• Title/Summary/Keyword: operating temperature

Search Result 3,666, Processing Time 0.034 seconds

Characteristics of Bunsen Reaction using Ultrasonic Irradiation in Sulfur-iodine Hydrogen Production Process (황-요오드 수소 제조 공정에서 초음파 조사를 이용한 분젠 반응의 특성)

  • Kim, Hyo Sub;Lee, Dong Hee;Lee, Jong Gyu;Park, Chu Sik;Kim, Young Ho
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.56-61
    • /
    • 2018
  • In Bunsen reaction section for the integrated operation of sulfur-iodine (SI) process, $I_2$ and $H_2O$ reactants are supplied as dissolved species in an $HI_x$ solution. Most of the $H_2SO_4$ product is found in the $HI_x$ phase when Bunsen reaction is performed using the $HI_x$ solution and $SO_2$ feed, so that the volume ratio of the $H_2SO_4$ phase to the $HI_x$ phase is very low. In this study, we investigated the effects of ultrasound irradiation on Bunsen reaction using the $HI_x$ solution to improve its phase separation performance. With ultrasound irradiation, the amount of $H_2SO_4$ moved to the $H_2SO_4$ phase from the $HI_x$ phase increased by up to 58.0 mol% and the volume of $H_2SO_4$ phase also increased by up to 13.1 vol%. In particular, the effect of ultrasound irradiation on the phase separation was improved with decreasing operating temperature, $I_2$ and $H_2O$ feed concentrations. The ultrasound irradiation induces the formation of additional $H_2O$ molecules by shifting microscopically the reaction equilibrium in the $HI_x$ phase. Afterward, the additionally generated $H_2O$ and isolated $H_2SO_4$ molecules form more $H_2SO_4{\cdot}xH_2O$ (x = 5-6) clusters that can be moved to the $H_2SO_4$ phase.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Comparative Study on the Estimation of CO2 absorption Equilibrium in Methanol using PC-SAFT equation of state and Two-model approach. (메탄올의 이산화탄소 흡수평형 추산에 대한 PC-SAFT모델식과 Two-model approach 모델식의 비교연구)

  • Noh, Jaehyun;Park, Hoey Kyung;Kim, Dongsun;Cho, Jungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.136-152
    • /
    • 2017
  • The thermodynamic models, PC-SAFT (Perturbed-Chain Statistical Associated Fluid Theory) state equation and the Two-model approach liquid activity coefficient model NRTL (Non Random Two Liquid) + Henry + Peng-Robinson, for modeling the Rectisol process using methanol aqueous solution as the $CO_2$ removal solvent were compared. In addition, to determine the new binary interaction parameters of the PC-SAFT state equations and the Henry's constant of the two-model approach, absorption equilibrium experiments between carbon dioxide and methanol at 273.25K and 262.35K were carried out and regression analysis was performed. The accuracy of the newly determined parameters was verified through the regression results of the experimental data. These model equations and validated parameters were used to model the carbon dioxide removal process. In the case of using the two-model approach, the methanol solvent flow rate required to remove 99.00% of $CO_2$ was estimated to be approximately 43.72% higher, the cooling water consumption in the distillation tower was 39.22% higher, and the steam consumption was 43.09% higher than that using PC-SAFT EOS. In conclusion, the Rectisol process operating under high pressure was designed to be larger than that using the PC-SAFT state equation when modeled using the liquid activity coefficient model equation with Henry's relation. For this reason, if the quantity of low-solubility gas components dissolved in a liquid at a constant temperature is proportional to the partial pressure of the gas phase, the carbon dioxide with high solubility in methanol does not predict the absorption characteristics between methanol and carbon dioxide.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure (젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구)

  • Kang, Ho;Kim, Sun-Woo;Jeong, Ji-Hyun;Ahn, Hee-Kwon;Jung, Kwang-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.696-704
    • /
    • 2015
  • This study was carried out to evaluate the optimum operational condition of Semi-continuously Fed and Mixed Reactor (SCFMR) to treat the dairy cow manure and saw dust mixture. Step-wise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) were utilized until the biogas volume became significantly decreased at mesophilic temperature ($35^{\circ}C$). The optimum operating condition of the SCFMR fed with TS 13% dairy cow manure and saw dust mixture was found to be an HRTs of 25 days and its corresponding OLRs of $4.45kg\;VS/m^3-day$. At this condition the biogas and methane production rates were 1.44 v/v-d and 1.12 v/v-d (volume of biogas per volume of reactor per day), respectively and the TVS removal efficiency of 37% was achieved. The successful operation with such a high OLR was due to the high reactor alkalinity concentration of 14,500~15,600 mg/L as $CaCO_3$ as a result of the characteristic of the original substrate, dairy cow manure and saw dust mixture whose alkalinity was more than 8,000 mg/L as $CaCO_3$. The parameters for the reactor stability, the ratios of volatile acids and alkalinity concentrations (V/A) and the ratio of propionic acid and acetic acid concentrations (P/A) appeared to be 0.11 and 0.43, respectively, that were greatly stable in operation. Free ammonia toxicity was not experienced due to the long term acclimation by the reactor TS content ranged 7.2~10.4% during the entire operational period.

A Comparison of Three Suture Techniques on Adhesion in End-to-end Intestinal Anastomosis of Dogs (개에서 세가지 단단장문합 봉합법에 따른 유착비교)

  • Kim, Je-Sun;Jeong, Soon-Wuk;Kim, Joon-Young;Jeong, Man-Bok;Han, Hyun-Jung
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • In this study, we evaluated effects of three anastomotic techniques of small intestine on adhesions in the dog. Twenty six healthy mixed dogs were randomly assigned to three groups. Group I(n = 8) was sutured with a simple continuous suture, group II(n = 7) was sutured with a simple interrupted approximating suture and group III(n = 11) was sutured with a single layer continuous Connell suture. On completion of any intestinal anastomosis, a pedicle of greater omentum was wrapped around the suture line in all experimental dogs. One percent sodium carboxymeth-ylcellulose (5ml/kg) was administrated into the abdomen by feeding tube prior to closing the last part of peritoneum in all dogs. Postoperative adhesions were evaluated at 14th day after operation. The adhesions consisted primarily in two dogs in group I, three dogs in group II and group III. There were adhesions between intestinal serosal surfaces in eight dogs in all groups, but there were no intestinal serosa-visceral peritoneum adhesion and intestinal serosa-mesentery adhesion. Mean adhesion scores were less than score 2 in all groups. Between anastomotic site and omental graft, there were 13.13$\pm$4.97 mm (mean$\pm$S.D.) adhesion formation in group I and 17.29$\pm$4.68 mm in group II and 14.64$\pm$3.80mm in group III. A simple continuous suture resulted in the least adhesion formation and a simple interrupted approximating suture resulted in the greatest adhesion formation among the groups. However, there were no significant differences among three suture techniques in the severity of adhesions. Intestinal intussusception only encountered in one dog during the 14 days, the dog operated and survived. Daily monitoring of temperature, activity, appetite, defecation and micturition were done. All of those vital signs were within normal values and there were no obvious differences among the groups. In conclusion, even though there were no significant differences among three groups, a simple continous suture pattern is recommended to prevent adhesions when operating intestinal anastomosis in dogs.

Anti-stress effects of Herbal Acupuncture by Soyo-san on ovariectomized rats (소요산(逍遙散) 약침(藥鍼)이 난소적출 흰쥐의 항(抗)스트레스 작용(作用)에 미치는 영향(影響))

  • Oh, Seung-hee;Park, Hyun-jung;Hahm, Dae-hyun;Shim, In-sop;Lee, Hye-jung
    • Journal of Acupuncture Research
    • /
    • v.22 no.1
    • /
    • pp.117-130
    • /
    • 2005
  • Objective : Generation after generation, by Oriental medicine literatures, Soyo-san has been used as a clinical prescription that is important to climacteric syndrome, and also has been used extensively to psyco-neurotic problems, melancholia and stress symptoms. The experimental study of Soyo-san's effect has been reported, but the effect of herbal acupuncture solution by Soyo-san is not reported yet. Thus the purpose of this experiment is to test whether Herbal acupuncture of Soyo-san have anti-stress or antidepressant effects in the menopause or not. Methods : Female Sprague-Dawley(240-260g) rats were used. Temperature controlled within $20-25^{\circ}C$. Water and food not limited, and Manipulated the day and night 12 hours each. In the experiment, enforced Morris water maze after immobilization stress for 5 minutes, and operating Herbal acupuncture of Soyo-san 30 minutes before stress every day during 7 days. Flowed through by 4% paraformaldehyde and fixed brain tissue after test of 7 days. Results : 1) As a result of the acquisition test, Soyo-san group was recognized by significant difference compared to Ovx group and the retention test Soyo-san group increased significantly compared to Sham and Ovx group. 2) Soyo-san group showed that the degree of revealation of Tyrosine hydroxylase decreased comparing to Ovx group in ventral tegmental area and that of Choline acetyltransferase increased comparing to Ovx group in CAI region of Hippocampus. Conclusion : As a result of this experiment to grasp those effects on postmenopausal depression or learing disability and memory disorder, the possibility of Herbal acupunture by Soyo-san is warranted as a suitable treatment to relieve women's monopausal depression and those of stress reaction, improving tearing disability and memory disorder.

  • PDF

A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System (위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.77-88
    • /
    • 2000
  • In this paper, the 3-mode variable gain high power amplifier for a transmitter of INMARSAT-B operating at L-band(1626.5-1646.5 MHz) was developed. This SSPA can amplify 42 dBm in high power mode, 38 dBm in medium power mode and 36 dBm in low power mode for INMARSAT-B. The allowable errol sets +1 dBm as the upper limit and -2 dBm as the lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier. The HP's MGA-64135 and Motorola's MRF-6401 were used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 for the high power amplifier. The SSPA was fabricated by the RP circuits, the temperature compensation circuits and 3-mode variable gain control circuits and 20 dB parallel coupled-line directional coupler in aluminum housing. In addition, the gain control method was proposed by digital attenuator for 3-mode amplifier. Then il has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. In this case, the SSPA detects the output power by 20 dB parallel coupled-line directional coupler and phase non-splitter amplifier. The realized SSPA has 41.6 dB, 37.6 dB and 33.2 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.3:1. The minimum value of the 1 dB compression point gets more than 12 dBm for 3-mode variable gain high power amplifier. A typical two tone intermodulation point has 36.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.

  • PDF

Predictors of Meningitis in Febrile Infants Aged 3 Months or Younger (열이 있는 3개월 이하의 영아에서 수막염의 예측에 대한 연구)

  • Song, Hyang Soon;Kim, Eun Ok;Jang, Young Taek
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to identify useful predictors for diagnosing bacterial meningitis and performing CSF studies in febrile infants three months or younger. Methods : Six hundred and fifty two febrile infants with a rectal temperature ${\geq}38.0^{\circ}C$ presented from January 2003 to April 2008 and were retrospectively studied. The total white blood cell count (WBC), band count, absolute neutrophil count (ANC), quantitative C-reactive protein (CRP) and blood cultures were performed on admission. The clinical variables associated with bacterial meningitis were analyzed. Results : In patients with bacterial meningitis, the clinical variables including CRP (P=0.036), band count (P=0.037), ANC (P=0.036) and age (P=0.001) were significantly different. The area under the receiver-operating characteristic curve was 0.969 for CRP, 0.946 for the band count, 0.765 for the ANC and 0.235 for age. A CRP cutoff point of 8 mg/dL was determined to maximize both the sensitivity and specificity (sensitivity 83%, specificity 95%, likelihood ratio 16.6). A CRP concentration of <7 mg/dL "ruled-out" bacterial meningitis, with a likelihood ratio of 0.17, a posttest probability of <0.1% and negative predictive value 91%. A CRP concentration greater than 9 mg/dL had a much higher likelihood ratio (20.1) than the band count (16.6) and ANC (2.2). Conclusion : The CRP concentration was a useful laboratory test for the differential diagnosis of bacterial meningitis among febrile infants three months of age or younger. A CRP concentration of <7 mg/dL effectively ruled out bacterial meningitis; a value ${\geq}9mg/dL$ increased the clinical suspicion of bacterial meningitis and the need for CSF evaluation.

  • PDF

Comparative Analysis of GNSS Precipitable Water Vapor and Meteorological Factors (GNSS 가강수량과 기상인자의 상호 연관성 분석)

  • Jae Sup, Kim;Tae-Suk, Bae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.317-324
    • /
    • 2015
  • GNSS was firstly proposed for application in weather forecasting in the mid-1980s. It has continued to demonstrate the practical uses in GNSS meteorology, and other relevant researches are currently being conducted. Precipitable Water Vapor (PWV), calculated based on the GNSS signal delays due to the troposphere of the Earth, represents the amount of the water vapor in the atmosphere, and it is therefore widely used in the analysis of various weather phenomena such as monitoring of weather conditions and climate change detection. In this study we calculated the PWV through the meteorological information from an Automatic Weather Station (AWS) as well as GNSS data processing of a Continuously Operating Reference Station (CORS) in order to analyze the heavy snowfall of the Ulsan area in early 2014. Song’s model was adopted for the weighted mean temperature model (Tm), which is the most important parameter in the calculation of PWV. The study period is a total of 56 days (February 2013 and 2014). The average PWV of February 2014 was determined to be 11.29 mm, which is 11.34% lower than that of the heavy snowfall period. The average PWV of February 2013 was determined to be 10.34 mm, which is 8.41% lower than that of not the heavy snowfall period. In addition, certain meteorological factors obtained from AWS were compared as well, resulting in a very low correlation of 0.29 with the saturated vapor pressure calculated using the empirical formula of Magnus. The behavioral pattern of PWV has a tendency to change depending on the precipitation type, specifically, snow or rain. It was identified that the PWV showed a sudden increase and a subsequent rapid drop about 6.5 hours before precipitation. It can be concluded that the pattern analysis of GNSS PWV is an effective method to analyze the precursor phenomenon of precipitation.