• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.028 seconds

Correlation between Visual Symptoms and the Academic Performance as Assessed by COVD-QOL Questionnaire in Primary School Children (COVD-QOL을 사용하여 평가한 눈이상이 초등학교 어린이의 학업수행능력에 미치는 영향)

  • Shin, Hoy-Sun;Park, Sang-Chul;Park, Chun-Man
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.9 no.2
    • /
    • pp.81-90
    • /
    • 2008
  • Objectives: Since 80% of the information we get from the environment comes in through our eyes (Anshel JR, 1999), uncorrected visual problems negatively affect children's educational process and perceptual development. The objectives of this study were: 1st, to document the prevalence of learning related vision problem in primary school children. 2nd, to compare responses of children with those of parents on visual symptoms. Lastly, to determine if there is an association between visual symptoms and academic performance. Methods: We administered visual-symptom quality of life questionnaire developed by Oklahoma College of Optometry in Vision Development to 1031 primary school children and their parent. Visual symptoms responded by children and their parents were compared using Independent Sample t-test and the relation between visual symptoms and academic performance were calculated using Pearson Correlation tests. Results and Conclusions: The number of children who need further professional evaluation, that is visual-symptom scores were ${\geq}20$, reported by children(25%) was greater than that reported by parents(16%). And visual-symptom scores reported by children were significantly higher than those reported by parents in every grade(p<0.01, p<0.001). Visual symptoms reported by both children and parents were found to be inversely correlated to academic performance in every academic area and most of their correlations were statistically significant(p<0.05). Therefore, children with more visual-symptom reported by both group had negative effects on children's academic performance.

  • PDF

A Study on Health Effects of VDT Syndrome in Hospital Workers (병원종사자의 VDT증후군 자각증상과 건강영향에 관한 연구)

  • Lee, SeungHwan;Jeong, Byeong Gon;Lee, Gyu Chan;Lee, Gwang Cheol;Bae, Seong Bock
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.87-98
    • /
    • 2012
  • Purpose : This study aims to examine hospital employees' subjective symptoms of VDT syndrome (Video display terminal syndrome) and figure out their effects on health conditions and correlations. Materials and Methods : This study used a structured self-administering questionnaire and gained data from 125 subjects. The questionnaire consists of total 62 questions, and they went through real number, percentage, ${\chi}^2$-terst, t-test, one-way ANOVA, and logistic regression analysis. Results : Regarding the difference in the types of subjective symptoms of VDT syndrome by jobs, there was statistically significant difference in ophthalmic symptoms, systemic symptoms, and musculoskeletal symptoms. About the correlation between the subjective symptom points of VDT syndrome by the types of symptoms, there was statistically significant correlation all in skin trouble, backache, upper limb muscle pain, lower limb muscle pain, fatigue in the head and eyes, and depression or anxiety disorders. There was significant correlation between the subjective symptom points of VDT syndrome and subjective health conditions. Conclusion : Hospital employees' subjective health conditions had significant correlation with subjective symptom points of VDT syndrome. This result shows that as radiologists' and also other hospital employees' working conditions change into VDT environment, VDT syndrome gradually appears more and more. This implies that it is needed to designate not only radiologists but also all the other hospital employees as jobs exposed to the working environment of VDT syndrome and provide preventive measures, education, and publicity for it afterwards.

  • PDF

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young;Ye, Ki-Hun
    • Journal of Integrative Natural Science
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.

Thermal and Mechanical Properties of EPDM and CR Compounds with Various Fillers and Its Contents for V-rib Belt (V-rib 벨트용 EPDM과 CR의 고온 내구성과 기계적 물성에 미치는 충전제의 영향)

  • Seo, Kwan-Ho;Hwang, Byung-Kook;Hong, Ki-Heon;Park, Hae-Youn;Jeon, Il-Ryeon
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.299-307
    • /
    • 2009
  • The effects of reinforcing materials on durability and mechanical properties of V-rib belt were investigated. Cotton fiber and ZnO were used as a filler for CR, and cotton and aramid fiber were used for EPDM rubber compounds. These materials were prepared as a specimen and V-rib belt for heat resistant and mechanical test. High contents of ZnO give improved wear resistance, and higher contents of cotton fiber showed higher durability in high rotation speed but lower wear resistance for CR rubber compounds. Using the aramid and cotton fiber together in EPDM rubber compounds, thermal and wear resistance were improved simultaneously. The material containing EPDM matrix showed better durability and wear resistance than those of containing CR matrix comparing in the same cotton fiber contents.

The influence that the medical service quality of the dental clinic affects to the patient satisfaction and use intention (치과 병·의원의 의료서비스 품질이 환자만족도와 재이용 의도에 미치는 영향)

  • Jeong, In-Ho;Lee, Sook-Jeong;Kim, Byung-Sik;Park, Young-Dae;Ji, Kyung-Ja;Park, Ji-Young;Hwang, Hye-Kyung;Lee, Jong-Hwa
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.387-394
    • /
    • 2013
  • Purpose: This aim of this paper is to research the influence of customer satisfaction and reutilization on Dental hospitals and clinics of medical service quality. Methods: The study examines 140 Patients who received treatment in Daegu from 1 July 2012 to 30 July 2012. The methods of research were used to factor analysis, reliability test using Cronbach's ${\alpha}$ factor, correlation analysis, multiple regression analysis and spss/win18.0. Results: The factor of quality of care has the highest impact on customer satisfaction. the influence of reutilization depends on the highest reliability and the physical environment was significant. Conclusion: To improve customer satisfaction and reutilization is required to maintenance of hospital facilities, medical services mind and quality of care. The medical service providers are important to develop patient education programs, self-development and customer satisfaction training techniques.

A Case of Choroidal Melanocytoma with Optic Nerve Involvement in a Dog

  • Jinseon Chang;Dajeong Jeong;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Clinics
    • /
    • v.40 no.4
    • /
    • pp.283-287
    • /
    • 2023
  • A 10-year-old spayed female beagle dog presented with a 2-month history of third-eyelid elevation in the left eye (OS). Ophthalmic examination revealed slightly diminished corneal and palpebral reflexes along with exophthalmos in the OS. Schirmer's tear test and intraocular pressure values were within the normal range for the OS. Slit-lamp biomicroscopy revealed protrusion of the third eyelid and corneal opacity in the OS. Fundoscopy revealed a prominent black mass in the OS covering the optic nerve. Tapetal hyper-reflectivity was also observed around the mass. Ocular ultrasonography showed a 0.74 × 0.67 cm echogenic posterior segment mass around the optic nerve protruding into the retrobulbar space. Computed tomography revealed a contrast-enhanced soft tissue lesion in the posteromedial aspect of the left eyeball protruding into the retrobulbar region, and the optic nerve was suspected to be involved. No evidence of osteolytic changes in the adjacent bone or distant metastasis was observed. Enucleation was performed to prevent potential metastasis or local invasion of the mass and to relieve discomfort due to exposure to keratopathy resulting from lagophthalmos. Histopathological examination revealed a central choroidal melanocytoma extending into the optic nerve. No local recurrence was detected until 16 months postoperatively.

Aided Distance Visual Acuity and Refractive Error Changes by Using Smartphone (스마트폰 사용이 원거리 교정시력과 굴절 이상 변화에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Young Gul;Kim, Da Yeong;Park, Jin Young;Sin, Won Chul;Yoon, Jeong Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.305-309
    • /
    • 2012
  • Purpose:This study was conducted to research any effect on aided distance visual acuity and refractive error changes by using smartphone at near for long term. Methods: 20($20.6{\pm}0.9$ years) young adults subjects with no ocular diseases, over 0.8 of aided distance visual acuity, normal amplitude of accommodation and normal accommodative facility agreed to participate in this study. The subjects were divided into two group, Group 1 (15 cm fixation distance) included 10 subjects and Group 2(40 cm fixation distance) included 10 subjects. Aided distance visual acuity and refractive error were measured before and after using smartphone for 30 minutes by auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea), auto refractor-keratometer (MRK-3100, Huvitz, Korea). After then, the subjects looked at distance with wearing spectacles. Refractive error was measured at 5 minutes, 10 minutes, and 15 minutes later, respectively. Results: After using smartphone at 15 cm for 30 minutes, there was statistically significant reduction of aided distance visual acuity (p=0.030) and increasing myopia (p=0.001). The increased myopia was not statistically significant after 5 minutes rest (p${\geq}$0.464). However there was no statistically significant changes in aided distance visual acuity (p=0.163) and refractive error (p=0.077) after using smartphone at 40 cm for 30 minutes. Conclusions: It is recommend to keep 40 cm off the smartphone from eyes to avoid any aided distance visual acuity and refractive error changes. If smartphone is used closer than 40 cm, a rest for 5 minutes is also recommend after every 30 minutes use with smartphone to avoid any aided distance visual acuity and refractive error changes.

The Effects of the Relative Legibility of Optotypes on Corrected Visual Acuity (시표의 유형에 따른 상대가독성이 교정시력에 미치는 영향)

  • Ha, Na-Ri;Choi, Jang-Ho;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.177-186
    • /
    • 2015
  • Purpose: The Purpose of this study is to investigate if the relative legibility of optotypes affects the corrected visual acuity in visual acuity test. Methods: After measuring the relative legibility of 'Landolt ring target', 'arabic number target', 'alphabet target' by showing as a single-letter-target in 24 subjects without specific ocular diseases and ocular surgery experience, the relative legibility of 0.8, 1.0, 1.25 row of vision according to type of target in 7 types of chart were compared. After then we compared by measuring the corrected visual acuity according to type of target by using binocular MPMVA test (#7A) in 60 myopic subjects. Results: In 3 types of target the worst relative legibility target was 'Landolt ring target' with legible distance of $98.97{\pm}4.57cm$ and the best relative legibility target was 'alphabet target' with legible distance of $108.42{\pm}3.46cm$. There was no difference of the relative legibility according to type of chart or visual acuity level in the row of vision if other conditions are the same. In 1.0 and 1.25 row of vision the difference of relative legibility according to type of target was shown the statistically significant difference between 'Landolt ring target' and 'alphabet target' as $-0.07{\pm}0.06$ (p=0.02) and $-0.06{\pm}0.06$ (p=0.04) respectively. In myopia the difference of corrected visual acuity according to type of target was statistically significant difference between 'Landolt ring target' and 'arabic number target' as $-0.04{\pm}0.02$ (p=0.02) and it was especially remarkable in the low myopia. Conclusions: Measuring visual acuity with different optotypes could cause the errors in best vision measurement value because there was difference of the relative legibility according to type of target even though visual acuity level is same in the row of vision.

Evaluation of General Toxicity and Genotoxicity of the Silkworm Extract Powder

  • Heo, Hyun-Suk;Choi, Jae-Hun;Oh, Jung-Ja;Lee, Woo-Joo;Kim, Seong-Sook;Lee, Do-Hoon;Lee, Hyun-Kul;Song, Si-Whan;Kim, Kap-Ho;Choi, Yang-Kyu;Ryu, Kang-Sun;Kang, Boo-Hyon
    • Toxicological Research
    • /
    • v.29 no.4
    • /
    • pp.263-278
    • /
    • 2013
  • The silkworm extract powder contain 1-deoxynojirimycin (DNJ), a potent ${\alpha}$-glycosidase inhibitor, has therapeutic potency against diabetes mellitus. Therefore, natural products containing DNJ from mulberry leaves and silkworm are consumed as health functional food. The present study was performed to evaluate the safety of the silkworm extract powder, a health food which containing the DNJ. The repeated toxicity studies and gentic toxicity studies of the silkworm extract powder were performed to obtain the data for new functional food approval in MFDS. The safety was evaluated by a single-dose oral toxicity study and a 90 day repeated-dose oral toxicity study in Sprague-Dawley rats. The silkworm extract powder was also evaluated for its mutagenic potential in a battery of genetic toxicity test: in vitro bacterial reverse mutation assay, in vitro chromosomal aberration test, and in vivo mouse bone marrow micronucleus assay. The results of the genetic toxicology assays were negative in all of the assays. The approximate lethal dose in single oral dose toxicity study was considered to be higher than 5000 mg/kg in rats. In the 90 day study, the dose levels were wet at 0, 500, 1000, 2000 mg/kg/day, and 10 animals/sex/dose were treated with oral gavage. The parameters that were monitored were clinical signs, body weights, food and water consumptions, ophthalmic examination, urinalysis, hematology, serum biochemistry, necropsy findings, organ weights, and histopathological examination. No adverse effects were observed after the 90 day administration of the silkworm extract powder. The No-Observed-Adverse-Effect-Level (NOAEL) of silkworm extract powder in the 90 day study was 2000 mg/kg/day in both sexes, and no target organ was identified.

Correlations between Higher-order Aberrations and Myopic Degree (근시도와 고위수차와의 상관관계)

  • Ryu, Nam-Yul;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the correlation between higher-order aberration and myopic degree by the analysis of fluctuation of high-order aberration according to the change of myopic degree in certain ranges of myopia and astigmatism. Methods: The high-order aberration in a total of 992 eyes was analyzed by using a LADARWave device employing Hartmann-Shack system, and the relation between high-order aberration and myopia by the change of myopic degree through manifest refraction test. Results: In all subjects, spherical aberration and total coma aberration were significantly increased by the increase of myopic degree, however, trefoil aberration and astigmatic aberration and tetrafoil aberration were decreased. With the group of lower myopic degree, the change of coma aberration was greater by myopic degree and its change was significantly different. The change of spherical aberration by myopic degree was greatly large in the a group of -3.00 D or more and the group of -6.00 D or more where as its change was not large in the group of lower than -3.00 D. The significant decrease of coma aberration was observed only in the group of astigmatic degree of -1.00 D or less when analyzing the correlation between the higher-order aberrations and myopia in the certain groups of astigmatic degree. In the case of spherical aberration, the significant change was shown in all astigmatic groups, however, its increase was larger with the increase of myopic degree in lower degree of astigmatism. The consistent relationship in variations of horizontal and vertical coma aberration in certain myopic and astigmatic groups was neither established nor statistically significant. Conclusions: It is concluded that the correlation between the higher-order aberration and low-order aberration obtained from the results of the present study can help the understanding related to vision quality and the improvement of vision quality.