DOI QR코드

DOI QR Code

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young (Department of Ophthalmic Optics, Sehan University) ;
  • Ye, Ki-Hun (Department of Visual Optics, Baekseok University)
  • Received : 2013.01.02
  • Accepted : 2013.03.25
  • Published : 2013.03.30

Abstract

Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.

Keywords

References

  1. K. W. Gellatly, N. A. Brennan, and N. Efron, "Visual decrement with deposit accumulation of HEMA contact lenses", Am. J. Optom. Phys. Opt., Vol. 65, pp. 937-941, 1988. https://doi.org/10.1097/00006324-198812000-00003
  2. C. E. Soltys-Robitaille, D. M. AmmonJr.,and P. L. GrobeJr., "The relationship between contact lens surface charge and in-vitro protein deposition levels", Biomaterials, Vol. 22, pp. 3257-3260, 2001. https://doi.org/10.1016/S0142-9612(01)00163-6
  3. M. G. Baines, F. Cai, and H. A. Backman,"Adsorption and removal of protein bound to hydrogel contact lenses", Optom. Vis. Sci., Vol. 67, pp. 807-810, 1990. https://doi.org/10.1097/00006324-199011000-00003
  4. V. Compan, A. Andrio, A. Lopez-Alemany, E. Riande, and M. F. Refojo, "Oxygen permeability of hydrogel contact lenses with organosilicon moieties", Biomaterials, Vol. 23, pp. 2767-2772, 2002. https://doi.org/10.1016/S0142-9612(02)00012-1
  5. B. A. Holden and G. W. Mertz, "Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses", Invest.Ophth. Vis. Sci., Vol. 25, pp. 1161-1167, 1984.
  6. E. B. Papas, C. M. Vajdic, R. Austen, and B. A. Holden, "High-oxygen-transmissibility soft contact lenses do not induce limbalhyperaemia", Curr. Eye Res.,Vol. 16, pp. 942-948, 1997. https://doi.org/10.1076/ceyr.16.9.942.5049
  7. R. M. Hill and I. Fatt, "Oxygen uptake from a reservoir of limited volume by the human cornea in vivo", Science, Vol. 142, pp. 1295-1297, 1963. https://doi.org/10.1126/science.142.3597.1295
  8. T. H. Kim and A. Y. Sung, "Copolymerization and contact lens application of HEMA-substituted polyphosphazene", J. Kor. Chem. Soc., Vol. 53, pp. 340-344, 2009. https://doi.org/10.5012/jkcs.2009.53.3.340
  9. K. H. Ye, S. H. Cho, and A. Y. Sung, "Study on the antibiosis and physical properties of copolymer containing silver", J. Kor. Chem. Soc., Vol. 53, pp. 542-546, 2009. https://doi.org/10.5012/jkcs.2009.53.5.542
  10. T. H. Kim, K. H. Ye, and A. Y. Sung, "A study on the measurement of water content in hydrogel contact lens by gravimetric method", J. Korean Oph. Opt. Soc., Vol. 13, pp. 59-63, 2008.
  11. T. H. Kim, K. H. Ye, Y. S. Kwon, and A. Y. Sung, "Polymerization of contact lens materials using silicone", J. Korean Oph. Opt. Soc., Vol. 11, pp. 143-159, 2006.