\circ}C$ for 30 minutes using SuperScriptII reverse transcriptase. Expression of transcribed receptors of each hormone and cytokine were traced with 1 ${\mu}l$ of cDNA solution by PCR amplification. Vitamin D receptor WAS found in cells cultured for 7 days. TNF-${\alpha}$ receptor was found in cells cultured for 2 days and amount of receptors were increased by 7 days. IL-1 type I receptor was not found in cells cultured 2 and 7 days. But, IL-1 receptor type II was found in cells cultured for 2 days. TGF-${\alpha},{\beta}$type I receptor was found in cells cultured 2 and 7 days, and amount of receptors were increased by 7 days of culture. These results implies Vitamin D and cytokines can affect osteoclasts directly, and affecting period in differentiation cycle of osteoclasts is different by Vitamin D and cytokines.