• Title/Summary/Keyword: operational test

Search Result 1,003, Processing Time 0.027 seconds

Injection Molded Microcellular Plastic Gear (II) - Characteristics of the Counter Pressurized Microcellular Plastic Gear - (초미세발포 플라스틱 기어에 관한 연구 (II) - 카운터프레셔 초미세발포 플라스틱 기어의 특성 -)

  • Ha Young Wook;Takahashi Hideo;Chong Tae Hyong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.655-662
    • /
    • 2005
  • This paper investigates the improvement of accuracy and fatigue life of the developed counter pressurized microcellular gears of polyacetal. It is shown that the fatigue life and operational characteristics of the counter pressurized microcellular gears are more improved than conventional injection molded plastic gears by the dynamic gear durability test. For the cases of test sea.5. conventional injection molded sea.5(SGea.) and counter pressurized microcellular gears(CGear) are manufactured. Durability test is performed on both conventional lnjection molded gears and counter pressurized microcellular gears. Accuracy variation and operational characteristics on fatigue life, wear and tooth surface temperature of CGear and Scear are compared and represented. Operational characteristics of the proposed counter pressurized microcellular gears show a good result in this research. The durability limit of counter pressurized microcellular gears is also obtained, and represented by a function of unit load as well as by a function off-factor.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.

Synthetic Circuit for Thyristor controlled Reactor of Static Var Compensator operational Test (SVC의 TCR Operational Test를 위한 합성시험회로)

  • Kim, Young Woo;Lee, Jin Hee;Jung, Teag Sun;Baek, Seung Taek;Chung, Young Ho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.51-52
    • /
    • 2014
  • 전력계통은 전력수요의 지속적인 성장에 따라서 전력설비의 추가를 지속적으로 추진하고 있지만, 심해지는 환경문제 등으로 인해 용지 확보에 어려움이 있다. 이로 인해 송전선로 장거리화, 용량부족량 등 전력계통에 여러 가지 복잡한 문제가 야기되는데, 이것은 곧 전력계통의 안정도와 직결된다. 이러한 문제를 효과적이면서 경제적인 해결방법으로 FACT(Flexible AC Transmission System)기술이 주목 받고 있다. FACTS 기기 중 SVC(Static Var Compensator)는 상용운전 중이며, 기존 동기조상기에 비해 저렴하고, 신속 정확한 전압제어를 하는 장점이 있다. SVC는 TCR(Thyristor Controlled Reactor)과 TSC(Thyristor Switched Capacitor), FC(Fixed Capacitor)등 여러 종류의 구성을 가질 수 있다. TCR과 TSC는 실제 운전에 앞서 여러 가지 방법으로 검증이 필요하다. 합성 시험회로 설비(Synthetic Test Circuit)는 TCR과 TSC 안에 존재하는 Thyristor Valve의 동작을 실제 동작 조건으로 동작시켜, 동작의 신뢰성을 검증하는 설비이다. 본 논문에서는 TCR의 Operational Test를 위한 STC를 기술하고 있다. 설계된 STC는 PSCAD를 사용하여 검증하였다.

  • PDF

A Design of Operational Test & Evaluation System for Weapon Systems thru Process-based Modeling (프로세스 기반의 모델링을 통한 무기체계 운용시험평가 시스템 설계)

  • Lee, Beom;Seo, Yoonho
    • Journal of the Korea Society for Simulation
    • /
    • v.23 no.4
    • /
    • pp.211-218
    • /
    • 2014
  • The Test and Evaluation (T&E) system became more important due to its advancement and complexity of the weapon system. Time and cost saving T&E related studies are in progress mainly with advanced countries. By utilizing the Modeling and Simulation (M&S) technology recently, we may save time and money. Also, overcome security and safety limitations. There are many M&S based research activities in South Korea but it is way behind of the system that some countries already have developed. i.e.; United States. This area of study requires new way of developing strategies in the T&E system of Korea. This study is to design the Operational T&E system for weapon systems based on modeling of processes. And we modeled the processes of operational performance evaluation through utilizing resources and performance modules of weapon systems and combined it with the simulation engine for 3D visualization. Through this, we propose the Operational T&E system for weapon systems based on modeling of processes that represent operational performances visually.

High Performance Work System and Operational Performance: Focusing on a Mediating Role of Employee Performance (고성과작업시스템과 운영성과 간 관계: 다수준분석을 통한 종업원성과의 매개역할을 중심으로)

  • Jun, In;Oh, Sun Hui;Ahn, Seong Ik
    • Korean Journal of Labor Studies
    • /
    • v.19 no.1
    • /
    • pp.65-104
    • /
    • 2013
  • This study aims to examine the intermediary roles of employee performance between high performance work system (HPWS) and its operational performance on the resource based view. Taking into account the unit of analysis, this study used a hierarchical linear modeling analysis in order to test rigorously the association between HPWS at the organisational level and employee performance at the individual level. For this empirical test, Human Capital Corporate Panel (HCCP) data including 316 firms and 7,872 respondents (including 923 team leaders) were used. To meet the unit of analysis and test the mediation effect, data at the individual and team level were aggregated into the organisational level. The empirical results show that HPWS have a positive impact on operational performance as well as employee performance such as job satisfaction, organisational commitment and organisational trust. Regarding the mediation effect, job satisfaction and organisational trust mediate between HPWS and operational performance. Theoretical implications are discussed in conclusion.

Mediating Effect of Operational Capabilities on the Dynamic Capabilities and Performance of Korean SMEs (동적역량과 기업성과에 대한 운영역량의 매개효과 분석)

  • Bae, Sun-Cheol;Kim, Byung-Keun
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.41 no.4
    • /
    • pp.15-32
    • /
    • 2016
  • This study examines the relationship between dynamic capabilities and operational capabilities as well as investigates the effect of these capabilities and performance. We also test these relationships on two industry groups categorized into high-tech industries and low-tech industries. We collected 221 firms' data from a questionnaire survey of small and medium-sized enterprises in Korea. Empirical results show that dynamic capabilities and operational capabilities influence performance positively. In high-tech industries dynamic capabilities directly affect performance while marketing capabilities appear to mediate the relationship between dynamic capabilities and performance. Dynamic capabilities show no significant effect on performance for low-tech industries; however, operational capabilities do mediate the relationship between dynamic capabilities and performance.

Corporate Social Responsibility Impact on Business Performance through Green Supply Chain Management: Evidence from Guatemala

  • Garcia, Ruben Avila;Park, Byungjoo;Chang, Byeong-Yun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.59-64
    • /
    • 2019
  • The purpose of this research is to examine the relationship between corporate social responsibility (CSR), green supply chain management (GSCM) practices, and business performances. After reviewing the extensive literature, we developed a research model including five constructs: CSR, GSCM practices, environmental, economic and operational performances. We conducted the statistical analyses based on the primary data collected from a survey questionnaire, responded by 93 different company managers in the Republic of Guatemala. Furthermore, we utilized structural equation modeling to analyze the data and to test the hypotheses. The results of the analyses showed that there is a significant influence of CSR on the adoption of GSCM practices. It was also found that GSCM practices have a significant influence on environmental, economic and operational performances. In addition, environmental performance has a significant impact on economic and operational performance. Finally, GSCM has a mediating role on the relationship between CSR and environmental and economic performance, but not with operational performance.

A Study on the Operational Environment of Signalling System (신호시스템 운용환경에 관한 연구)

  • 정의진;이종우;황종규
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.164-171
    • /
    • 2000
  • To determine operational requirement, the environmental condition for an equipment must be investigated, and to certify equipment's normalized operation, appropriate test must be carried out under the considered environmental condition. The actual environmental conditions to which equipment is likely to be exposed are normally complex and will comprise a number of environmental factors and corresponding parameters, When defining the environmental conditions for a certain application it is, therefore, necessary to list the factors involved and select the appropriate severity. For the preparation to determine operational requirement, environmental condition of equipment is investigated. The environmental condition is structured in two separate such as requirements, guidance and test specifications. For the first step, environmental requirements are considered

  • PDF

An OTA with Positive Feedback Bias Control for Power Adaptation Proportional to Analog Workloads

  • Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.326-333
    • /
    • 2015
  • This paper reports an adaptive positive feedback bias control technique for operational transconductance amplifiers to adjust the bias current based on the output current monitored by a current replica circuit. This technique enables operational transconductance amplifiers to quickly adapt their power consumption to various analog workloads when they are configured with negative feedback. To prove the concept, a test voltage follower is fabricated in $0.5-{\mu}m$ CMOS technology. Measurement result shows that the power consumption of the test voltage follower is approximately linearly proportional to the load capacitance, the signal frequency, and the signal amplitude for sinusoidal inputs as well as square pulses.

Influence of asphalt removal on operational modal analysis of Egebækvej Bridge

  • Umut Yildirim
    • Smart Structures and Systems
    • /
    • v.31 no.2
    • /
    • pp.171-181
    • /
    • 2023
  • Using the most up-to-date system identification methods in both time and frequency domains, the dynamic monitoring data from the reinforced concrete Egebaekvej Bridge near Holte, Denmark, is examined in this investigation. The bridge was erected in the 1960s and was still standing during test campaign before demolishing. The ARTeMIS Modal was adopted to derive the modal parameters from ambient vibration data. Several Operational Modal Analysis (OMA) approaches were applied, including Enhanced Frequency Domain Decomposition (EFDD), Curve-fit Frequency Domain Decomposition (CFDD), and Frequency Domain Decomposition (FDD). Afterward, Principal Component (SSI-PC), Unweighted Principal Component (SSI-UPC) Stochastic Subspace Identification methods were utilized. Danish engineering consulting company, COWI with the allowance of the bridge contractor BARSLUND, allow the researcher for this experimental test to demonstrate the impact of OMA applications.