• 제목/요약/키워드: operating temperature

검색결과 3,662건 처리시간 0.03초

보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가 (Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header)

  • 신규인;윤기봉
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.

저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구 (Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat)

  • 조수용;조종현
    • 신재생에너지
    • /
    • 제10권4호
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

고온에서 accumulation-mode Pi-gate p-MOSFET 특성 (High Temperature Characterization of Accumulation-mode Pi-gate pMOSFETs)

  • 김진영;유종근;박종태
    • 대한전자공학회논문지SD
    • /
    • 제47권7호
    • /
    • pp.1-7
    • /
    • 2010
  • Fin 폭이 다른 accumulation-mode Pi-gate p-채널 MOSFET의 고온특성을 측정 분석하였다. 사용된 소자는 Fin 높이는 10nm 이며 폭은 30nm, 40nm, 50nm 의 3종류이다. 온도에 따라서 드레인 전류, 문턱전압, subthreshold swing, 유효이동도 및 누설 전류 특성을 측정하였다. 온도가 증가할수록 드레인 전류는 상온에서 보다 약간 증가하는 현상이 나타났다. 온도에 따른 문턱전압의 변화는 inversion-mode 소자 보다 작은 것으로 측정되었다. 유효이동도는 온도가 증가할수록 감소하였으나 Fin 폭이 감소할수록 이동도는 큰 것을 알 수 있었다.

계절별 운전조건에 따른 수직형 지열교환기의 깊이별 지중온도 변화에 대한 사례 연구 (A Case Study on the Seasonal Temperature Variations in Depth of a Vertically-installed Geothermal Heat Exchange Pipe)

  • 황광일;신동걸;김중헌;신승호
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.45-50
    • /
    • 2009
  • To estimate the operating performances of the geothermal heat exchange pipe(GHEX), GHEXs of 400RT geothermal system were measured and analyzed through a year. The followings are the results. The temperature of 2 GHEXs installed 4m apart was fluctuated very similarly. When the geothermal system is nor operating or is operating as heating mode, the temperature of G.L.-170m was always higher than G.L.-70m's. But it reversed when the geothermal system is operating as cooling mode. And through a year, it has been observed that the temperature of G.L.-170m is increased approximately $1.5^{\circ}C$. With previously mentioned results, the heat transfer capacity of G.L.-70m's geological stratum is estimated as higher than that of the G.L.-170m.

보일러 고온요소의 수명 감시시스템 소프트웨어 개발 (Development of On-line Life Monitoring System Software for High-temperature Components of Power Boilers)

  • 윤필기;정동관;윤기봉
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1999
  • Nondestructive inspection and accompanying life analysis based on fracture mechanics were the major conventional methods for evaluating remaining life of critical high temperature components in power plants. By using these conventional methods, it has been difficult to perform in-service inspection for life prediction. Also, quantitative damage evaluation due to unexpected abrupt changes in operating temperature was almost impossible. Thus, many efforts have been made for evaluating remaining life during operation of the plants and predicting real-time life usage values based on the shape of structures, operating history, and material properties. In this study, a core software for on-line life monitoring system which carries out real-time life evaluation of a critical component in power boiler(high temperature steam headers) is developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperature/stress transfer Green functions derived for the specific headers and by counting transient cycles. The major benefits of the developed software lie in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF

과급을 이용한 저온 디젤 연소의 운전영역 확장 및 연료소비율 저감 (Expansion of Operating Range and Reduction of BSFC in Low Temperature Diesel Combustion with Boosting)

  • 심의준;한상욱;장진영;박정서;배충식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3013-3018
    • /
    • 2008
  • Supercharging system was adopted to investigate the influence of boost pressure on operating range, brake specific fuel consumption (BSFC) and exhaust emissions by using a supercharger at low temperature diesel combustion (LTC) condition in a 5-cylinder 2.7 L direct injection diesel engine. The experimental parameters such as injection quantity, injection timing, injection pressure and exhaust gas recirculation (EGR) rate were varied to find maximum operating range. The result showed that operating range with boost was expanded up to 41.9% compared to naturally aspirated LTC condition due to increased mixing intensity. The boosted LTC engine showed low BSFC value and dramatically reduced soot emission under all operating range compared with high speed direct injection (HSDI) mode. Finally, this paper presents the boosted LTC map of emission and the strategy of improved engine operating range.

  • PDF

실험계획법을 이용한 고온 고분자 전해질 막 연료전지의 운전조건 최적화 연구 (Study on Optimization of Operating Conditions for High Temperature PEM Fuel Cells Using Design of Experiments)

  • 김진태;김민진;손영준
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.50-60
    • /
    • 2013
  • High temperature proton exchange membrane fuel cells (PEMFCs) using phosphoric acid (PA) doped polybenzimidazole (PBI) membranes have been concentrated as one of solutions to the limits with traditional low temperature PEMFCs. However, the amount of reported experimental data is not enough to catch the operational characteristics correlated with cell performance and durability. In this study, design of experiments (DOE) based operational optimization method for high temperature PEMFCs has been proposed. Response surface method (RSM) is very useful to effectively analyze target system's characteristics and to optimize operating conditions for a short time. Thus RSM using central composite design (CCD) as one of methodologies for design of experiments (DOE) was adopted. For this work, the statistic models which predict the performance and degradation rate with respect to the operating conditions have been developed. The developed performance and degradation models exhibit a good agreement with experimental data. Compared to the existing arbitrary operation, the expected cell lifetime and average cell performance during whole operation could be improved by optimizing operating conditions. Furthermore, the proposed optimization method could find different new optimal solutions for operating conditions if the target lifetime of the fuel cell system is changed. It is expected that the proposed method is very useful to find optimal operating conditions and enhance performance and durability for many other types of fuel cell systems.

Effects of Reaction Conditions on Cobalt-Catalyzed Fischer-Tropsch Synthesis: Interactions between Operating Factors

  • Ajamein, Hossein;Sarkari, Majid;Fazlollahi, Farhad;Atashi, Hossein
    • 대한화학회지
    • /
    • 제55권5호
    • /
    • pp.824-829
    • /
    • 2011
  • In Fischer-Tropsch Synthesis, because of few reactants ($H_2$, CO), scarce operating parameters affected on efficiency especially the selectivity of products. In this research, effect of operating parameters on the selectivity of Co-Mn-$TiO_2$ Fischer-Tropsch synthesis catalyst were studied by design of experimental procedure and Taguchi method. According to this research, interactions between operating factors have a crucial effect on light products selectivity. Among these interactions, (temperature${\times}$feed ratio) has the main influence on light hydrocarbons selectivity. It was concluded that temperature and feed ratio ($H_2$/CO) were the most integral operating parameters for much greater selectivity of light hydrocarbons.

Temperature Control using Peltier Element by PWM Method

  • Pang, Du-Yeol;Jeon, Won-Suk;Choi, Kwang-Hoon;Kwon, Tae-Kyu;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1400-1404
    • /
    • 2005
  • This paper presents the temperature control of aluminum plate by using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is charged to Peltier element, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with current control and operating cooling fan only while cooling duration. Operating cooling fan only while cooling duration is proper to get more rapid heating and cooling duration. As a result of experiment, it takes about 100sec period to repeating temperature between $35^{\circ}C$ and $70^{\circ}C$ and about 80sec from $40^{\circ}C$ to $70^{\circ}C$ in ambient air temperature $25^{\circ}C$ and while operating cooling fan only in cooling duration. Future aim is to apply this temperature control method in actuating SMHA(special metal hydride actuator) which is applicable in Siver project acting in low frequency range by using Peltier element for heating and cooling.

  • PDF

열전소자 온도조절법을 이용한 결정형 실리콘 태양전지의 성능 측정 (Performance of Crystalline Si Solar Cells with Temperature Controlled by a Thermoelectric Module)

  • 허기무;이대호;이재헌
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.375-379
    • /
    • 2015
  • A proper estimate of solar cell efficiency is of great importance for the feasibility analysis of solar cell power plant development. Since solar cell efficiency depends on temperature, several methods have been introduced to measure it by operating temperature modulation. However, the methods either rely on the external environment or need expensive equipment. In this paper, a thermoelectric module was used to control the operating temperature of crystalline silicon solar cells effectively and precisely over a wide range. The output characteristics of crystalline silicon solar cells in response to operating temperatures from $-5^{\circ}C$ to $100^{\circ}C$ were investigated experimentally. Their efficiencies decreased as the temperature rose, since the decrease in the open circuit voltage and fill factor exceeded the increase in the short circuit current. The maximum power temperature coefficient of the single crystalline solar cell was more sensitive to temperature change than that of the polycrystalline solar cell.