• Title/Summary/Keyword: optimal wavelength

Search Result 269, Processing Time 0.026 seconds

A study on the airborne concentration of welding fume for some manufacturing industries (일부 업종의 용접흄 분석 및 폭로농도에 관한 연구)

  • Byeon, Sang-Hoon;Park, Seung-Hyun;Kim, Chang-Il;Park, In-Jeong;Yang, Jeong-Sun;Oh, Se-Min;Moon, Young-Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.172-183
    • /
    • 1995
  • The airborne concentrations of the welding fumes produced during $CO_2$ arcwelding process at shipbuilding, shiprepairing, container manufacturing and car accessary manufacturing industry were investigated. The effects how much reduced the welding fume were checked when the portable fan was used. The results were as follows; 1.The geometric mean of welding fume concentration in shipbuilding factory was $10.05mg/m^3$. This exposure concentration was higher than other 3 manufacturing industries at 95% confidence level. 2. The sampling filters for welding fume could be digested with acid within 1 hour by microwave oven. The recoveries for investigated metal elements were all over 95%. 3. The optimal wavelength could be selected for the simultaneous analysis of 8 metal elements by ICP(Inductively Coupled Plasma). 4. Noxious gases($O_1,NO_2$) produced during $CO_1$ gas arc welding process were detected that the concentration of ozone($O_1$) was less than 0.01 ppm and that of nitrogen dioxide($NO_2$) was 0.01-0.03 ppm. 5. The geometric mean of welding fume particle diameter was $1.26{\mu}m$ and geometric standard deviation was 1.51 for the counts when particle an analyzer(ELZONE) had been used. 6. When the portable fan had been used,the reduced percent of total welding fume for workers was about 47.8% when portable fan was applied to blow and 71.7% when to exhaust.

  • PDF

The Comparison of Morphological and Constituents of the Leaves of Magnolia officinalis, M. biloba and M. obovata (중국 및 일본산 후박 잎의 형태 및 성분 비교)

  • Park, Seo-Hee;Yun, Ui-Jung;Shin, Jong-Hun;Kwon, Byoung-Mok;Bae, Ki-Hwan
    • Korean Journal of Pharmacognosy
    • /
    • v.37 no.4 s.147
    • /
    • pp.278-282
    • /
    • 2006
  • In this study, we analyzed and quantified the contents of magnolol (1), honokiol (2), and obovatol (3) in the leaves of Magnolia species by HPLC. HPLC methods were developed and validated by ICH guide lines comparing the linearity, intraday precision, inter-day precision. The optimal conditions were as follows; wavelength: 288 nm, column: Zorbax Eclipse XDBC18 $(2.1\times150\;mm,\;5{\mu}m)$, mobile phase: Acetonitril - 0.1 % $H_3PO_4$ (45:55, v/v) buffer, flow rate: 0.5 ml/min. The contents of magnolol, honokiol and obovatol were 1.08%, 2.37%, and 0.57% in the leaves of M. officinalis, 0.50%, 0.03%, and 1.54% in the leaves of M. biloba, 0.37%, 0.03%, and 0.76% in the leaves of M. obovata. The contents of effective ingredients in the leaves of M. officinalis and M biloba were higher than that of M. obovata. Especially, the content of obovatol in the leaves of M. biloba was remarkably high. This result showed that the shapes of leaves have a certain relationship with the content of obovatol.

Anti-inflammatory Activities of Lupane-triterpenoids In Vitro and Their Phytochemical Fingerprinting from Leaves of Acanthopanax gracilistylus

  • Li, Xiao Jun;Dai, Ling;Li, Zhi;Zhang, Xiao Dan;Liu, Xiang Qian;Zou, Qin Peng;Xie, Xia
    • Natural Product Sciences
    • /
    • v.21 no.2
    • /
    • pp.104-110
    • /
    • 2015
  • The activities on the inhibition of NO on LPS-induced RAW 264.7 macrophages were investigated in this work. A simple and sensitive method has been developed and validated for fingerprinting analysis of leaves of Acanthopanax gracilistylus W.W. Smith (AGS). The cytotoxicity and inhibition of NO on LPS-induced RAW 264.7 cells of the extract and triterpenoids were determined. Optimal conditions of HPLC analysis were established as follows. The separation was performed with an ODS-C18 column at $30^{\circ}C$, the detected wavelength was 210 nm, the flow rate was 1 mL/min, and the mobile phase consisted of acetonitrile (0.05% phosphoric acid)-0.05% phosphoric acid solution with gradient elution. Our results showed that impressic acid and acankoreaogenin was more effective on the inhibition of NO than the methanol extract and other compounds. There were seventeen peaks coexisted with similarities above 0.95 and nine lupane-triterpenoids including acankoreaogenin and impressic acid detected and identified. The result of anti-inflammatory activities provides a potential explanation for the use of AGS leaves as a herbal medicine in the treatment of inflammatory diseases. Our results also show that acankoreanogenin and impressic acid may be potentially useful in developing new anti-inflammatory agents. In addition, the fingerprint chromatography clearly illustrated and confirmed the material basis for the anti-inflammatory activities of this plant.

A Study on Design and Fabricate of a Intermediate Frequency Band SAW Filter (IF 대역 SAW 필터 설계 및 제작)

  • 유일현;권희두;정양희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • We have studied a method to design and fabricate the Intermediate Frequency(IF) band pass filter with low shape factor which is used for CDMA base station on the 35°Y-cut X-propagation Quartz substrate. In order to fabricate a device of the low shape factor for the IF SAW filter on this substrate, we employed apodization weighted type interdigital transducer(IDT) as an input and withdrawal weighted type IDT as an output by using impulse modelling method. Also, using the Kaiser-Bessel window function, we have adopted 2200pairs and 1000pairs of input and oueut IDT respectively to minimize the effect of ripple. Furthermore, the width and the space of IDT finger are 3.6 ㎛ and 3.5 ㎛ respectively. Thus, we can have optimal results when the IDT thickness is 6000Å in consideration of the ratio of SAW's wavelength while it's aperture is 2mm for impedance matching. The fabricated SAW filter for CDMA had the property of almost 115.2MHz of a center frequency, less then 1.27MHz of bandwidth, less than 1.3 of shape factor, - l5dB of out band attenuation insertion loss and -45dB of rejection band.

  • PDF

Development of a Flatbed Scanner for Reflection Infrared Photography (반사 적외선 사진을 위한 평판 스캐너의 개발)

  • Choi, Young-Ho;Hwang, Min-Ku;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.57-66
    • /
    • 2011
  • At this time, digital cameras are used in art and forensic science. However, the digital camera has some limitations which need to understand of photograph and lighting. It is a useful paper to make an infrared flatbed scanner. The following processes offer an infrared flatbed scanner development. First, the infrared flatbed scanner changes visible fluorescent lamp to infrared LED. Second, it equips a long-pass filter, which is available to pass over 810nm wavelength, on the glass to complete the optimal infrared flatbed scanner. In addition, it must copy from digital camera to computer directly. The infrared digital camera has disadvantage to always irradiate infrared lamp. Because of difference between visible length and infrared length characteristic, they have different focal distance. This devised scanner for solving mentioned problems does not need to irradiate infrared lamp, and there is not a problem about focal point because the depth of field of flatbed scanner is minimum 2mm. Lastly, the infrared flatbed scanner can make high resolution which is 12,800dpi unlike digital camera. Accordingly, the infrared scanner looks forward to be used in many field of study.

Comparative Analyses of Bioactive Constituents from Forsythia suspensa and Forsythia viridissima by HPLC-DAD

  • Won, Tae-Hyung;Liao, Lijuan;Lee, Seung-Ho;Son, Jong-Keun;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.328-336
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) method was established for the discrimination of a folk medicine Forsythia suspensa and Forsythia viridissima. Five and three representative metabolites of the lignan and phenolic glycoside classes were selected for the analysis from F. suspensa and F. viridissima, respectively. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, $4.6{\times}250$ mm) with the column temperature at $40^{\circ}C$. The mobile phase was composed of methanol and 0.3% acetic acid using an isocratic elution with the flow rate 1 mL/min. Detection wavelength was set at 280 nm. All calibration curves showed good linear regression ($r^2$ > 0.996) within test ranges. Limits of detection (LOD) and limits of quantitation (LOQ) values were lower than 0.096 and 0.291 ${\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.07-0.63% and 0.14-0.62%, respectively, and the overall recoveries of 97.79-102.46% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytical method. The verified method was successfully applied to the quantitative determination of representative metabolites in fifty-three commercial F. suspensa samples and fifteen commercial F. viridissima samples from diverse sources. The overall analytical results showed the unequivocal differences in bioactive constituents between F. suspensa and F. viridissima.

Detection of fluorescence from soils contaminated with monoaromatic hydrocarbons (유류 오염 토양에서의 단일방향족 탄화수소 농도 측정을 위한 자외선 형광 분석에 관한 연구)

  • 김우진;박재우;이주인
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.35-44
    • /
    • 2002
  • In order to determine the contamination of the aromatic hydrocarbons in soil, a fiber-optic sensing technique with fluorescence detector has been proposed. Previous researches have shown that the optimal condition for detecting benzene, toluene, ethylbenzene, xylene (BTEX) was 260 nm /290 nm (excitation/emission wavelength). However, broader fluorescence spectra of BTEX-polluted soil sample ranging from 300 nm to 600 nm were observed. Additionally, the intensity of fluorescence increased with increasing BTEX concentration, which was conspicuous in the fine-particle soil, The overall results indicated that the suggested technique could be useful for in-situ monitoring system for subsurface oil-storage tank.

Growth and Characterization of $CuInTe_2$ Single Crystal thin Films by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE) 방법에 의한 $CuInTe_2$ 단결정 박막 성장과 특성에 관한 연구)

  • 홍광준;이관교;이상열;유상하;정준우;정경아;백형원;방진주;신영진
    • Korean Journal of Crystallography
    • /
    • v.11 no.4
    • /
    • pp.212-223
    • /
    • 2000
  • A stochiometric mix of CuInTe₂ polycrystal was prepared in a honizonatal furnace. To obtain the single crystal thin films, CuInTe₂ mixed crystal was deposited on throughly etched GaAs(100) by the HWE system. The source and substrate temperatures were 610℃ and 450℃ respectively, and the thickness of the deposited single crystal thin film was 2.4㎛. CuInTe₂ single crystal thin film was proved to be the optimal growth condition when the excition emission spectrum was the strongest at 1085.3 nm(1.1424 eV) of photoluminescence spectrum at 10 K, and also FWHM of Double Crystal X-ray Rocking Curve (DCRC) was the smallest, 129 arcsec. The Hall effect on this sample was measured by the method of Van der Pauw, and the carrier density and mobility dependent on temperature were 9.57x10/sup 22/ electron/㎥, 1.31x10/sup -2/㎡/V·s at 293 K, respectively. The ΔCr(Crystal field splitting) and the ΔSo (spin orbit coupling splitting( measured at f10K from the photocurrent peaks in the short wavelength of the CuInTe₂ single crystal thin film were about 0.1200 eV, 0.2833 eV respectively. From the PL spectra of CuInTe₂ single crystal thin film at 10 K, the free exciton (E/sub x/) was determined to be 1064.5 nm(1.1647 eV) and the donor-bound exciton(D/sup 0/, X) and acceptor-bound exciton (A/sup 0/, X) were determined to be 1085.3 nm(1.1424 eV) and 1096.8 nm(1.1304 eV0 respectively. And also, the donor-acciptor pair (DAP)P/sub 0/, DAP-replica P₁, DAP-replica P₂ and self-activated (SA) were determined to be 1131 nm (1.0962 eV), 1164 nm(1.0651 eV), 1191.1 nm(1.0340 eV) and 1618.1 nm (0.7662 eV), respectively.

  • PDF

Optical information storage using diffraction properties of volume hologram in Fe-LiNbO$_3$ crystal (Fe-LiNbO$_3$결정에서 부피형 홀로그램의 회절특성을 이용한 광정보 저장)

  • An, Jun-Won;Kim, Nam;Lee, Kwon-Yeon
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.63-71
    • /
    • 1998
  • In this paper, we experiment the characteristics of coupling coefficient, gain, diffraction efficiency and dependence of time determined by TWM(Two-Wave Mixing), using Fe-LiNbO$_3$ crystal(doped with 0.015Wt.%). From these results, we proposed to apply for optical memory application. The highest coupling angle of 14。 and maximum coupling coefficient of 6.9$cm^{-1}$ / are obtained at 514.5nm wavelength. Also, maximum diffraction efficiency is 54.13% when intensity ratio and writing beam incident angle are 0.1 and 14o, respectively. After fixing process, diffraction efficiency is 21.4%. As an example, we demonstrated the writing and reconstruct optical data using spatial light modualtor and angular multiplexing in most optimal condition.

  • PDF

Determination of Lead in Urine by Atomic Absorption Spectrophotometry (원자흡광법을 이용한 요중 연 배설량의 정량)

  • Paik, Nam-Won;Yoon, Bock-Sang;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.377-381
    • /
    • 1974
  • Determination of lead in urine is important in industrial hygiene and toxicology. Dithizone method has been principally used for the determination of lead in urine, which gives accurate results in skilful hands but is usually complex and time-consuming. Atomic absorption spectrophotometry is a new simple method and several procedures have been described. However, the influences of pH and the presence of chelating agents during treatment of lead poisoning are not clear. The purpose of this study was to find out the effect of pH and chelating agents on the determination of lead using Shimadzu atomic absorption/flame spectrophotometer, model AA-610. The results obtained were as follows: 1. The atomic absorption spectrophotometry(AAS) could be applied without prior acid digestion to specimens in the absence of chelating agents. The absorbance at $2,170\;{\AA}$, though more sensitive, was more noisy electronically. Therefore, we selected the wavelength of $2,833\;{\AA}$ plus scale expansion. 2. The optimal pH was in the range from 2 to 3. 3. The sensitivity was $0.075{\mu}g/ml/%$ and detection limit was about $0.2{\mu}g/ml$. 4. In the presence of EDTA, lead could not be completely determined without prior acid digestion. 5. On specimens from patients receiving penicillamine therapy, a comparison was made between the values obtained with dithizone method and AAS method with prior acid digestion. The results of comparison showed a very good agreement.

  • PDF