• Title/Summary/Keyword: opening a door

Search Result 187, Processing Time 0.026 seconds

Effects of Initial Condition and Opening Geometry of a Compartment on the Gravity Current in the Backdraft (백드래프트의 중력흐름에 미치는 구획실 내부 초기조건 및 개구부 형상의 영향)

  • Park, Ji-Woong;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.18-25
    • /
    • 2015
  • Computational study of a gravity current prior to the backdraft was conducted using fire dynamic simulator (FDS). Various initial conditions of mixture compositions and compartment temperature as well as four opening geometries (Horizontal, Door, Vertical, and Full opening) were considered to figure out their effects on the gravity current. The density difference ratio (${\beta}$) between inside and outside of compartment, the gravity current time ($t_{grav}$) and velocity ($v_{grav}$), and non-dimensional velocity ($v^*$) were introduced to quantify the flow characteristics of the gravity current. Overall fluid structure of the gravity current at the fixed opening geometry showed similar development process for different ${\beta}$ conditions. However, $t_{grav}$ for entering air to reach the opposed wall to the opening geometry increased with ${\beta}$. Door, Vertical, and Horizontal openings where openings are attached on the ground showed similar development process of the gravity current except for Horizontal opening, which located on the middle of the opening wall. The magnitude of $v_{grav}$ at fixed ${\beta}$ was, from largest to smallest, Full > Vertical > Door > Horizontal, but it depended on both the size and location of the opening. On the other hand, $v^*$ was found to be independent to ${\beta}$, and only depended on the geometry of the opening.

Verifying the Suitability or Unsuitability of the Opening Force Criteria Applied to Air Pressurized Access Door to a Smoke Control Zone (급기 가압 제연구역 출입문에 적용되는 개방력 기준의 적합성 여부에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5820-5825
    • /
    • 2014
  • The aim of this study was to verify the suitability or unsuitability of Korean body types by measuring the opening force criteria of an air pressurized access door to a smoke control zone. The opening force criteria were verified by comparing the NFSC 501A, NFPA 92A and BS-EN 12101-6 based on the body standards information from the Korean Agency for Technology and Standards. When measuring the opening forces, the posture of the body should be standing upright and pushing an access door with the right hand, which is a criterion for designing doors. As a result of analyzing the actual measurement results, the pushing force of men and women in their 30's was the maximum value and the forces in those in their 60's was the minimum value. In addition, the deviations in the pushing forces varied considerably. As a result of comparing the NFSC 501A, the men showed lower values than the criteria in every gender and age variable except for the 20's, 30's and 50's variable. A comparison of the criteria of NFPA 92A showed that the mean of the measured values from every gender and age was also lower than the criteria. In addition, when comparing the criteria of BS-EN 12101-6, it was found that the men in every age variable were higher than the criteria. On the other hand, the women in every age variable were lower than the criteria. Therefore, considering the Korean body type against the Western body type, it was decided that the opening force of an access door to a smoke control area to make a downward adjustment should be 110 N in the local criteria. Furthermore, the criteria should consider the characteristics of buildings and users because an optional application of the international standard is not necessarily suitable for local situations.

Analysis of Twisting Deformation and Structural Design of the Door Frame of a Microwave Oven to Decrease Leakage of Microwave (전자파 누설 저감을 위한 전자레인지 도어 프레임의 비틀림 변형 해석과 구조 설계)

  • Lee, Boo-Youn;Koo, Jin-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.141-148
    • /
    • 2005
  • When one opens the door of a microwave oven during operation, microwave might leak through the clearance of the door. Present research has been motivated by the need to reduce the possible clearance by enhancing torsional stiffness of the door of the microwave oven. Static deformation of the door frame of the oven is analyzed under a door-opening force. On the basis of the topological optimization, the right flange of the door frame is shown to need reinforcing. Several types of reinforcing brackets weldable to the right flange is proposed, and their effects to the stiffness of the door frame are compared and evaluated.

Analysis of Differences in Indoor Environment and Fatigue Response According to Ventilation in Lecture Hall (대형강의실의 환기여부에 따른 실내환경과 피로감 반응의 차이분석)

  • Oh, Ye-Seul;Hwang, Jin-A;Choi, Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.2
    • /
    • pp.417-428
    • /
    • 2010
  • The purpose of this study was to analyze differences of the indoor environment and student's fatigue response according to ventilation in university lecture hall. The experiments consisted of measuring the indoor environmental parameters and a survey of student's responses. The experiments were in the lecture hall that the actual lecture was conducted in on the $25^{th}$ of May 2009 (not opening windows and door- A) and the $1^{st}$ of June 2009 (opening windows and door- B). The experimental variable was ventilation by opening the windows and door, and the controlled conditions were indoor temperature by air conditioner, volume of the microphone and VTR, lighting conditions and teaching method. The results are as follows: 1) The indoor temperature was maintained in controlling A, B but the $CO_2$ and relative humidity of A (average 3579ppm, 62.6%) was higher than B (average 1697ppm, 48.1%). 2) There were differences in the student's subjective responses and student's fatigue responses between A and B. 3) Therefore, it was found that ventilation by opening the windows and door was a valid way to improve the relative humidity and to reduce $CO_2$ in the lecture hall.

Magnetocardiography System in Open-door Magnetically-shielded Room (열린 자기차폐실의 심자도 시스템)

  • Kim, J.M.;Lee, Y.H.;Kwon, H.;Yu, K.K.;Kim, K.;Park, Y.K.;Sasada, Ichiro
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 2007
  • We have installed a 61-channel magnetocardiography (MCG) system inside a magnetically shielded room (MSR) with a size of $2.4\;m\;{\times}2.4\;m\;{\times}2.4\;m$. The MCG system consists of 1st-order axial gradiometers containing double relaxation oscillation SQUIDs (DROSs) with pick-up coils of a base line of 70 mm. The MSR holds a shielding factor of 50 at 0.1 Hz and 10000 at 100 Hz, when its door in the middle on a front wall is closed. On opening the MSR door, we have obtained the characteristics of the MCG system with a 2.9 Hz noise generated from an air conditioning unit at 13 m distance off the MSR. In an open-door MSR ($140^{\circ}$ opening), a noise at the center channel increases up to $700\;fT/Hz^{l/2}$ at 2.9 Hz and $1.7\;pT/Hz^{1/2}$ at 60 Hz. MCG signals for a healthy human do not show distortion until the door opens to $45^{\circ}$, but show the effect of noise when the door opens further at $90^{\circ}$ and $140^{\circ}$. With the door opens to $45^{\circ}$, MCG measurement can be performed with ease of door operation and without creating claustrophobia for the patient.

  • PDF

Dynamical Mechanism Analysis of An Industrial Two-step Folding Automatic Door (2단 접이식 산업용 자동문의 동역학적 메카니즘 해석)

  • Yun, Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.821-826
    • /
    • 2011
  • This paper deals with an analysis of dynamic mechanism for the industrial two-step folding automatic door. A nonlinear equation of motion was derived in terms of folding angle to estimate driving forces. Based on this dynamic behavior, time taken during the door's opening well as their velocities were controlled so that the operating conditions can be obtained for the purpose of design. The stiffness of twisting spring was also investigated when the automatic door closed, because a dangerous accident takes place from the door's free falling. The current research will be a very useful tool in the near future for the dynamic analysis for the multi-step folding automatic door.

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.

Evaluation of Twisting Deformation of the Door Frame of a Microwave Oven by Transient Response Analysis (과도응답 해석에 의한 전자레인지 도어 프레임의 비틀림 변형 평가)

  • Koo, Jin-Young;Lee, Boo-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1282-1288
    • /
    • 2005
  • This research has been motivated by the need to minimize possible leakage of microwave when one opens the door during operation of the microwave oven. An explicit finite element program is used to analyze the transient response the door of the oven under door-opening condition. Operation of the micro switch which plays an important role to hun off the power is simulated on the basis of the response of the latch. Using the results of the analysis, twisting deformation of the door frame is defined and evaluated.

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF