• 제목/요약/키워드: optimal operating frequency

검색결과 149건 처리시간 0.03초

Application of the Correlation Technique to Electromagnetic Ultrasonic Nondestructive Evaluation: Theoretical Study and Computer Simulation

  • Zhao, Xin;Wang, Jin-Peng;Tao, Xue-Heng
    • 한국멀티미디어학회논문지
    • /
    • 제9권12호
    • /
    • pp.1628-1635
    • /
    • 2006
  • A new frequency-modulated m-sequence correlation technique was described. It has. been seen that the frequency modulation scheme leads to higher signal-to-noise ratio than direct sequencing and less hardware effort than PSK modulation scheme. The operating frequency of the correlation system was deduced. The optimal frequency for the frequency-modulated m-sequence correlation system should be 1.35 times of the center frequency of the transducer. The application of this correlation technique to electromagnetic ultrasonic system was computer-simulated.

  • PDF

파이프라인형 CORDIC를 이용한 직접 디지털 주파수 합성기 설계 (A Design of a Diredt Digital Frequency Syntheszer with an Array Type CORDIC Pipeline)

  • 남현숙;김대용;유영갑
    • 전자공학회논문지D
    • /
    • 제36D권5호
    • /
    • pp.36-43
    • /
    • 1999
  • 새로운 방식의 직접 디지털 주파수 합성기(Direct Digital Frequency Synthesizer, DDFS)의 설계방식을 제시하였다. 배열형 CORDIC(Coordinate Rotate Digital Computer)을 해석함에 있어서 오차의 크기를 계산하였다. 오차에는 계산회수의 부족에서 발생하는 ‘반복회수오차’와 제한된 데이터 비트수를 사용함으로써 계산에 사용하지 못하는 유효숫자 이하를 버림으로써 발생하는‘절단오차’로 분류할 수 있다. 실제로 각 비트별로 오차를 측정해 보면 8비트시 7단, 16비트시 12단, 24비트시 20단으로 근최적화된 파이프라인 단수를 얻을 수 있었다. 이 DDFS는 FPGA칩으로 구현되었고, 측정결과 235MHz의 구동 클럭에서 안정된 동작을 보였으며, 11.75MHz의 최대 출력 주파수를 발생시켰다. 위상별 진폭값을 ROM에 저장하는 기존의 방식에 비하여, 보다 높은 정밀도와 처리속도를 보이며, 제조공정 역시 단순해 질 것이다. 특히 같은 비트를 채택한 경우 롬방식에 비하여 5배정도의 높은 정밀도를 얻었다.

  • PDF

High-Frequency GaN HEMTs Based Point-of-Load Synchronous Buck Converter with Zero-Voltage Switching

  • Lee, Woongkul;Han, Di;Morris, Casey T.;Sarlioglu, Bulent
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.601-609
    • /
    • 2017
  • Gallium nitride (GaN) power switching devices are promising candidates for high switching frequency and high efficiency power conversion due to their fast switching, low on-state resistance, and high-temperature operation capability. In order to facilitate the use of these new devices better, it is required to investigate the device characteristics and performance in detail preferably by comparing with various conventional silicon (Si) devices. This paper presents a comprehensive study of GaN high electron mobility transistor (HEMT) based non-isolated point-of-load (POL) synchronous buck converter operating at 2.7 MHz with a high step-down ratio (24 V to 3.3 V). The characteristics and performance of GaN HEMT and three different Si devices are analytically investigated and the optimal operating point for GaN HEMT is discussed. Zero-voltage switching (ZVS) is implemented to minimize switching loss in high switching frequency operation. The prototype circuit and experimental data support the validity of analytical and simulation results.

VSI-IM 구동시스템의 고동작 및 고주파영향 최소화를 위한 MM PWM 방식 (MM PWM Scheme for High Performance and Harmonic Effects Minimization of VSI-IM Drive System)

  • Min Soo Kim
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.42-48
    • /
    • 1988
  • MM(multimode) PWM(pulse width modulation) Suitable for high performance and harmonic effects minimization of VSI (voltabge source invertetr)-IM (induction motor)drive system is proposed. The approximated optimal, suboptimal and optimal PWM are implemented in the low frequency range, while square wave operation is realized in the hibh frequency range. The pulse width Modulator is capable of generating control signals to a transistorized inverter operating at about 1KHz. All functions except digital comparison have been implemented in softyware making the scheme economical, flexible and reliable. Pulse width modulator is built and tested experimentally. In order to confirm the effectiveness and the reliability of the theoretical proposition, this scheme is applied to 1Hp, Three phase IM. As results, it is concluded that the scheme of MM PWM is superior to other conventional switching scheme through the discussions or analysis carried out on the items such as line-to-line voltage, current and spectrum of current harmonic components observed at the output terminal of inverter, noise level of motor.

  • PDF

슬라이딩 모우드 제어에 기초한 유연한 2링크 조작기의 진동제어 (Vibration Control of a Flexible Two-link Manipulator based on the Sliding Mode Control)

  • 채승훈;양현석;박영필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.511-516
    • /
    • 2000
  • In order to not only perform as a extreme model under the severe operating condition but also acquire more diverse and advanced control capability utilizing high compliance, active vibration control of a flexible 2-link robot manipulator are investigated. Multi variable-structured frequency shaped optimal sliding mode is proposed for the flexible robot manipulator like control system, whose control variables, an angular motion of joint and vibration of flexible link, have to be controlled simultaneously by one control torque at a driving joint. The control system is divided into two subsystems, a control input related subsystem and an added subsystem. The proposed sliding mode, composed of multi control variables, makes optimized relation between subsystems and a individual control input, thus, the sliding mode controller can compensate whole dynamics of each subsystems simultaneously. And the possibility and effectiveness are verified by vibration control of a manipulator having two flexible links. Simulation and experiment results show that the proposed control scheme achieves the purpose effectively.

  • PDF

회전축 정렬불량 광디스크 드라이브의 진동 저감에 관한 연구 (A Study on Vibration Reduction of an Optical Disk Drive with the Misaligned Axis of Rotation)

  • 강봉진;정태은;신효철;오주환
    • 한국정밀공학회지
    • /
    • 제21권5호
    • /
    • pp.122-130
    • /
    • 2004
  • In a high-speed and wide operating field optical disk drive, the vibration problem is one of the most important factors to be considered for reliable performance. And a disk misaligned with axis of rotation is a major source of vibration in optical disk drive. Furthermore, this vibration disturbance of the disk spindle system causes failure in the reading and writing process. So to solve this vibration problem, the vibration absorber using rubber mount has been introduced in recent years. In this paper, we have analyzed the simple optical disk drive model with dynamic vibration absorber through dynamic analysis of 12-dof by Recurdyn program and obtained optimal mass and frequency ratios of dynamic vibration absorber of dynamic vibration absorber and the optimal frequency ratio.

심해용 무인잠수정 구조의 민감도해석에 의한 최적설계 (Optimal Design of the Deep-sea Unmanned Vehicle Frame Design Sensitivity)

  • 이재환;허유정;정태환;이종무
    • 대한조선학회논문집
    • /
    • 제41권3호
    • /
    • pp.28-34
    • /
    • 2004
  • This paper presents the results of the structural analysis and optimal design of the ROV to be operated at 6000m depth in the ocean. This will be the first domestic deep-sea ROV operating with an AUV and a launcher equipped with robot arms and the current weight is about 3 ton. initial optimal dimension of the frame is determined based on the stress analysis using FEA code ANSYS and design sensitivity and optimization results. The current design is the initial design and there is a possibility to change the design according to the modification of material, equipments and array of structure.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

주파수가 선형적으로 변하는 조화 입력에 대한 복소 최소자승오차법의 추종 특성 (Tracking characteristics of the complex-LMS algorithm for a sweeping frequency sine-wave signal)

  • 배상준;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.173-176
    • /
    • 1996
  • The transient behavior of the complex-LMS adaptive filter is studied when the adaptive filter is operating on a fixed or sweeping complex frequency sine-wave signal. The first-order difference equation is derived for the mean weights and its closed form solution is obtained. The transient response is represented as a function of the eigenvectors and eigenvalues of input correlation matrix. The mean-square error of the algorithm is evaluated as well. An optimal convergence parameter and filter length can be determined for sweeping frequency sine-wave signals as a function of frequency change rate and signal and noise powers.

  • PDF

5kW급 플라즈마 방전장치 설계 최적화의 관한 연구 (A Study on the Optimal Design of 5 kW Plasma Discharger)

  • 노현규;신철준;이준영
    • 전력전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.150-159
    • /
    • 2016
  • This paper presents a study on the design optimization of a 5 kW plasma discharger for driving plasma reactor. The proposed study is composed of a high-frequency inverter based on the full-bridge circuit using soft switching techniques for high-frequency switching. The switching frequency in the operating region is the area of 130-200 kHz. By applying the LC resonance technique and a variable switching frequency, control technique is designed to be stable under changes in the load characteristics of the plasma reactor. This paper presents a quantitative analysis technique for design optimization. Experiments are performed according to load characteristic variations depending on the vacuum of the plasma reactor. This paper has verified the topology and design method for the 5 kW plasma discharger design.