Abstract
The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.
Keywords
Exit light pictogram; Directionality; Evacuation route;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Nation Fire Agency, "Standards of Model Approval and Inspection Technology for EXIT LIGHT", No 2018-3, (2018).
2 A. R. Hong, "A Study for Evacuation Performance Improvement of Emergency Exit Light Pictogram", Master's Thesis, Gachon University (2016).
3 J. W. Choi, "A Study for Evacuation Performance Improvement of Emergency Exit Light Pictogram", Master's Thesis, University of Seoul (2013).
4 C. B. Kim, M. Y. Hur, Y. K. Oh, J. H. Choi and J. J. Jung, "The Effect of the Running-man Emergency Exit Sign and Its Installed Location on Human Directional Choice", Korea Jounal of Psychology : General, Vol. 35, No. 1, pp. 1-12 (2016).   DOI
5 C. B. Kim, H. Y. Seo, M. Y. Hur, Y. J. Lee, Y. K. Oh and J, H, Choi, "The Spatial Stroop Effect Between the Direction and Installed Location of the Emergency Evacuation Route Sign", Appl. Cognit. Psychol. 30, pp. 1014-1019 (2016).   DOI
6 M. G. Seo, "Affordance Assessment Depending on Design Condition of Exit Signage and Opening Direction of an Exit oor", Master's Thesis, Pukyong National University (2017).
7 W. H. Hong and K. Y. Jeon, "The Study about the Behavior Patterns of Survivors and the Application of Them for Designing the Escape Route at the Subway Fire in Daegu", Proceedings of 2003 Spring Annual Conference, Korean Institute of Fire Science & Engineering, pp. 367-373 (2003).
8 W. H. Hong and K. Y. Jeon, "AA Study on Safe Egress Countermeasure in Underground Space Through the Analyzing Survivors' Exit Patterns of Daegu City Subway Arson", The Architectural Institute of Korea, Vol. 21, No. 1, pp. 235-242 (2005).