• 제목/요약/키워드: operating room

검색결과 762건 처리시간 0.028초

Anesthetic management during whole-lung lavage using lung ultrasound in a patient with pulmonary alveolar proteinosis: a case report

  • Jung, Jae Wan;Lee, Hyunho;Oh, Jimi
    • Journal of Yeungnam Medical Science
    • /
    • 제38권4호
    • /
    • pp.374-380
    • /
    • 2021
  • Pulmonary alveolar proteinosis (PAP) is an uncommon disease characterized by progressive accumulation of lipoprotein material in the lungs due to impaired surfactant clearance. Whole-lung lavage (WLL) is the current standard treatment and consists of sequential lavage of each lung to mechanically remove the residual material from the alveoli. Although WLL is considered safe, unexpected complications can occur. Moreover, due to the rarity of the disease itself, this procedure is unknown to many physicians, and management of intraoperative complications can be challenging for anesthesiologists. Lung ultrasound (LUS) provides reliable and valuable information for detecting perioperative pulmonary complications and, in particular, quantitation of lung water content. There have been reports on monitoring the different stages of controlled deaeration of the non-ventilated lung during WLL using LUS. However, it has been limited to non-ventilated lungs. Therefore, we report the use of LUS in WLL to proactively detect pulmonary edema in the ventilated lung and implement a safe and effective anesthesia strategy. Given the limited diagnostic tools available to anesthesiologists in the operating room, LUS is a reliable, fast, and noninvasive method for identifying perioperative pulmonary complications in patients with PAP undergoing WLL.

금속 산화물 가스 센서의 광 활성화 센싱 메커니즘 (Light-activated mechanism for metal oxide gas sensors)

  • 엄완식;신가윤;유동재;강석우;김은비;김현우
    • 센서학회지
    • /
    • 제30권6호
    • /
    • pp.381-383
    • /
    • 2021
  • Light-activated metal oxide gas sensors have been investigated in recent decades. Light illumination enhances the sensing attributes, including the operational temperature, sensitivity, and selectivity. Unfortunately, high operating temperature is a major problem for gas sensors because of the huge energy consumption. Therefore, the importance of light-activated room-temperature sensing has increased. This paper reviews recent light-activated sensors and their sensing mechanisms with a specific focus on metal oxide gas sensors. Studies use the outstanding ZnO and SnO2 sensors to research photoactivation when illuminated by various sources such as ultraviolet (UV), halogen lamp, or monochromatic light. Photon induction generates electron-hole pairs that increase the number of adsorption sites of gas molecules and ions improving the sensor's sensing properties.

간호·간병통합서비스 제공 병동의 운영현황 비교연구 (A Comparative Study on the Operation Status of Comprehensive Nursing Care Ward)

  • 이경아;이선희
    • 근관절건강학회지
    • /
    • 제25권3호
    • /
    • pp.196-204
    • /
    • 2018
  • Purpose: The purpose of this study was to contribute to the activation of comprehensive nursing care services by comparing and analyzing the working environment and operational status of comprehensive nursing care wards with general wards. Methods: A questionnaire survey was conducted at hospitals operating comprehensive nursing care services. We collected data on patient characteristics, workforce, working environment, and work support facilities of 40 hospitals voluntarily participating in the survey. The collected data were analyzed by dividing it into an comprehensive nursing care ward and a general ward. Results: Compared with the general ward, the comprehensive nursing care ward had fewer hospitalized patients, but the severity of the patients and the need for nursing were high. The number of nurses, assistant nurses, and ward support workers per patient was higher in the comprehensive nursing care ward than in the general ward, and the implementation rate of night shift fixed system, the fixed shift system, and the preceptor system were higher. In terms of structural environment, comprehensive nursing care wards had more room for interviews. Conclusion: The comprehensive nursing care ward had more nursing staff and provided a better working environment than the general ward, but required additional support for the structural environment.

대형 지진하중에 대한 시편의 변형률기반 손상평가 (Strain-based Damage Evaluation of Specimens under Large Seismic Loads)

  • 권형도;허은주;이종민;김진원
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.24-31
    • /
    • 2018
  • In this paper, specimen tests with simulated large seismic conditions have been carried out to investigate damage characteristics such as structural deformation and crack initiation under seismic loading. The mechanical behavior of the specimens is predicted by numerical simulations and the strain-based damage evaluations are performed. Finite element analyses of the specimens under the simulated seismic loading at room and operating temperatures were carried out for low alloy steel and stainless steel materials. Peak strain amplitude, cumulative fatigue damage and cumulative strain limit damage are calculated considering the nature of cyclic loading. In all cases, the allowable damage criteria are exceeded at the time of observing cracks visually in the tests. Therefore, it is confirmed that the material behavior due to the large seismic loads can be predicted by the numerical method and the structural damage of the materials can be evaluated conservatively based on the strain criteria.

Implications of 3-Dimensional Printed Spinal Implants on the Outcomes in Spine Surgery

  • Fiani, Brian;Newhouse, Alexander;Cathel, Alessandra;Sarhadi, Kasra;Soula, Marisol
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.495-504
    • /
    • 2021
  • Three-dimensional printing (3DP) applications possess substantial versatility within surgical applications, such as complex reconstructive surgeries and for the use of surgical resection guides. The capability of constructing an implant from a series of radiographic images to provide personalized anatomical fit is what makes 3D printed implants most appealing to surgeons. Our objective is to describe the process of integration of 3DP implants into the operating room for spinal surgery, summarize the outcomes of using 3DP implants in spinal surgery, and discuss the limitations and safety concerns during pre-operative consideration. 3DP allows for customized, light weight, and geometrically complex functional implants in spinal surgery in cases of decompression, tumor, and fusion. However, there are limitations such as the cost of the technology which is prohibitive to many hospitals. The novelty of this approach implies that the quantity of longitudinal studies is limited and our understanding of how the human body responds long term to these implants is still unclear. Although it has given surgeons the ability to improve outcomes, surgical strategies, and patient recovery, there is a need for prospective studies to follow the safety and efficacy of the usage of 3D printed implants in spine surgery.

Device modelling and performance analysis of two-dimensional AlSi3 ballistic nanotransistor

  • Chuan, M.W.;Wong, K.L.;Hamzah, A.;Rusli, S.;Alias, N.E.;Lim, C.S.;Tan, M.L.P.
    • Advances in nano research
    • /
    • 제10권1호
    • /
    • pp.91-99
    • /
    • 2021
  • Silicene is an emerging two-dimensional (2D) semiconductor material which has been envisaged to be compatible with conventional silicon technology. This paper presents a theoretical study of uniformly doped silicene with aluminium (AlSi3) Field-Effect Transistor (FET) along with the benchmark of device performance metrics with other 2D materials. The simulations are carried out by employing nearest neighbour tight-binding approach and top-of-the-barrier ballistic nanotransistor model. Further investigations on the effects of the operating temperature and oxide thickness to the device performance metrics of AlSi3 FET are also discussed. The simulation results demonstrate that the proposed AlSi3 FET can achieve on-to-off current ratio up to the order of seven and subthreshold swing of 67.6 mV/dec within the ballistic performance limit at room temperature. The simulation results of AlSi3 FET are benchmarked with FETs based on other competitive 2D materials such as silicene, graphene, phosphorene and molybdenum disulphide.

Concept of an intelligent operator support system for initial emergency responses in nuclear power plants

  • Kang, Jung Sung;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2453-2466
    • /
    • 2022
  • Nuclear power plant operators in the main control room are exposed to stressful conditions in emergency situations as immediate and appropriate mitigations are required. While emergency operating procedures (EOPs) provide operators with the appropriate tasks and diagnostic guidelines, EOPs have static properties that make it difficult to reflect the dynamic changes of the plant. Due to this static nature, operator workloads increase because unrelated information must be screened out and numerous displays must be checked to obtain the plant status. Generally, excessive workloads should be reduced because they can lead to human errors that may adversely affect nuclear power plant safety. This paper presents a framework for an operator support system that can substitute the initial responses of the EOPs, or in other words the immediate actions and diagnostic procedures, in the early stages of an emergency. The system assists operators in emergency operations as follows: performing the monitoring tasks in parallel, identifying current risk and latent risk causality, diagnosing the accident, and displaying all information intuitively with a master logic diagram. The risk causalities are analyzed with a functional modeling methodology called multilevel flow modeling. This system is expected to reduce workloads and the time for performing initial emergency response procedures.

Helium guard system design for HIAF iLinac cryogenic distribution system

  • Xianjin Wang;Shuping Chen;Wen Jun;Dajun Fan;Liming Zhu;Yanan Lib;Xiaofei Niu;Junhui Zhang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-10
    • /
    • 2023
  • 2 K superfluid helium cryogenic system is the crucial component of many large accelerators. When the cryogenic system is operating at 2K@3129Pa, many room-temperature parts are connected to superfluid helium via tubes. Air Leakage in these connections may lead to air contamination of the cryogenic system. Air contamination may cause equipment failure in cryogenic systems and, in extreme cases, render the entire accelerator system inoperable. Helium guard is a technique that guards against air contamination of these sub-atmospheric pressure connections in 2 K superfluid helium cryogenic system. This paper introduces a typical 2 K cryogenic distribution design for large accelerators, and make risk analysis of air contamination. Finally, the analysis of specific leakage points and detailed engineering design are presented, which may be used as a reference when designing of a 2 K superfluid helium cryogenic distribution system.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.

Diagnosis and Management of Sarcopenia after Hip Fracture Surgery: Current Concept Review

  • Jun-Il Yoo;Jung-Taek Kim;Chan Ho Park;Yonghan Cha
    • Hip & pelvis
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2022
  • To date, family medicine and internal medicine fields have been responsible for defining, researching, and development of treatments for sarcopenia, focusing mainly on diabetes and metabolic diseases. Therefore, application of current guidelines for diagnosis of sarcopenia which differ according to continent to patients with hip fractures in the orthopedic field is difficult. The purpose of this review was to understand the recent consensus on the definition and diagnosis of sarcopenia and to highlight the importance of research and future research opportunities on the management of sarcopenia in patients with hip fractures by orthopedic surgeons. The global prevalence of sarcopenia in patients with hip fractures is statistically significant. Despite establishment of various therapeutic and diagnostic criteria for osteoporosis in the clinical field, there are no clear, useful diagnostic criteria for sarcopenia in the clinical field. In particular, few studies on the evaluation and treatment of sarcopenia in patients with hip fractures have been reported. In addition, the quality of life of postoperative patients with hip fractures could be significantly improved by development of precise assessment for muscle regeneration and rehabilitation in the operating room.