• Title/Summary/Keyword: operational test

Search Result 1,003, Processing Time 0.028 seconds

A Study on the Case Study and Evaluation Methodology of Operational Availability for a Naval Ship using OT&E Data (운용시험평가 데이터를 활용한 함정 운용가용도 평가 방안 및 사례 연구)

  • Paik, Soonhuem
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.471-478
    • /
    • 2014
  • Navy forces of ROK asked for more than 90% operational availability in the requirement document of combat ship. This study proposes the evaluation methodology of operational availability with the evaluation process, calculation formula, analysis of operational test data. As the case study, the developed methodology is proved to apply for 00 batch-I naval ship using the data to be acquired during the operational test period. The operational availability by test data was 90.03%, and it was satisfied with objective value 90%. The paper will contribute not only to establish the evaluation methodology of operational availability for combat ship but also other general weapon system.

Prediction of Safety Critical Software Operational Reliability from Test Reliability Using Testing Environment Factors

  • Jung, Hoan-Sung;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.49-57
    • /
    • 1999
  • It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately.

  • PDF

A Design of a Simulation Platform to Test PRT Vehicle Operational Control Algorithms Using On-board Embedded Process Board (차상용 임베디드 제어보드를 이용한 PRT 차량 운행제어 알고리즘 시험을 위한 플랫폼 설계)

  • Lee, Jun-Ho;Jeong, Rac-Gyo;Kim, Yong-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1962-1967
    • /
    • 2009
  • This paper deals with a design of a platform to simulate PRT vehicle operational control algorithms using on-board embedded process board. The configuration of the platform is composed of the central control module, the station control module, man-machine interface and monitoring module. Since PRT system needs inherently very reliable vehicle operational control algorithm in order to avoid the impact between vehicles, it is very important to construct a simulation platform to test a designed vehicle operational control algorithm during the development process For the test of the proposed platform a path of the each moving vehicle is predefined in the central control system before the dispatch order is given to the vehicle. The simulation results show the effectiveness of the proposed simulation platform for test and evaluation of the PRT operational control algorithms.

A Study on the Improvement of set-up of Required Operational Capability set up and Test & Evaluation method of Weapon System (무기체계 작전운용성능 설정 및 시험평가방법 개선에 대한 연구)

  • Eom, Dong Hwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.2
    • /
    • pp.9-16
    • /
    • 2019
  • The most important task in acquiring the weapon system is to determine the required performance and to test & evaluate it. The importance of the weapon system by ROC (Required Operational Capability) is not considered, and system development and test evaluation are carried out. In addition, technical incidental performance is tested on the same basis as ROC in the test evaluation and determined according to the result. Development test and evaluation that evaluates technical ability is very important, but development agency is supervised and performed. In this paper, we propose a method to give weights considering the importance of ROC, a technical incidental performance determination and test procedure, and a improvement plan for the development and operational test & evaluation.

A Design of a Simulation Apparatus for the Control of the Personal Rapid Transit(PRT) Vehicles (소형궤도 차량 제어를 위한 모의실험 장치 설계)

  • Lee, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2001-2005
    • /
    • 2008
  • This paper presents a design of a simulation apparatus to evaluate an operational control algorithm for the PRT system. PRT systems require very short headways to increase the line capacity and a very reliable vehicle control algorithm for avoidance of the impact between vehicles. Therefore, it can be said that the development of an reliable operational control algorithm for the PRT systems is much more important than that of the hardware configurations. In this paper an apparatus is proposed which is composed of virtual vehicles, a central control system, a man-machine interface and monitoring device, making it possible for the designed operational control algorithm to be implemented and tested. For the test of the proposed apparatus a test operational control algorithm is designed and the experimental results show the effectiveness of the proposed simulation apparatus for test and evaluation of the PRT operational control algorithms.

High School Students' Preferences of Concrete and Formal Operational Levels of Instructions in CAI (구체적 조작수준과 형식적 조작수준의 CAI 형태에 대한 학생의 선호경향)

  • Kim, Young-Soo
    • Journal of The Korean Association For Science Education
    • /
    • v.6 no.2
    • /
    • pp.9-13
    • /
    • 1986
  • This study was designed to investigate students' preferences of instructional modes in CAI which have concrete of formal operational level instructions. Thirty five students of the high school in America were assessed using Longeot test and were given CAI material on the Apple II e computer. The results of this study showed that students who were only capable of functioning at the concrete level of operations frequently preferred to attempt formal operational level instructions for which they were not capable of success. Further, formal operational students frequently preferred concrete operational instructions. There was also no significant difference in the selection of formal operational level of instructions between concrete and formal operational students. There was also no significant correlation between the number of selected formal operational level instructions and the Longeot test score. These results suggested the student's preference to a cognitive developmental level of instruction in CAI was independent of his or her cognitive developmental level.

  • PDF

Synthetic Test Circuit protection design for HVDC Valve Operational test (HVDC Valve Operational Test를 위한 합성시험설비 보호 설계)

  • Kim, Young Woo;Baek, Seung Taek;Lee, Uk Hwa;Chung, Young Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.516-517
    • /
    • 2013
  • 신재생 에너지의 비중 확대와 보급이 늘어남에 따라, 국가 간, 도시 간의 송전이 중요한 이슈로 대두 되고 있다. 위와 같은 요구 조건을 만족시키기 위해서 초고압 직류 송전의 개발이 필요하다. 초고압 직류송전(HVDC)에는 전류형과 전압형으로 나뉘는데. 각 HVDC에서 사용되는 Valve는 실제 운전 전에 여러 가지 방법으로 검증이 필요하다. 합성 시험회로 설비(Synthetic Test Circuit = 이하 STC)는 전류형 HVDC에서 사용되는 주요 전력변환 장치로, Thyristor Valve의 동작을 실제 동작 조건에 맞추어 동작을 시켜, 동작의 신뢰성을 검증하는 시험 설비이다. 본 논문에서는 전류형 HVDC Valve의 Operational Test를 위한 STC의 보호기능에 대해 기술하고 있다. 합성시험회로는 2상 초퍼와 6 펄스 사이리스터 컨버터를 사용하였고 설계된 보호기능은 PSCAD를 사용하여 검증하였다. HVDC Valve Operational Test시 합성시험회로 내에서 발생할 수 있는 사고 상황을 상정하고 그에 따른 보호 기능을 모의하였다.

  • PDF

Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet (환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Bang, Jae-Gun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor (환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Chun, Tae-Hyun;Kim, Hyung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour (한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구)

  • Park, Jinwon;Park, Youngchan;Kim, Seonjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.