• Title/Summary/Keyword: operation principle

Search Result 896, Processing Time 0.075 seconds

An Analysis on the Instructional Contents by Intuitive Principles in Elementary Mathematics (초등수학에서 직관적 원리에 의한 교육 내용 분석)

  • Lee, Dae-Hyun
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.15 no.2
    • /
    • pp.283-300
    • /
    • 2011
  • Since elementary students are in the concrete operational stages, they have to learn mathematics using intuitive methods such as visualization, observation, operation, experiment instead of formal approach. For this, we should present the various intuitive methods in curriculum and textbook. It is because that curriculum and textbook are important tools to students when they study mathematics. So, this paper intended to analyze the instructional content by intuitive principle in elementary mathematics curriculum, textbook and curriculum guide. The results are as follows: there is an intuitive principle in only character of mathematics in curriculum. I can't find the intuitive principle in other areas in curriculum. There are 12 intuitive principles in figures area, 1 in measurement area, and 2 in probability and statistics area in curriculum guide. But intuitive principles which are used are inclined to restricted to intuitive principle via representation obtained in the usual experience. Finally, I suggest some implications about teaching via intuitive principles, curriculum, and writing textbook based on the this findings.

  • PDF

A Study on Non-documentary Condition in L/C Transactions (신용장상 서류비지정조건의 취급에 관한 소고)

  • Kim, Ki-Sun;Kim, Young-Hoon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.42
    • /
    • pp.109-132
    • /
    • 2009
  • The purpose of the introduction of this article is as follows. It was frequent to put a condition on the letter of credit without stating corresponding document. But these attempts are very dangerous to the letter of credit operation. That is, if these types of conditions would be permitted in letter of credit, the independence principle must be collapsed. So these conditions must be disregarded in order to safeguard the independence principle. It is why UCP600 article 14(h) writes that if a Credit contains a condition without stating the document(s) to be presented in compliance therewith, banks will deem such conditions as not stated and will disregard it. But scope of this article 14 should not be limited by the conditions which do not state the document to be presented in compliance therewith. That is, the purpose of this article is to preserve the independence principle, so, if it is impossible to ascertain satisfaction with a condition, it should be disregarded as the non-documentary condition, even if the condition is included in the letter of credit together with document to be presented. Conclusively, whether or not a condition would be regarded as the non documentary condition depends on whether compliance of such condition is ascertained by presented documents stipulated in the letter of credit.

  • PDF

High-accuracy quantitative principle of a new compact digital PCR equipment: Lab On An Array

  • Lee, Haeun;Lee, Cherl-Joon;Kim, Dong Hee;Cho, Chun-Sung;Shin, Wonseok;Han, Kyudong
    • Genomics & Informatics
    • /
    • v.19 no.3
    • /
    • pp.34.1-34.6
    • /
    • 2021
  • Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter (기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성)

  • 원종수;정의상
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

Optimal Operation Design of Continuous Enzymatic Reactor System (연속효소반응장치의 최적반응조작설계)

  • Namkoong, Shik
    • Microbiology and Biotechnology Letters
    • /
    • v.2 no.2
    • /
    • pp.63-77
    • /
    • 1974
  • The optimal operation problem of enzyme reactor of double inhibitions are dealt with Maximum Principle and Steepest Ascent Method. The operation policy of the intial concentration and amount of substrate, reaction time and the method of cross feed of substrate are determined in a system of reactor of constant volume add with cross feed of substrate. The policy for the soluble enzyme and the immobilized enzyme are greatly different from each other, and the performance index, the profit per unit time, of the latter are nearly twice greater than that of the former.

  • PDF

A Control Scheme of Recloser for Asymmetrical Fault Current Reduction (비대칭 고장전류 저감을 위한 재폐로 차단기 제어 방안)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Seo, Hun-Chul;Ko, Yun-Tae;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.215_216
    • /
    • 2009
  • This paper presents a asymmetry fault current reduction scheme with recloser operation during transient period. The principle of asymmetry current nature is reviewed and asymmetry components reduction with recloser operation is explained. Throughout the simulation, results verifies the proposed scheme for recloser operation and its effectiveness.

  • PDF

An Analysis of Superconducting Fault Current Limiter Operation According to Asymmetry Fault Current (비대칭 고장전류에 따른 초전도 한류기 동작 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.450-454
    • /
    • 2009
  • This paper analyzes a asymmetry current with SFCL (Superconducting Fault Current Limiter) operation during transient period, when a fault occurs in power systems. The principle of asymmetry current nature is reviewed and asymmetry components reduction with SFCL operation is explained. To verify the performance of SFCL, a EMTP/ATPDraw model of SFCLs using MODELS language developed and simulated. Throughout the simulation, results presents the main factors for reducing the asymmetry component of fault current are not a quenching time, but a limiting resistance of SFCL and fault initiated angle.

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Optimal Planning for Dispersed Generating Sources in Distribution Systems (배전계통에 있어서 열병합 분산형전원의 최적 도입계획에 관한 기초적 연구)

  • Shim, Hun;Rho, Dae-Seok;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.513-515
    • /
    • 2000
  • This paper deals with a method for determining an optimal operation strategy of dispersed generating sources considering thermal merits. The optimal operation of these sources can be determined by the principle of equal incremental fuel cost. This paper presents an optimal operation strategy using the Kuhn-Tucker's optimal conditions and also an priority method to decide the optimal location of those sources in power systems. The validity of the proposed algorithms are demonstrated using a model system.

  • PDF

Nonisolated Bidirectional ZVT DC-DC Converter for an Energy Storage System (에너지 저장 시스템을 위한 비절연 양방향 ZVT DC-DC 컨버터)

  • Han, Ji-tai;Lim, Chang-soon;Kim, Rae-young;Hyun, Dong-seok
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.50-51
    • /
    • 2012
  • The paper presents a non-isolated bidirectional DC-DC converter for use in renewable power generation, battery, electric vehicles (EV) and small scale DC-UPS systems. In the propose design, the conventional interleaved operation of two-inductor boost structure is modified to accommodate bidirectional operation, and zero-voltage-transition (ZVT) is applied, where both the switch and the rectifier diode achieve soft condition without increasing their voltage and current stresses. The proposed converter has the merits of simple circuitry, reduced size, low cost and high efficiency. The operation principle of the converter is analyzed and verified. Also, simulation results of the proposed bidirectional dc-dc converter is shown.

  • PDF