Browse > Article

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK  

Lee, Young-Jae (Department of Dental Science, Graduate School, Chonnam National University)
Vang, Mong-Sook (Department of Dental Science, Graduate School, Chonnam National University)
Yang, Hong-So (Department of Dental Science, Graduate School, Chonnam National University)
Park, Sang-Won (Department of Dental Science, Graduate School, Chonnam National University)
Park, Ha-Ok (Department of Dental Science, Graduate School, Chonnam National University)
Lim, Hyun-Pil (Department of Dental Science, Graduate School, Chonnam National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.45, no.4, 2007 , pp. 431-443 More about this Journal
Abstract
Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.
Keywords
Rigidity; Castability; Designs; Titanium Framework;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kratochvil FJ. Maintaining supporting structures with a removable partial prosthesis. J Prosthet Dent 1971:25:167-74   DOI
2 Baltag I, Watanabe K, Kusakari H, Miyakawa O. Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design. J Prosthet Dent 2002;88: 151-8   DOI   ScienceOn
3 Morris HF, Manz M, Stoffer W. Casting alloys: the materials and the clinical effects. Advances in Dental research 1992:24:414
4 Wakabayashi N, Ai M. A short-term clinical follow-up study of superplastic titanium alloy for major connectors of removable partial dentures. J Prosthet Dent 1997;77:583-7   DOI   ScienceOn
5 Davis Henderson. Major connectors. Dental Clinics of North America 1973; 17:661-78   PUBMED
6 Au AR, Lechner SK, Thomas CJ. Mori T. Chung P. Titanium for removable partial dentures (III): 2-year clinical follow-up in an undergraduate programme. J Oral Rehabil 2000;27:979-85   DOI   ScienceOn
7 Mori T, Togaya T, Jean-Louis M, Yabugami M. Titanium for removable dentures. J. Laboratory procedures. J Oral Rehabil 1997; 24: 338-41   DOI   ScienceOn
8 Bezzon OL. Pedrazzi H. Zaniquelli O, da Silva TB. Effect of casting technique on surface roughness and consequent mass loss after polishing of Ni-Cr and Co-Cr base metal alloys: A comparative study with titanium. J Prosthet Dent 2004:92:274-7   DOI   ScienceOn
9 Srimaneepong V. Yoneyama T, Wakabayashi N. Deformation properties of Ti-6Al-7Nb alloy castings for removable partial denture frameworks. Dent Mater J 2004;23:497-503   DOI   PUBMED   ScienceOn
10 Tsolka P, Altay OT. Preiskel HW. The effect of the major connector on abutment tooth and denture base movement: An in vitro study. The international Journal of Pros 1990;3:545-9
11 Bridgeport DA. Brantley WA, Herman PF. Cobalt-chromium and nickel-chromium alloys for removable prosthodontics. Part 1: Mechanical properties. J Prosthodont 1993:2:144-50   DOI   ScienceOn
12 Wagner AG, Traweek FC. Comparison of major connectors for removable partial dentures. J Prosthet Dent 1982;47:242-4   DOI   ScienceOn
13 Ben-Ur Z. Miliritsky E. Gorfil C. Brosh T. Stiffness of different designs and cross-sections of maxillary and mandibular major connectors of removable partial dentures. J Prosthet dent 1999;81:526-32   DOI   ScienceOn
14 Wang RR. Fenton A. Titanium for prosthodontics applications: A review of the literature. Quintessence Int 1996:27:401-8   PUBMED
15 Barbenel JC. Design of partial denture components. I. Middle palatal bars. J Dent Res 1971:50:586-9   DOI   PUBMED   ScienceOn
16 Hindles GW. Stress analysis in distal extension partial dentures. J Prosthet Dent 1987:7:197-205
17 Matsumoto M, Goto T. Lateral force distribution in partial denture design. J Dent Res 1970:29:359-64
18 Bridgeman JT, Marker VA, Hummel SK, Benson BW, Pace LL. Comparison of titanium and cobalt-chromium removable partial denture clasps. J Prosthet Dent 1997;78:507-16
19 Reitz PV, Sanders JL, Caputo AA. A photoelastic study of a split palatal major connector. J Prosthet Dent 1984:51:19-23   DOI   ScienceOn
20 Vidovic Y, Chung HG, Mori T. Enhancement of a titanium denture frame model: mold temperature and spruing factors. Dent Mater J 1995:14:256-62   DOI   PUBMED   ScienceOn
21 Fenton AH, Afzali D. Accuracy of titanium RPD castings. Journal of Dental Research. abstract, 166
22 LaVera AM, Krol AJ. Selection of a major connector for the extension-base removable partial denture. J Prosthet Dent 1973;30:102-6   DOI   ScienceOn
23 Green LK. Hondrum SO. The effect of design modifications on the torsional and compressive rigidity of U-shaped palatal major connectors. J Prosthet Dent 2003: 89:400-40   DOI   ScienceOn
24 Rodrigues RC. Ribeiro RF. de Mattos Mda G. Bezzon OL. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures. J Prosthet Dent 2002:88:290-6   DOI   ScienceOn
25 Ali M. Nairn RI. Sherriff M. Waters NE. The distortion of cast cobalt-chromium alloy partial denture frameworks fitted to a working cast. J Prosthet Dent 1997; 78;382-91
26 Jang KS, Youn SJ, Kim YS. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks. J Prosthet Dent 2001:86:93-8   DOI   ScienceOn
27 Thomas CJ, Lechner S, Mori T. Titanium for removable partial dentures. II. Two-year clinical observations. J Oral Rehabil 1997:24:414-8   DOI   ScienceOn
28 Ozkan P. Aydin AK. Comparison of Deformation by stereophotogrammetry of Various kinds of major connectors in maxillary Kennedy Class I removalble partial dentures. Int J Prosthodont 2001:14:71-6   PUBMED
29 Ben-Dr Z, Matalon S, Aviv I, Cardash HS. Rigidity of major connectors when subjected to bending and torsion forces. J Prosthet Dent 1989:62:557-62   DOI   ScienceOn
30 Kaires AK. Effect of partial denture design on bilateral force distribution. J Prosthet Dent 1956:6:373-85   DOI
31 Chan D. Guillory V. Blackman R, Chung KH. The effects of sprue design on the roughness and porosity of titanium castings. J Prosthet Dent 1997:78:400-4   DOI   ScienceOn
32 Cecconi BT. Koeppen RG. Phoenix RD. Cecconi ML. Casting titanium partial denture frameworks: A radiographic evaluation. J Prosthet Dent 2002:87:277-83   DOI   ScienceOn