• Title/Summary/Keyword: optimum operation

Search Result 1,185, Processing Time 0.033 seconds

A Study on the Multi-level Optimization Method for Heat Source System Design (다단계 최적화 수법을 이용한 열원 설비 설계법에 관한 연구)

  • Yu, Min-Gyung;Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.299-304
    • /
    • 2016
  • In recent years, heat source systems which have a principal effect on the performance of buildings are difficult to design optimally as a great number of design factors and constraints in large and complicated buildings need to be considered. On the other hand, it is necessary to design an optimum system combination and operation planning for energy efficiency considering Life Cycle Cost (LCC). This study suggests a multi-level and multi-objective optimization method to minimize both LCC and investment cost using a genetic algorithm targeting an office building which requires a large cooling load. The optimum method uses a two stage process to derive the system combination and the operation schedule by utilizing the input data of cooling and heating load profile and system performance characteristics calculated by dynamic energy simulation. The results were assessed by Pareto analysis and a number of Pareto optimal solutions were determined. Moreover, it was confirmed that the derived operation schedule was useful for operating the heat source systems efficiently against the building energy requirements. Consequently, the proposed optimization method is determined by a valid way if the design process is difficult to optimize.

Turbidity Treatment of TiO2 Wastewater by Electrocoagulation/flotation Process (전기응집/부상 공정을 이용한 TiO2 폐수의 탁도 제거)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • The separation of $TiO_2$ wastewater carried out by an electrocoagulation/flotation process, which had various operating parameters. The effect of electrode material (aluminum and four dimensionally stable electrode), applied current (0.07~0.5 A), electrolyte concentration (0~1 g/L), solution pH (3~11), initial turbidity (1000~20000 NTU) and suspended solid concentration (5000~25000 mg/L) were evaluated. Turbidity removal efficiency of the soluble anode (aluminum), which could produce metal ions, was higher than that of the dimensionally stable electrode. Considering operation time, turbidity removal and electric power, optimum current was 0.19 A. The more NaCl dosage was high, the less electric power was required. However, optimum NaCl concentration was 0.125 g/L considered removal efficiency, operation time and cost. Initial $TiO_2$ concentration did not affected turbidity removal on the electrocoagulation/flotation operation. The electrocoagulation/flotation process was proved to be a very effective separation method in the removal of $TiO_2$ from wastewater.

Ideal MHD Beta Limit for Optimum Stable Operation of Axisymmetric Tokamak Reactor with a Circular Cross Section (원형 단면을 가진 축대칭형 토카막 핵융합로의 최적운전을 위한 이상적 자기유체역학 안전성을 유지하는 베타값의 최대한계)

  • Lee, Hyoung-Koo;Hong, Sang-Hee
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.32-39
    • /
    • 1989
  • A method for determining the optimum ideal MHD $\beta$limit and the operation conditions is presented for an axisymmetric tokamak reactor with a circular cross section. The $\beta$limit is calculated under the constraints of ideal MHD instability criteria with varying the operation conditions which depend on the toroidal current density distributions. Semiempirical laws deduced from experimental observations are used for the toroidal current density distributions. Analytic derivations of various equations required to determine the $\beta$limit are carried out from the empirical equations. Various distributions of the $\beta$limit are obtained by the numerical calculations for different distributions of the toroidal current density. The resulting values of the maximum $\beta$limited by ideal MHD instabilities are expressed by a scaling law in terms of the tokamak geometry and the safety factor.

  • PDF

An Analysis of Optimum Transmission Range in MANETs under various Propagation Models (다양한 전파 환경 하에서 MANET 최적 통달거리 분석)

  • Choi, Hyungseok;Lee, JaeYong;Kim, ByungChul
    • Journal of Internet Computing and Services
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • This paper presents an analytical method for finding the optimum transmission range in mobile ad hoc networks(MANETs). The results are particularly useful for the operation of military networks, as the transmission range affects the throughput, delay, and battery consumption. Plus, the proposed method allows the optimum transmission range to be determined in advance when deploying combatants with mobile terminals. And we analyze the battery life-time and the optimum transmission range under various propagation scenarios based on Hata propagation model. The proposed method obtains the optimum transmission range in a MANET based on the operational conditions.

The Optimum Control Study for Improving Efficiency of the Small Hydropower Generation in Water Pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with 00 hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

A Study on the Pretreatment of Municipal Landfill Leachate by Electrolysis (전해처리에 의한 매립지 침출수의 전처리에 관한 연구)

  • 이병인;황순홍
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.417-425
    • /
    • 1994
  • Leachate from municipal landfill site is known to be hard to treat because it commonly contains various toxic material and heavy metals. In addition, portions of biodegradable organic substances in leachate are decreasing in the course of wastes stabilization, which is one of the critical reason for inefficient biological treatment at the end stage of landfill site operation. So this study was conducted to examine the feasibility of municipal lanuill leachate pretreatment using electrolysis. The optimum electrode combination was made. The optimum electrode combination was found to be lead and graphite.

  • PDF

Competitive Generation for Genetic Algorithms

  • Jung, Sung-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.86-93
    • /
    • 2007
  • A new operation termed competitive generation in the processes of genetic algorithms is proposed for accelerating the optimization speed of genetic algorithms. The competitive generation devised by considering the competition of sperms for fertilization provides a good opportunity for the genetic algorithms to approach global optimum without falling into local optimum. Experimental results with typical problems showed that the genetic algorithms with competitive generation are superior to those without the competitive generation.

Characteristics Analysis of Stabilizing Operation of Photovoltaic Inverter (태양광 발전용 인버터의 안정화 운전 특성해석)

  • Cho, G.B.;Kim, H.S.;Yu, G.J.;Song, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.742-745
    • /
    • 1993
  • In this paper, instantaneous current tracking control inverter is applied to photovoltaic system and then optimum operating area is described by state space average method for optimum design of maximum output control. Also control system is realized by DSP and excellence of system shows the effectiveness of inverter system using the instantaneous control method.

  • PDF

Development and Economic Effect of Integrated Optimum Operation System using Wide Area Energy (광역에너지이용 통합 최적화 운전 시스템 개발 및 경제적 효과)

  • Lee, Hoon;Kim, Lae-Hyun;Chang, Won-Seok
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.221-229
    • /
    • 2009
  • This study develops the optimized operation program which enables effective and economic operation between individual and connected branch offices by analyzing the current status and influential indicators of district heating companies' capital branch offices. Accordingly, the study examines the efficiency of optimized operation program. In doing so, this study has diagnosed and analyzed various factors, such as boilers, pumps, and relevant tags (temperature, pressure, fuel amount) through investigation of individual branch offices, and finally succeeded in developing wide-ranging data base by factor covering one-year time period. Additionally, after running the optimized operation program, different branch offices, optimum preference has turned out "incinerator receiving heat from KEPCO>CHP >PLBs>PLBw." Meantime, except the connected offices, there has been no big difference between actual and optimum operation program in branch offices. Meanwhile, the integrated optimum operation program has made it possible the most optimal result only via the connecting supply and demand heat without changing received Heat from KEPCO which is the same as total productive heat. The result has showed that the reduction percentage per day is 2.45~6.80%, and the reduction cost per day is 22,727~60,077 thousand won given the randomly selected sample days. In particular, winter time shows the highest demand with the largest reduction cost whereas summer time illustrates the lowest demand with the smallest reduction cost. Given this result, reduction cost per year compared to actual heat production cost for one year theoretically would be 84 hundred million won. Also, the economic effect showed that the reduction cost percentage per year is more than 2.74% on heat production cost per year for all capital branch offices.

Separation of Lysozyme from Chicken Egg White by Ultrafiltration (1) - Dead-end Filtration of Egg White Solution - (한외여과에 의한 계란 난백으로부터 라이소자임의 분리 (1) - 난백용액의 전량여과 -)

  • Park, Hye-Ri;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.26 no.4
    • /
    • pp.266-272
    • /
    • 2016
  • The separation and purification of lysozyme enzyme from chicken egg white (CEW) solution was studied using the dead-end filtration. The optimum operation conditions of the dead-end filtration reveal that the maximum value of permselectivity of lysozyme to the other proteins of ovalbumin and conalbumin in the CEW solution was tested with change of molecular weight cut-off (MWCO) of ultrafitration membrane and pH of the CEW solution. The optimum operation conditions for the efficient permeable separation of lysozyme from the CEW solution are that the membrane MWCO is 30 kD and the pH of CEW solution is 11. At this optimum operation conditions, the maximum value of permselectivity of lysozyme to total proteins in CEW solution is about 83.