• Title/Summary/Keyword: optimum use time

Search Result 452, Processing Time 0.029 seconds

A Study on the Properties and the Applying method of the HWANGTO GUDUL in View of an Environmental Ecological House (환경생태주택의 관점에서 본 황토구들의 일반적 특성과 적용)

  • Kim, June-Bong;Rhee, Shin-Ho;Yeo, Min;Jang, Moon-Ki
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.63-70
    • /
    • 2002
  • This study aims to provide the fundamental date of HUANGTO GUDUL for applying to current house heating system. It has been used as a traditional heating system in Korea for a long time and disappeared in the course of industrialization in Korea last a few decades and these days is tend to be widely adopted as house heating system. Even though it is known that the traditional heating system of HUANGTO GUDUL is good for ecological environment house and a kind of the natural friendly heating system for optimum residential heating environment, there are few systematic researches and analysed data of it. In order to analyse the characteristics of HUANGTO GUDUL, the existing materials of it's historical change was studied. And the architectural prospects of the use of GUDUL on the point of view of environmental ecology. The data of relationship between the mechanic properties and the workability of GUDUL materials and the environmental index such as the heating environment, relative humidity, and deodorization ratio and so on. And the heating effectiveness of GUDUL was compared with existing modem materials by experimental analysis. The results stated above can be grafted architecture and will be offered the optimum heating environment.

The Effect of L-cysteine, EDTA in Papain Treatment of Wool Fabrics (양모직물에 파파인 처리 시 L-cysteine, EDTA의 영향)

  • Sung, Jong-Mi;Song, Wha-Soon;Kim, In-Young
    • Textile Coloration and Finishing
    • /
    • v.20 no.2
    • /
    • pp.9-18
    • /
    • 2008
  • Wool has excellent properties, such as heat retention, absorbency, and elasticity, but it has a disadvantage in washability because the fabric will felt and shrink greatly. Felting causes the interlocking of the fiber surface scales with one another. Therefore, the studies on wool finishing have been focused on shrink proofing. Precedent researches on wool shrink proofing are mostly on eco-friendly method. using enzyme. The purpose of this study is to examine the effect of L-cysteine, EDTA in papain treatment of wool fabrics. The specific contents of study are as follows. Depending on pH, temperature, treatment time, enzyme concentration and L-cysteine, EDTA concentration, weight loss, tensile strength, whiteness, SEM were examined. Each papain treatment conditions depending on L-cysteine, EDTA were optimized from these properties. Papain had very low activation without activators. The optimum conditions of papain treatment were pH 7.5, temperature $75^{\circ}C$, time 30minutes(L-cysteine), 180minutes(EDTA) and papain concentration 5%(o.w.f.). In the use of papain 5%(o.w.f.), the activators optimum concentration was L-cysteine 2%(o.w.f.), EDTA 7%(o.w.f.)

Adaptive Resource Allocation for Traffic Flow Control in Hybrid Networks

  • Son, Sangwoo;Rhee, Byungho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.1
    • /
    • pp.38-55
    • /
    • 2013
  • Wireless network systems provide fast data transmission rates and various services to users of mobile devices such as smartphones and smart pads. Because many people use high-performance mobile devices, the use of real-time multimedia services is increasing rapidly. However, the preoccupation of resources by real-time traffic users is causing harm to other services-for example, frequent call interference, lowered service quality, and poor network performance. This paper suggests a resource allocation algorithm for effective traffic service support in a hybrid network. The main objective is to obtain an optimum value of data rates by comparing user requirements with the amount of resources that can be allocated. A new mechanism based on Adaptive-Quality of Service (QoS) and a monitoring system based on Queue-Aware are proposed. Adaptive-QoS supports effective resource control according to the type of traffic service, and the monitoring system based on Queue-Aware measures the amount of resources in order to calculate the maximum that can be allocated. We apply our algorithm to a test system and use Qualnet 4.5.1 to evaluate its performance.

Disinfection of E. coli Using Electro-UV Complex Process: Disinfection Characteristics and Optimization by the Design of Experiment Based on the Box-Behnken Technique (전기-UV 복합 공정을 이용한 E. coli 소독 : 실험계획법중 박스-벤켄법을 이용한 소독 특성 및 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.889-900
    • /
    • 2010
  • The experimental design and response surface methodology (RSM) have been applied to the investigation of the electro-UV complex process for the disinfection of E. coli in the water. The disinfection reactions of electro-UV process were mathematically described as a function of parameters power ($X_1$), NaCl dosage ($X_2$), initial pH ($X_3$) and disinfection time ($X_4$) being modeled by use of the Box-Behnken technique. The application of RSM using the Box-Behnken technique yielded the following regression equation, which is an empirical relationship between the residual E. coli number and test variables in actual variables: Ln (CFU) = 23.57 - 0.87 power - 1.87 NaCl dosage - 2.13 pH - 2.84 time - 0.09 power time - 0.07 NaCl dosage pH + 0.14 pH time + 0.03 $power^2$ + 0.47 NaCl $dosage^2$ + 0.20 $pH^2$+ 0.33 $time^2$. The model predictions agreed well with the experimentally observed result ($R^2$ = 0.9987). Graphical response surface and contour plots were used to locate the optimum point. The estimated ridge of maximum response and optimal conditions for the E. coli disinfection using canonical analysis was Ln 1.06 CFU (power, 15.40 W; NaCl dosage, 1.95 g/L, pH, 5.94 and time, 4.67 min). To confirm this optimum condition, the obtained number of the residual E. coli after three additional experiments were Ln 1.05, 1.10 and Ln 1.12. These values were within range of 0.62 (95% PI low)~1.50 (95% PI high), which indicated that conforming the reproducibility of the model.

Monitoring on Heating Condition and Enzyme Treatment Condition for Manufacture of Oriental Melon Concentrate (참외 농축액 제조를 위한 가열 및 효소 처리조건 모니터링)

  • 이기동;권승혁;이명희;김숙경;주길재;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.5
    • /
    • pp.905-910
    • /
    • 2004
  • This study was carried out to observe the change of oriental melon juice quality during manufacture by heating condition and enzyme treatment. To use over-production oriental melon effectively, oriental melon juice was prepared with change of heating temperature and heating time. The heating conditions for minimum filtration time were 98.57$^{\circ}C$ and 11.29 min. The optimum conditions Predicted for separation ratio of clear solution, filtration time and browning color intensity of oriental melon juice were 98$^{\circ}C$, 13 min. In the pectin-degrading enzyme treatment test, turbidity showed minimum value in 4.40 mg%(pectin-degrading enzyme content), 39.72 mg% (gelatin content) and 24.09 min (treatment time).Browning color intensity showed minimum value in 9.33 mg% (pectin-degrading enzyme content),44.70 mg% (gelatin content) and 115.56 min (treatment time). The optimum conditions predicted for turbidity and browning color intensity of oriental melon concentration Juice were 6.6 mg% (pectin-degrading enzyme content), 33.6 mg% (gelatin content) and 70 min (treatment time).

Removal of toxic hydroquinone: Comparative studies on use of iron impregnated granular activated carbon as an adsorbent and catalyst

  • Tyagi, Ankit;Das, Susmita;Srivastava, Vimal Chandra
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.474-483
    • /
    • 2019
  • In this study, iron (Fe) impregnated granular activated carbon (Fe-GAC) has been synthesized and characterized for various properties. Comparative studies have been performed for use of Fe-GAC as an adsorbent as well as a catalyst during catalytic oxidation of hydroquinone (HQ). In the batch adsorption study, effect of process parameter like initial HQ concentration ($C_o=25-1,000mg/L$), pH (2-10), contact time (t: 0-24 h), temperature (T: $15-45^{\circ}C$) and adsorbent dose (w: 5-50 g/L) have been studied. Maximum HQ adsorption efficiency of 75% was obtained at optimum parametric condition of: pH = 4, w = 40 g/L and t = 14 h. Pseudo-second order model best-fitted the HQ adsorption kinetics whereas Langmuir model best-represented the isothermal equilibrium behavior. During oxidation studies, effect of various process parameters like initial HQ concentration ($C_o:20-100mg/L$), pH (4-8), oxidant dose ($C_{H2O2}:0.4-1.6mL/L$) and catalyst dose (m: 0.5-1.5 g/L) have been optimized using Taguchi experimental design matrix. Maximum HQ removal efficiency of 83.56% was obtained at optimum condition of $C_o=100mg/L$, pH = 6, $C_{H2O2}=0.4mL/L,$ and m = 1 g/L. Overall use of Fe-GAC during catalytic oxidation seems to be a better as compared to its use an adsorbent for treatment of HQ bearing wastewater.

A Study on the Application of Temperature Feedback Aeration Method for Composting of Municipal Solid Wastes (효율적 퇴비화를 위한 온도제어 공기공급방식의 적용에 관한 연구)

  • Kim, Byung-Tae;Kim, Jung-Wk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.3-18
    • /
    • 1994
  • Municipal solid wastes in Korea have physical and chemical properties suitable for composting, but composting has had little practical use in solid waste disposal until now because of a lack of understanding of process control. For practical use of composting, process control must be capable of maintaining good product quality while large quantities are composted in a short period of time. Ventilation control to maintain optimum temperature(Temperature Feedback Aeration Method) is reported to be convenient to operate. The purpose of this study is to analyze process efficiency and optimum temperature in the temperature feedback aeration method for composting of municipal solid wastes. The results of this study show that degradation and drying of substrate in the temperature feedback aeration method are higher than those in the constant aeration method. And the optimum temperature range for composting of solid wastes appears to be $50{\sim}54^{\circ}C$.

  • PDF

A Study on the Recreation Carrycity of Lawn Areas in Parks(II) -Estimation of Ecological Carrying Capacity based on User Behavior- (공원잔디공간의 『레크레이션』수용능력에 관한 연구(II) -잔디공간 의 이용행태 분석 및 생태적 수용능력의 확정-)

  • 엄붕훈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.20 no.2
    • /
    • pp.1-17
    • /
    • 1992
  • This study was carried out to estimate the recreation carrying capacity of lawn areas in parks. Recreation carrying capacity in this study is composed of two parts, ecological carrying capacity and psychological carrying capacity. As the second part, this apper deals with the estimation of ecological carrying capacity based on user behavior. The study sites were located at Bomun Resort Complex in Kyungju, Korea. And the major species of the lawn areas was Zoysia japonica. The major results ar summarized as follows: 1. The mean numbers of user for the investigation days of peak season, were estimated as 792 people for the lawn area of Doturag World, and 588 people for Seorabul Plaza. The mean use time by user were 163 minutes and 197 minutes for each site. The weighted mean use time by each activity type(passive, active, and strolling) were estimated as 85 minutes, 45 minutes, and 50 minutes, respectively. 2. Forty kinds of diverse active recreation activities were classified into six types of activity categories. Male adults preferred "sports type" activities, whereas female adults and juveniles preferred "play type" activities. 3. Ecological carrying capacity for each level was estimated as 40.7㎡/man for optimum carrying capacity. And these values were calculated on the basis of total treading areas and treading time criteria for each carrying capacity level.

  • PDF

A Study on the Preparation of the Fly ash Adhesion-Activated Carbon and on the Removal of Heavy Metals (석탄회부착활성탄의 제조 및 중금속 제거에 관한 연구)

  • 문옥란;신대윤;고춘남
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • This study was aimed ultimately to develop an adsorption process treating heavy metal wastewater by utilizing activated carbon using flyash. The affecting factors in adsorption process on heavy metal by flyash adhesion-activated carbon are s follows. Factors such as pH, and quality of activated carbon, and reaction time made batch adsorption isotherm described adsorption capacity was made use of the investigation to evaluate adsorptive possibility of heavy metal.As the results of this study, H ion has influence on adsorption of heavy metal if pH is low. As reaction time is transformed, factors such as optimum reaction time is taken into consideration an adsorptive process of heavy metal because an adsorption and a reduction process occur. Adsorption isotherm of adhesion-activated carbon was generally obeyed to Freundlich formular than Langmuir formular and Freundlich constant, l/n were obtained in the range of 0.1~0.5.

  • PDF

A Study on the UV Degradation Characteristics of FRP by Plasma Surface Modification (플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구)

  • Hwang, Myung-Hwan;Lim, Kyung-Bum
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.122-126
    • /
    • 2006
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 Torr of system pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.