• Title/Summary/Keyword: operating margin

Search Result 298, Processing Time 0.028 seconds

Thermal Margin Analysis of the Korea Nuclear Unit 1 Reactor Core Consisting of Standard or Optimized Fuel Assemblies (표준 핵연료집합체 또는 최적 핵연료집합체가 장전된 원자력 1호기 원자로심의 열적여유도 분석)

  • Hyun Koon Kim;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.155-160
    • /
    • 1984
  • Analyzed is the thermal margin of the Korea Nuclear Unit 1 (KNU-1) reactor core consisting of either 14 x 14 standard fuel assemblies (SFA) or optimized fuel assemblies (OFA). Employed for the analysis are two different thermal design methods; traditional and statistical thermal design method. Compared to the traditional design thermal method, the statistical thermal design method improves the core thermal margin utilizing best-estimate values for the core operating parameters combining their uncertainties in a statistical manner. Calculations are performed using a steady state and transient thermal-hydraulic analysis computer program, COBRA-IV-i. Calculated results show that the statistical thermal design method significantly improves the thermal margin and satisfies the core thermal design base of the KNU-1 SFA and OFA core. However, the thermal design base can not be met, if the traditional thermal design method is employed for the OFA role analysis.

  • PDF

Simulation and Layout of Single Flux Quantum AND gate (단자속 양자 AND gate의 시뮬레이션과 Layout)

  • 정구락;박종혁;임해용;강준희;한택상
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.141-143
    • /
    • 2002
  • We have simulated and Laid out a Single Flux Quantum(SFQ) AND gate for Arithmetic Logic Unit by using XIC, WRspice and Lmeter. This circuit is a combination of two D Flip-Flop. D Flip- Flop and dc SQUID are the similar shape from the fact that it has the a loop inductor and two Josephson junction. We also obtained operating margins and accomplished layout of the AND gate. We got the margin of $\pm$42% over.

  • PDF

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Factors Affecting the Performance of Local Public Hospitals (지방의료원의 경영성과에 미치는 영향)

  • Yang, Jong-Hyun;Lee, Jung-Woo
    • The Korean Journal of Health Service Management
    • /
    • v.11 no.3
    • /
    • pp.1-11
    • /
    • 2017
  • Objectives : The purpose of this study was to analyze factors affecting the performance of public hospitals in South Korea. Methods : We collected management performance data from 2013 to 2015 from income statements, balance sheets, and annual reports from 32 local public hospitals. The dependent variable used was profitability, which included operating margin, return on assets and net profit to gross revenues. The independent variables were general characteristics, liquidity, stability, and activity. Results : Patient revenues, total assets, and total capital had increased steadily but patient expenses had increased to a greater extent. Operating profit, and net profit were consistently in deficits and the management status of local public hospitals had recently been in difficulty. The debt ratio, quick ratio, ratio of fixed liability and fixed assets turnover rate have a significant positive(+) effect on performance in the years 2013-2015. Conclusions : We suggest management strategies for these hospitals based on the results analyzed.

A Comparative Analysis of Business Performance of University Hospitals for the Past 10 Years (최근 10년간 대학병원 경영성과 비교분석)

  • Yang, Jong-Hyun
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.13-25
    • /
    • 2016
  • Objectives : The purposes of this study was to analyze business performance of university hospitals for the past 10 years. Methods : Management and finance data from 2005 to 2014 were collected from balance sheets, income statements and annual reports from 27 university hospitals. The dependant variable used was profitability which included return on assets, operating margin and net profit to gross revenues 1. The independent variables were general characteristics, liquidity, stability, activity and financial ratios. Results : University hospitals over the last 10 years had achieved good management performance. Using financial leverage, patient revenues, operating profit, nonpatient revenues, total assets and total debt, the total amount had increased by more than double. The ratio of fixed liability and fixed assets turnover was found to have a significant positive (+) effect on management performance in the years 2012-2014. Conclusions : Based on these results, this study suggests a more in-depth analysis using fixed liabilities and fixed assets.

Source Side Power Factor Correction for Utility Interactive Photovoltaic System (계통연계형 태양광 발전 시스템에서의 전원측 역율 개선)

  • 조영준;김홍성;목형수;최규하;김한성
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.386-392
    • /
    • 1997
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reserve margin in summer. As one of the remedies about this problem, the small scale utility interactive photovoltaic system(UIPVS) is considered for auxiliary power source. For this system one of problems to be solved technically, system operating power factor. Generally in case of small scale system, system is operated in unity power factor. But this unity power factor operating mode decrease power factor viewed from utility because UIPVS supply active power to utility. Therefore this paper propose UIPVS with power factor correcting function and this system is analyzed.

  • PDF

Design of MYNAMIC CMOS ARRAY LOGIC (DYNAMIC CMOS ARRAY LOGIC의 설계)

  • 한석붕;임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.10
    • /
    • pp.1606-1616
    • /
    • 1989
  • In this paper, the design of DYNAMIC CMOS ARRAY LOGIC which has both advantages of dynamic CMOS and array logic circuits is proposed. The major components of DYNAMIC CMOS ARRAY LOGIC are two-stage dunamic CMOS circuits and an internal clock generator. The function block of dynamic CMOS circuits is realized as a parallel interconnection of NMOS transistors. Therefore the operating speed of DYNAMIC CMOS ARRAY LOGIC is much faster than the one of the conventional dynamic CMOS PLAs and static CMOS PLA. Also, the charge redistribution problem by internl delay is solved. The internal clock generator generates four internal clocks that drive all the dynamic CMOS circuits. During evaluation, two clocks of them are delayed as compared with others. Therefore the race problem is completoly eliminated. The internal clock generator also prevents the reduction of circuit output voltage and noise margin due to leakage current and charge coupling without any penalty in circuit operating speed or chip area utilization.

  • PDF

Analysis Stability of Cable-In-Conduit-Conductor with NbTi Superconducting Strands of Various Cu/SC Ratios Used in PF6 of KSTAR

  • Qiuliang Wang;Kim, Myungkyu;Yoon, Cheon-Seong;Lee, Sangil;Kim, Keeman
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.53-56
    • /
    • 2001
  • The stability of PF 6-7 has been studied according to the transient analysis code TOKSCPF and quench analysis code QSAIT. We compare the stability and temperature rise with various Cu/SC ratios of 2.8 and 3.5 under the KSTAR normal operating conditions. It shows that the Cu/SC ratio has an influence on the quench propagation and stability margin. In transient operating condition, the Cu/SC ratio weakly influences on the temperature rise in PF magnet.

  • PDF

Areal Selective 2-bit Dimming of Mercury-free Flat Fluorescent Lamp for LCD Backlight

  • Jung, Jae-Chul;Lee, Ju-Kwang;Seo, In-Woo;Oh, Byung-Joo;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1729-1732
    • /
    • 2006
  • We proposed a new Mercury-free Flat Fluorescent Lamp (MFFL) for LCD backlight which shows a wide, stable operating voltage margin, high luminance and efficiency. In this paper, we expanded the single cell with 4 inch diagonal size into the multi-cell for the large size LCD-TV backlight application, examined its operating characteristics and proposed a driving scheme for 2-bit areal selective dimming control.

  • PDF

Numerical Optimization of a Transonic Axial Compressor with Casing Grooves for Improvement of Operating Stability (케이싱 그루브가 장착된 천음속 축류압축기의 작동 안정성 향상을 위한 수치최적화)

  • Kim, Jin-Hyuk;Choi, Kwang-Jin;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.31-38
    • /
    • 2011
  • Optimization using a hybrid multi-objective evolutionary algorithm coupled with response surface approximation has been performed to improve the performance of a transonic axial compressor with circumferential casing grooves. In order to optimize the operating stability and peak adiabatic efficiency of the compressor with circumferential casing grooves, tip clearance, angle distribution at blade tip and the depth of the circumferential casing grooves are selected as design variables. Three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model are discretized by finite volume approximations. The trade-off between two objectives with the interaction of blade and casing treatment is determined and discussed with respect to the representative clusters in the Pareto-optimal solutions compared to the axial compressor without the casing treatment.