• Title/Summary/Keyword: oral and maxillofacial surgery

Search Result 4,540, Processing Time 0.038 seconds

The Content Analysis of the Textbooks of Dental Clinical Course (치과임상교과목 교재에 대한 내용분석)

  • Lee, Sun-Mi;Yoo, Jung-Sook;Ahn, Se-Youn;Lim, Mi-Hee;Han, Ji-Youn;Jun, Mi-Kyoung;Lee, Hyun-Ok;Won, Young-Soon
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.272-279
    • /
    • 2015
  • This study was conducted to provide baseline data which could suggest a direction of role based efficient integrated clinical education by avoiding duplicate of contents through analyzing clinical courses. Among the 7 clinical courses, orthodontics and periodontology were the most published subjects which were published in 5 kinds of books and dental materials was the least published subject which was published in 2 kinds of books on investigation of overlapping contents based on titles that appeared on chapters and verses of all textbooks for clinical courses. Dental implant was covered in 4 subjects such as oral maxillofacial surgery, prosthodontics, periodontology and dental materials which was the most number. Other overlapping contents were restoration treatment, occlusion and malocclusion, temporomandibular joint diseases, anesthesia sedation, tooth trauma, systemic disease and dental treatment, dental casting, isolation techniques, tooth bleaching, pulp protection, gingivitis periodontitis, tooth development, etc. Reviews of textbooks of clinical courses should be conducted in a detailed manner by systematic, various studies in order to improve quality of the textbooks.

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients (자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구)

  • Kwon, Min-Jung;Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2011
  • This prospective study was designed to compare clinical outcomes of immediately loaded implant with delayed loaded implant in partially posterior edentulous patients. For test group, 42 GS III (Osstem, Korea) implants in 17 patients were loaded within 48 hours after the placement. Control group was 27 implants in 15 patients loaded at $2.6{\pm}1.7months$ from the placement surgery. Before loading, primary stability was evaluated by ISQ value. Clinical symptoms, mobility, soft tissue state was evaluated at baseline, 3 months, 6 months and 12 months of loading. Marginal bone level change was also measured with periapical radiographs. Mann-Whitney test (${\alpha}$=0.05) and repeated measured ANOVA (${\alpha}$=0.05) was used for marginal bone level change between two groups. At the baseline, mean ISQ value of test group and control group was $80.3{\pm}7.1$ and $69{\pm}17$ respectively. Test group showed 95.23% of success rate and 100% of control group was successful. At 3 and 6months of loading, significantly more bone resorption was observed in test group than in control group (p<0.05). However, there was no significant difference in the bone level change at 12months of loading between two groups (p>0.05). Marginal bone level change showed no significant difference with gender and location (p>0.05). Within the limitation of this study, when primary stability was obtained, immediate loading of GS III implant at posterior region could be predictable treatment option.

A SURVEY OF SEDATION PRACTICES IN THE KOREAN PEDIATRIC DENTAL OFFICE (어린이의 치과치료시 약물에 의한 진정요법 사용에 대한 실태조사)

  • An, So-Youn;Choi, Byung-Jai;Kwak, Ji-Youn;Kang, Jeong-Wan;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.444-453
    • /
    • 2005
  • Sometimes the dentists encounter a child who can not be treated with traditional behavior management techniques (for example, reward, restraint, Tell-Show-Do, familialization). In such a case, the dentists use sedation technique. Recently, in Korea, the use of sedation by pediatric dentists is increased. But, the guideline and survey of sedation is very insufficient. Now, we need a survey of sedation practice in Korea. We carried out research on the actual condition about sedation with a questionaire to pediatric dentists in Korea. Followings are the conclusions 1. Sixty six percent of pediatric dentists use sedative agents in their practice. In this study, using sedation shows an increase as compared with the past. 2. Determinative factors of using sedation were orderly behavior management, number of visiting, guidian's opinion, amount of treatment, general condition. 3. Distribution of ages in patients sedated with agents was orderly 3 years, 4-5 years, under 2 years, 6-10 years, more than 10 years. 4. Particular sedative drugs were chloral hydrate 60-70mg/kg, hydroxyzine 10-40mg/kg(25mg/kg), and oral route was the most favorable route. 5. Observation of skin and nail color, pulse oximeter were the most frequently utillized monitoring method during sedation. 6. Only fifty six percent of pediatric dentists complete the cardiopulmonary resuscitation course.

  • PDF

Transfer of Isolated Mitochondria to Bovine Oocytes by Microinjection (미세주입을 이용한 난자로의 분리된 미토콘드리아 전달)

  • Baek, Sang-Ki;Byun, June-Ho;Kim, Bo Gyu;Lee, A ram;Cho, Young-Soo;Kim, Ik-Sung;Seo, Gang-Mi;Chung, Se-Kyo;Lee, Joon-Hee;Woo, Dong Kyun
    • Journal of Life Science
    • /
    • v.27 no.12
    • /
    • pp.1445-1451
    • /
    • 2017
  • Mitochondria play a central role in energy generation by using electron transport coupled with oxidative phosphorylation. They also participate in other important cellular functions including metabolism, apoptosis, signaling, and reactive oxygen species production. Therefore, mitochondrial dysfunction is known to contribute to a variety of human diseases. Furthermore, there are various inherited diseases of energy metabolism due to mitochondrial DNA (mtDNA) mutations. Unfortunately, therapeutic options for these inherited mtDNA diseases are extremely limited. In this regard, mitochondrial replacement techniques are taking on increased importance in developing a clinical approach to inherited mtDNA diseases. In this study, green fluorescence protein (GFP)-tagged mitochondria were isolated by differential centrifugation from a mammalian cell line. Using microinjection technique, the isolated GFP-tagged mitochondria were then transferred to bovine oocytes that were triggered for early development. During the early developmental period from bovine oocytes to blastocysts, the transferred mitochondria were observed using fluorescent microscopy. The microinjected mitochondria were dispersed rapidly into the cytoplasm of oocytes and were passed down to subsequent cells of 2-cell, 4-cell, 8-cell, morula, and blastocyst stages. Together, these results demonstrate a successful in vitro transfer of isolated mitochondria to oocytes and provide a model for mitochondrial replacement implicated in inherited mtDNA diseases and animal cloning.

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement (임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구)

  • Choi, Yu-Sung;Kim, Eun-Kyung;Kim, Se-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the changes in bone density and reduction of time consumed for osteogenesis by $PostPlant^{TM}$ Calcium and to find out efficacy of $PostPlant^{TM}$ Calcium by comparing the group prescribed with $PostPlant^{TM}$ Calcium with the group without $PostPlant^{TM}$ Calcium prescription. Material and methods: The experimental group of 18 patients with 25 dental implant placement and the control group of 7 patients with 9 dental implant placement were randomly selected from the patients who visited prosthetic department of Dankook University Dental Hospital since July, 2006 (IRB Number ; 20060710). The experimental group was instructed to take $PostPlant^{TM}$ Calcium for 6 months after the implant surgery while the control group was instructed not to. Both experimental and control group were assigned for measurement using $Osstell^{TM}$ Mentor and $Periotest^{(R)}$ and radiographic examination was performed using specifically manufactured Aluminum Step Wedge. The results were compared and analyzed. Results: 1. According to the $Osstell^{TM}$ Mentor measurement, both the experimental and control group showed increase in values as time elapses and the experimental group showed significantly higher rate of increase (P < .05). 2. According to the $Periotest^{(R)}$ measurement, both the experimental and control group showed decrease in values as time elapses. In addition, greater decrease can be seen in the experimental group but no statistical significance was found. 3. By examining the radiographic images, both the experimental and control group showed tendency of increase in bone density. In addition, greater increase can be seen in the experimental group but no statistical significance was found. Conclusion: Clinically, taking $PostPlant^{TM}$ Calcium medicine for a long period of time after implant placement is expected for a better prognosis.

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

The expression of MMP-1, -8, and -13 mRNA in the periodontal ligament of rats during tooth movement with cortical punching (백서의 치아이동 시 피질골 천공이 치주조직의 MMP-1, -8, -13 mRNA의 발현에 미치는 영향)

  • Gwack, Choon;Kim, Seong-Sik;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Deok;Jun, Eun-Sook;Park, Mi-Hwa
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.187-201
    • /
    • 2008
  • Objective: The aim of this study was to determine whether cortical punching stimulates the expression of matrix metalloproteinase-1, -8, and -13 in orthodontic tooth movement in rats. Methods: A total of 32 male sprague-dawley rats at 15 weeks old were divided into two groups of 16 rats each, to form the tooth movement with cortical punching (TMC) group and tooth movement only (TM) group. A total of 20 gm of orthodontic force was applied to rat incisors to cause experimental tooth movement. Cortical punching was performed on the palatal side near the central incisor with a 1.0 mm width microscrew in the TMC group. The duration of tooth movement was 1, 4, 7, and 14 days. Results: Measurements of the mRNA expression were selected as the means to determine the identification of expression of MMP-1, -8, and -13. In the TMC group, the expression of collagen type I was greater than that of the TM group from day 4 to day 14. Expression of TIMP-1 in the TM group was greater than that of the TMC group in the pressure side of PDL and alveolar bone cell at day 4. In the TMC group, TIMP-1 was expressed at the osteoclast, but not at the tooth surface of the TM group at day 14, Maximum induction of the mRNA of MMP-1 was observed on day 4 in the TMC group, but it was observed on day 7 in the TM group. MMP-8 mRNA of the TMC group was twice greater than that of the TM group at f days. In the TMC group, maximum induction of MMP-13 mRNA was observed on day 1. Conclusions: These findings suggested that cortical punching can stimulate remodeling of PDL and alveolar bone connective tissues during experimental orthodontic tooth movement in rats.

Improvement of Cell Viability Using a Rho-associated Protein Kinase (ROCK) Inhibitor in Human Dental Papilla derived Single-induced Pluripotent Stem Cells (ROCK 억제제를 통한 사람 치유두 조직 유래 단일 사람 유도만능줄기세포의 생존성 향상)

  • Shim, Yoo-Jin;Kang, Young-Hoon;Kim, Hyeon-Ji;Kim, Mi-Jeong;Lee, Hyeon-Jeong;Son, Young-Bum;Lee, Sung-Ho;Jeon, Byeong-Gyun
    • Journal of Life Science
    • /
    • v.29 no.8
    • /
    • pp.895-903
    • /
    • 2019
  • The aim of the present study was to improve the cell viability of human dental papilla derived single-induced pluripotent stem cells (iPSCs) using a Rho-associated protein kinase (ROCK) inhibitor, Y-27632. The iPSCs were produced using an episomal plasmid-based reprogramming method. After cell separation using trypsin, the iPSCs were treated with 0, 0.5, 1, 2.5, 5, 7.5, or $10{\mu}M$ Y-27632 for 5 d. Cell viability increased significantly following the $5{\mu}M$ Y-27632 treatment (p<0.05). When the iPSCs were exposed to medium containing $10{\mu}M$ Y-27632 for 0, 1, 2, 3, 4, and 5 d, the cell viability rate increased significantly in accordance with the cell viability rate (p<0.05). To evaluate the effect of the Y-27632 treatment on stemness characteristics, the expression of stem cell-specific transcripts and telomerase activity were investigated in the iPSCs treated with $10{\mu}M$ Y-27632 for 5 d. The expression levels of stem cell-specific transcripts, such as OCT-4, NONOG, and SOX-2, and telomerase activity were not significantly different in the iPSCs treated with $10{\mu}M$ Y-27632 as compared with those of untreated control iPSCs (p>0.05). Taken together, the results demonstrated that cell viability can be improved by treatment with the ROCK inhibitor Y-27632, without losing iPSC stemness characteristics.