• Title/Summary/Keyword: operational methods

Search Result 1,032, Processing Time 0.034 seconds

Character Analysis that influences to Surgical Gloves Punctures (수술장갑의 천공에 영향을 미치는 특성 분석)

  • Kim, Eu Jin;Koh, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.99-110
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the puncture incidence of surgical gloves in an operational setting. Methods: The 277 surgical gloves were used collecting at one general hospital located in Seoul from February 1, 2011 to April 3. The data were analyzed by $x^2$ test, Fisher's exact test, and multiple logistic regression. Results: In the dental and orthopedic department, the puncture incidence were significantly higher than others. The time of wearing gloves demonstrated significant difference: The group 181-240 minutes had a significantly higher than those with under 90, 91-180, or over 240 minutes. The influencing factors were as follows. Compared to that of the 2nd assistants, the puncture incidence rates of the surgeons were 9.91 times, scrub nurses were 8.39 times higher respectively. The participants in work experience under 1 year showed a 4.58 times higher than those with over 7 years. In addition, compared to the puncture incidence rate of neurosurgery department, the 17.41 times in cardio-thoracic surgery, 13.89 times in dental surgery, 4.93 times in gynecology, and 4.97 times in orthopedics higher respectively. Conclusion: There is a need for training operational room personnels to occasionally exchange the gloves even during the procedure and to use double surgical gloves.

AICPS Management Network Integration (PC 통신 서비스 상호 접속 시스템(AICPS)의 통합 관리망)

  • Hong, Yong-Pio;Yun, Sung-Je;Lee, Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.11-21
    • /
    • 1999
  • Physically, AICPS consists of HSSF(High Speed Switching Fabric) and various types of service interface modules to support services of homogeneous communication networks. Functionally, AICPS consists of UANS(User Access Network Subsystem) to connect users with communication networks, IDNS(Information Delivery Network Subsystem) to connect Information-Providers with information delivery network, and LOMS(Local Operations and Management System to manage AICPS. This paper describes the structures of LOMS, ONAS(Operational Network Access Subsystem), which interfaces between LOMS and HSSF, and describes reliability improvement algorithms and construction methods of nationwide management structure of AICPS.

  • PDF

Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(I) - Determination of Optimum Operational Conditions in Lime Adding Process (소석회와 CO2를 이용한 상수관로의 부식제어(I) - 소석회 주입공정의 최적 운전인자 도출)

  • Sohn, Byung-Young;Byun, Kyu-Sik;Kim, Young-Il;Lee, Doo-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.373-378
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to determine the optimum operational condition in lime adding process in water treatment plant(WTP). The mixing time at dissolution tank and sedimentation time at saturator for maintaining optimal turbidity condition of lime supernatant were 60~75 minutes and 75~95 minutes, respectively. There was no difference according to $CO_2$ adding methods such as $CO_2$ saturated water or $CO_2$ gas. But, $CO_2$ saturated water could be convenience at WTP in terms of pH control and quantitative dosing. To minimize generation of calcium carbonate products, the short time interval between adding of lime and $CO_2$ is most important. The lime should be added below 32 mg/l for preventing pH rising and generation of calcium carbonate products at the heating condition.

Effects of Pretreatment Time and pH low set value on Continuous Mesophilic Hydrogen Fermentation of Food Waste (열처리 시간과 pH 하한값이 음식물쓰레기 연속 중온 수소 발효에 미치는 영향)

  • Kim, Sang-Hyoun;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.343-348
    • /
    • 2011
  • Since 2005, food waste has been separately collected and recycled to animal feed or aerobic compost in South Korea. However, the conventional recycling methods discharge process wastewater, which contain pollutant equivalent to more than 50% of food waste. Therefore, anaerobic digestion is considered as an alternative recycling method of food waste to reduce pollutant and recover renewable energy. Recent studies showed that hydrogen can be produced at acidogenic stage in two-stage anaerobic digestion. In this study, the authors investigated the effects of pretreatment time and pH low set value on continuous mesophilic hydrogen fermentation of food waste. Food waste was successfully converted to $H_2$ when heat-treated at $70^{\circ}C$ for 60 min, which was milder than previous studies using pH 12 for 1 day or $90^{\circ}C$. Organic acid production dropped operational pH below 5.0 and caused a metabolic shift from $H_2/butyrate$ fermentation to lactate fermentation. Therefore, alkaline addition for operational pH at or over 5.0 was necessary. At pH 5.3, the result showed that the maximum hydrogen productivity and yield of 1.32 $m^3/m^3$.d and 0.71 mol/mol $carbohydrate_{added}$. Hydrogen production from food waste would be an effective technology for resource recovery as well as waste treatment.

Survey on Teachers' Perception and Operational State for Elementary Science Online Remote Classes (초등 과학 온라인 수업 운영에 대한 교사들의 인식과 운영실태)

  • Kim, Hye-Ran;Choi, Sun-Young
    • Journal of Korean Elementary Science Education
    • /
    • v.39 no.4
    • /
    • pp.522-532
    • /
    • 2020
  • The aims of this study were to do a survey on teachers' perception and operational state for elementary science online remote classes and suggest ways to improve the elementary science online remote classes. The survey was based on responses from 100 teachers who have taught elementary science online remote classes for the first semester of 2020 for COVID-19. The questionnaire used in this study consisted of four parts: general informations of participants, the operation status of elementary science online remote classes, teachers' perceptions on the operation of elementary science online remote classes, ways to improve elementary science online remote classes. As a result of this study, elementary teachers taught elementary science online remote classes on the main use of content utilization type. And they had a difficulty in conducting elementary science online remote classes because of lack of contents, absence of elementary science online remote classes teaching methods, learner management and heavy workload. Therefore, to improve elementary science online remote classes the Ministry of Education and regional offices of education have to develop and provide high-quality contents reflect the characteristics of elementary science subjects, introduce a rent-an-experiment equipment system, and build a science class platform providing frequent real-time interaction between teacher and student.

Study on Applicability of Household Fuel Cell System with Operating Methods (운전방법에 따른 가정용 연료전지 시스템의 적용성 검토)

  • Park, Deaheum;Cha, Kkwangseok;Jung, Younguan
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.2
    • /
    • pp.139-144
    • /
    • 2014
  • A Fuel Cell is one of the solving to reduce greenhouse gases. Despite the high efficiency and environmental friendly of Household Fuel Cell System it has hardly obtained popularity mainly due to its high prices. In order to encourage use of the system prices and operational expenses need to become economical. In this study, optimization through simulation was conducted to find out the optimal operational condition. As a result of simulation the system is operated with DSS operation from 5 O'clock until 19 O'clock for 13 hours at the constant output of 0.4kW to maximize reduction of energy rate. Furthermore, instead of the domestic system with the rated output of 1kW, rated output of the system should be reduced to 0.4 - 0.6kW which can promote installation of household Fuel Cell System.

Hydro-structural issues in the design of ultra large container ships

  • Malenica, Sime;Derbanne, Quentin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.983-999
    • /
    • 2014
  • The structural design of the ships includes two main issues which should be checked carefully, namely the extreme structural response (yielding & buckling) and the fatigue structural response. Even if the corresponding failure modes are fundamentally different, the overall methodologies for their evaluation have many common points. Both issues require application of two main steps: deterministic calculations of hydro-structure interactions for given operating conditions on one side and the statistical post-processing in order to take into account the lifetime operational profile, on the other side. In the case of ultra large ships such as the container ships and in addition to the classical quasi-static type of structural responses the hydroelastic structural response becomes important. This is due to several reasons among which the following are the most important: the increase of the flexibility due to their large dimensions (Lpp close to 400 m) which leads to the lower structural natural frequencies, very large operational speed (> 20 knots) and large bow flare (increased slamming loads). The correct modeling of the hydroelastic ship structural response, and its inclusion into the overall design procedure, is significantly more complex than the evaluation of the quasi static structural response. The present paper gives an overview of the different tools and methods which are used in nowadays practice.

A Study on Operational Characteristics of DC protective relay systems on the Subway (지하철 직류보호계전시스템의 동작특성에 관한 연구)

  • Jung, Hyun-Ki;Jung, Jong-Jin;An, Tae-Pung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.451-465
    • /
    • 2008
  • The DC over current relay(76i) and the DC under voltage relay(mid-point relay, 80A) used mainly with DC protective relay system of DC electric railway in Korea, But the DC fault selective relay(50F) is applying to recently mainly. In this study, simulation to compare 76i/80A and 50F in the methods of protection and the operational characteristics were executed through verifying a calculation of short circuit current and using PSCAD/EMTDC transition program. As a result of this study, it was proved that while 80A runs in relation to the scale of fault resistance, 50F runs regardless of the scale of fault resistance or the length of rail.

  • PDF

Conservation Concept Among Rural Children in Korea (우리나라 농촌아동(農村兒童)의 발달단계별(發達段階別) 보존(保存)개념)

  • Cho, Bok Hee
    • Korean Journal of Child Studies
    • /
    • v.2
    • /
    • pp.41-53
    • /
    • 1981
  • The purpose of this study was to find out conservation concept acquisition in children of pre-operational and concrete periods. The data in this study were obtained through experimental methods with 62 children(28 males and 34 females) of 3-11 ages in Korean rural areas. The Piagetian instruments devised by Gelman were used for the study ; length, liquid, quantity, mass, and volume conservation tasks. Percentile and $x^2$-test were applied for the statistical analysis of data: and the results of the experiment are as follows: 1) Most children aged 3-9 years did not appear to understand that the length of sticks stayed the same regardless of position. 2) In liquid quantity conservation, children centered their attentions on one aspect ; juice level or number of container. Their conservation concept was developed correlating with ages. 3) In the experiment of mass conservation by using play dough, only 7.1% of children of pre-operational period and 47.1% of concrete period affirmed that the amounts of play dough were same after changed shape. 4) In volume task, 29.4% children aged 7 to 11 years admitted to conservation. 5) It is found that girls acquired length conservation earlier than boys, while there was no significant difference between boys and girls in other conservation tasks.

  • PDF

Effect of Operational Parameters on the Removal of Microcystis aeruginosa in Electro-flotation Process

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1417-1426
    • /
    • 2016
  • Despite the low removal efficiencies reported by previous studies, electro-flotation still stands out among other microalgae removal methods for its economical and environmental benefits. To enhance removal efficiency, the important factors that limit the performance of this method must be investigated. In this study, the possible ways of increasing the removal efficiency of microalgae have been explored by investigating the effects of several important variables in electro-flotation. Eight parameters, namely flotation time, rising time, current density, pH, conductivity, electrode distance, temperature and initial concentration were evaluated using a one-parameter-at-a-time approach. Results revealed that the operational parameters that greatly affected the removal efficiency of microalgae were electro-flotation time, current density, pH, and initial concentration. The effect of conductivity, electrode distance, and temperature on removal efficiency were insignificant. However, they exhibited positive an indirect positive effect on power demand, which is nowadays considered an equally important aspect in the running of a feasible and economically efficient electro-flotation process.