• 제목/요약/키워드: operation research

검색결과 12,992건 처리시간 0.042초

$\cdot$ 대용량 인버터용 IGBT 병렬 운전 연구 (The Study on Parallel operation of IGBT for the Medium SE the Large capacity Inverter)

  • 박건태;윤재학;정명길;김두식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.430-433
    • /
    • 2003
  • IGBTS are widely used for the industrial inverters in the mid power range at low voltage (440V$\~$660V) application. Advantageous features of the device are simple gate drive and high speed switching capability. Due to these advantages the application of IGBTS is enlarging into the high power application. However, to increase the power handling capacity at lower input voltage level, the current rating in each bridge arm must be enlarged. Therefore the parallel operation of IGBT devices is essentially needed. This paper describes the feasible parallel structures of the power circuit for the mid & the high power inverters and introduces the important design condition for the parallel operation of IGBT devices. To verify feasibility of the IGBT parallel operation, the feature of several IGBT devices (EUPEC, SEMIKRON's IGBT) are investigated and the power stacks are implemented and tested with these devices. The experimental results show the good characteristics for the parallel operation of IGBTS.

  • PDF

기관평가제도 운영의 영향요인에 관한 연구 -과학기술계 정부출연연구기관을 중심으로- (A Study on Factors that Influence Institution Evaluation in Korea - With a focus on Government Research Institutes in the Field of Science and Technology -)

  • 이길우
    • 기술혁신학회지
    • /
    • 제8권spc1호
    • /
    • pp.525-554
    • /
    • 2005
  • The purpose of this paper is to seek out the problems influencing on the operation of Institution Evaluation(IE) in Korea and suggest a better way for the evaluation based on the findings, expecially focusing on Government Research Institute(GRIs) in the field of Science and Technology. Unlike previous studies on IE of GRIs, this research is more oriented toward actual practices than design and theories of IE. Three categories are 1) purely system aspect, 2) system-operation aspect, and 3) environmental aspect. These three categories are classified into eight sub-categories: 1) the legal support and the legally enforceable provision, 2) the target area of evaluation, 3) the means and process of evaluation, 4) the criteria and indices for evaluation, 5) the expertise of evaluators, 6) the use of evaluation findings, 7) GRIs' support for IE, and 8) public support for IE. Summing up the findings of this study, the main factors that hamper the successful operation of the existing IE of GRIs in the field of Science and Technology was illuminated and the better way for the operation of IE was suggested.

  • PDF

원격 로봇 비주얼 가이던스를 위한 가상벽 가시화 방법론 비교 (Methodological Comparison of Visualization for Tele-operated Robot Visual Guidance)

  • 김동엽;신동인;황정훈;김영욱
    • 제어로봇시스템학회논문지
    • /
    • 제22권11호
    • /
    • pp.877-882
    • /
    • 2016
  • Disaster robots have accepted tele-operation in order to share the intelligence of human operators and robot systems. Virtual wall is one of the tele-operation technology to support recognition of human operator. If the virtual wall can block the robot from dangers, the operator will feel comfortable and can concentrate on fundamental missions. In this paper, we proposes and compares three methods for virtual wall visualization in tele-operation using 3D reconstruction. First is a virtual wall visualized only with edges. A wall filled with transparent color is the second method. Finally, third method is a texture-mapped virtual wall. In the experiments, we discuss their merits and demerits in view of robot tele-operation.

Operation optimization of auxiliary electric boiler system in HTR-PM nuclear power plant

  • Du, Xingxuan;Ma, Xiaolong;Liu, Junfeng;Wu, Shifa;Wang, Pengfei
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2840-2851
    • /
    • 2022
  • Electric boilers (EBs) are the backup steam source for the auxiliary steam system of high-temperature gas-cooled reactor nuclear power plants. When the plant is in normal operations, the EB is always in hot standby status. However, the current hot standby operation strategy has problems of slow response, high power consumption, and long operation time. To solve these problems, this study focuses on the optimization of hot standby operations for the EB system. First, mathematical models of an electrode immersion EB and its accompanying deaerator were established. Then, a control simulation platform of the EB system was developed in MATLAB/Simulink implementing the established mathematical models and corresponding control systems. Finally, two optimization strategies for the EB hot standby operation were proposed, followed by dynamic simulations of the EB system transient from hot standby to normal operations. The results indicate that the proposed optimization strategies can significantly speed up the transient response of the EB system from hot standby to normal operations and reduce the power consumption in hot standby operations, improving the dynamic performance and economy of the system.

Study on operation stability of printed organic TFTs

  • Kamata, T.;Suemori, K.;Yoshida, M.;Uemura, S.;Hoshino, S.;Kozasa, T.;Takada, N.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1216-1219
    • /
    • 2007
  • We have been developing printed organic TFTs for flexible displays. In this study, we have pay attention to the operation stability improvement of the organic TFTs, and studied several factors especially depending on the dielectric layers. From the detailed analysis of the effects of dielectric layers, we have proposed a new printed dielectric layer which is mainly consisting of metal oxide and gives high operation stability

  • PDF

A Study on Using Large-Scale Energy Storage Systems in Automatic Generation Control Operations of the Energy Management Systems

  • Im, Jihoon;Lim, Gunpyo;Park, Chanwook;Choi, Yohan;Kim, Seunghan;Chang, Byunghoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.121-125
    • /
    • 2016
  • KEPCO has completed the installation and demonstration of a 52 MW battery energy storage system (BESS) for frequency regulation. Especially, 24 MW BESS is for Automatic Generation Control (AGC) in Shin-Yongin substation. Recently, KEPCO Research Institute has operated it connected to EMS of KPX. This paper discussed the operation strategy of EMS through a study on using 24 MW BESS in AGC operation and propose the improvement of AGC target. It is expected that this paper helps a safe and reliable operation and control of ESS for AGC through its continuous update.

주파수조정용 배터리 에너지저장장치 운전방법의 개발과 적용 (Development and Application of Operation Methods of Battery Energy Storage System for Frequency Regulation)

  • 임건표;박두용
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.57-61
    • /
    • 2015
  • Current research and development efforts and other projects for energy storage systems (ESS) have recently been gaining attention. This is due to the many applications where ESS, particularly batteries, can be used. Among these are peak shaving, frequency regulation, and stabilization of renewable energy output. KEPCO has completed the construction and demonstration of a 4-MW battery energy storage system (BESS) located in Jeju City to verify its practicability in the power grid. KEPCO Research Institute has also been developing technology for the commercialization of BESS, and has been conducting a trial run of a 52-MW ESS (28MW + 24MW of Seo-Anseong and Shin-Yongin substations) constructed in 2014 for frequency regulation. This paper discusses the development of operation methods, as well as an operation user interface, for the safe operation and monitoring of BESS used for frequency regulation in a power system. Included are operation and simulation methods for various normal and transient frequency situations that can be experienced by a power system. Also discussed are the results obtained after applying these methods to the 4-MW BESS and the 52-MW ESS, both used for frequency regulation. The technology in this paper will be applied to 500MW ESS for frequency regulation of KEPCO by 2017. It is expected that this technology helps a safe and reliable operation and control of ESS for frequency regulation through its continuous upgrade.

An Analysis of Fraction Operation Sense to Enhance Early Algebraic Thinking

  • Lee, Jiyoung;Pang, Jeongsuk
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제16권4호
    • /
    • pp.217-232
    • /
    • 2012
  • While many studies on early algebra have been conducted, there have been only a few studies on the operation sense as the fundamental element of algebraic thinking, especially the fraction operation sense. This study explored the dimensions of fraction operation sense and then investigated students' fraction operation sense. A total of 183 of sixth graders were surveyed and 5 students who showed high operation sense were clinically interviewed in order to analyze their algebraic thinking in detail. The results showed that students had a tendency to use direct calculation or employ inappropriate operation sense rather than to use the structure of operation or the relation between operations on the basis of algebraic thinking. This study implies that explicit instruction on early algebra is necessary from the elementary school years.

Chromatic Dispersion Compensation via Mid-span Spectral Inversion with Periodically Poled $LiNbO_3$ Wavelength Converter at Low Pump Power

  • Kim, Min-Su;Ahn, Joon-Tae;Kim, Jong-Bae;Ju, Jung-Jin;Lee, Myung-Hyun
    • ETRI Journal
    • /
    • 제27권3호
    • /
    • pp.312-318
    • /
    • 2005
  • Mid-span spectral inversion (MSSI) has to utilize high optical pump power, for its operation principle is based on a nonlinear optical wavelength conversion. In this paper, a low pump-power operation of MSSI-based chromatic dispersion compensation (CDC) has been achieved successfully, for the first time to our knowledge, by introducing a noise pre-reduction scheme in cascaded wavelength conversions with periodically poled $LiNbO_3$ waveguides at a relatively low operation temperature. As preliminary studies, phase-matching properties and operation-temperature dependence of the wavelength converter (WC) were characterized. The WC pumped at 1549 nm exhibited a wide conversion bandwidth of 59 nm covering the entire C-band and a conversion efficiency of -23.6 dB at 11 dBm pump power. CDC experiments were implemented with 2.5 and 10 Gb/s transmission systems over 100 km single-mode fiber. Although it is well-known that the signal distortion due to chromatic dispersion is not critical at a 2.5 Gb/s transmission, the clear recovery of eye patterns was identified. At 10 Gb/s transmission experiments, eye patterns were retrieved distinctly from seriously distorted ones, and notable improvements in bit-error rates were acquired at a low pump power of 14 dBm.

  • PDF