• Title/Summary/Keyword: on-site implementation

Search Result 495, Processing Time 0.029 seconds

Design and Implementation of Data Processing Middleware and Management System for IoT based Services

  • Lee, Yon-Sik;Mun, Young-Chae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Sensor application systems for remote monitoring and control are required, such as the establishment of databases and IoT service servers, to process data being transmitted and received through radio communication modules, controllers and gateways. This paper designs and implements database server, IoT service server, data processing middleware and IoT management system for IoT based services based on the controllers, communication modules and gateway middleware platform developed. For this, we firstly define the specification of the data packet and control code for the information classification of the sensor application system, and also design and implement the database as a separate server for data protection and efficient management. In addition, we design and implement the IoT management system so that functions such as status information verification, control and modification of operating environment information of remote sensor application systems are carried out. The implemented system can lead to efficient operation and reduced management costs of sensor application systems through site status analysis, setting operational information, and remote control and management.

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

A Study on the Utilization of QR Code for Improving the Effectiveness of Safety Education in Power Plant Workplaces (발전소 사업장의 안전교육 효과성 향상을 위한 QR Code 활용방안 연구)

  • Oh, Myeong-Geun;Kim, Young-Kook;Jeong, Kyung-Ok
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.33-39
    • /
    • 2022
  • In order to improve the implementation of safety and health education at the site for industrial accident prevention activities, research was conducted to minimize inconvenience and increase utilization by redesigning and developing existing education methods. To date, occupational safety and health education has been conducted without considering the general work characteristics and functional facilities (mechanical, electrical, instrumentation, chemical) of workers (mechanical: turbine, valve, pump, hydraulic system, electrical: generator, breaker, motor, etc.). In particular, plant facilities were classified as mechanical and electrical facilities to improve the methodology for industrial safety and health education for plant maintenance workers. In addition, the "One Page Education Plan" was announced as a learning case because the spread of COVID-19 infectious diseases made it impossible to reduce or control the number of people in all groups and groups. The improvement of this training method will play a major role in improving the effectiveness of safety education in power plant workplaces.

A Study on the Design and Real-Time Implementation of Robust Sensor Monitoring Device in Explosion Proof Industrial Site (방폭 산업 현장에 강인한 센서 모니터링 장치 설계 및 실시간 구현에 대한 연구)

  • Jeong-Hyun Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.867-874
    • /
    • 2023
  • In this paper, a wireless communication-based sensor data monitoring device with an explosion-proof (Exd IIC) case was implemented to enable installation at explosion-risk industrial sites such as plants. In existing industrial plant sites, most of the temperature sensors and vibration and impact sensors are wired up to several kilometers, which takes a lot of time and money to bury long pipes and cables. In addition, there are not many cases where some wireless devices have been applied to actual plant industry sites due to communication quality problems. Therefore, in order to solve this problem, zigbee mesh wireless communication was applied to provide high reliability wireless communication quality to industrial plant sites, and the time and cost incurred in new or additional installation of sensors could be greatly reduced. In particular, in the event of loss or error of some wireless communication devices, the communication network is automatically bypassed or recovered to enable real-time data monitoring.

6TALK : Implementation of NAT-PT/SIIT and enhanced ALG

  • 이주철;호용근;신명기;김형준
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.701-705
    • /
    • 2002
  • This paper describes implementation of IPv6-IPv4 transition toolbox named as 6TALK(IPv6 TrAansLator of Krv6) and some scenarios using 6TALK which enables IPv6 island to connect other IPv6 island or IPv4 island seamlessly. 6TALK implements some transition mechanisms suggested in NGTrans Working Group of IETF. Those mechanisms are composed of basic mechanism, tunneling, and applied mechanism such as DSTM. 6TALK provides functions which enable IPv6 network at the edge of existing network to communicate with IPv4 network by using these transition mechanisms. As major transition mechanisms in 6TALK we adopt NAT-PT/SIIT and DSTM/DSTM options and as implementation environment we use Linux Kernel 2.4.18 and Netfilter framework. Software modules implemented in Linux kernel was ported to hardware box using Motorola MPC 8260 processor. The transition mechanisms used in 6TALK are the ones predicted to be used in initial transition step to IPv6.

  • PDF

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.

The Design & Effect Analysis of Project Objective Management Information System for National R&D cooperated by Industries, Universities and Government-supported research institutes (국가 산.학.연 협력 연구개발을 위한 과제목표관리 정보시스템의 설계 및 효과 분석)

  • Sohn, Kwon-Joong;Yoo, Wang-Jin;Lee, Cheol-Gyu
    • Journal of Technology Innovation
    • /
    • v.16 no.1
    • /
    • pp.107-139
    • /
    • 2008
  • We studied how to achieve successful implementation of massive research and development projects requiring collaboration among industries, universities and government-supported research institute. We have set up an engineering process innovation model to be deemed most adequately for all practical purposes, relying on the theoretical studies on the merits and analysis of the effect of the information system based on Milestone Management, Work Breakdown Structures and Web, which is known to be effective for research project (schedule) management and the objective management, and implemented a real-world web-based project objective management system. After a review of various R & D Project Schedule Management methods, we found that this information system was very compatible with project objective management. This project objective management information system carries out research and development projects effectively and efficiently, getting together in cyber-space and sharing information, and has been equipped with an Early Warning Subsystem to allow for pre-analysis and timely response to potential problems arising from the course of the project. The system also contains an Executive Information System that in real time, automatically provides the management information required by managers with the rate of project progress (achievement, fulfillment and delay). Lastly, actual progress can be cross-checked through both on-line objective management on the web-based information system and design review meeting held on site, to improve the efficiency and validity of the information system. Moreover, overall effect was analyzed through questionnaires on how well the system and generated information meet requirements and on the ultimate impact of the system upon objective management and communication. The questionnaire on the system effect revealed that the information system was useful to objective management and communication, and that the quality of the system was more than acceptable as well.

  • PDF

A Pilot Study on Installation Criteria of Speed Change Lanes according to the Implementation of Safety Speed "5030" in the Urban Area (도심내 안전속도 "5030"시행에 따른 변속차로 설치기준에 관한 기초연구)

  • Oh, Seok-Jin;Ha, Tae-Jun;Jin, Tae-Hee;Shin, Kwang-Min;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • The speed change lane is installed at the point where the roads are connected on the urban roads, reducing the relative speed to facilitate traffic communication. However, in the case of the speed limit of 30 km/h in accordance with the implementation of the safe speed "5030" in the city, the standard is ambiguous, and there are criticisms about the installation of the transmission lane. This study conducted a pilot study on the traffic patterns of the speed change lanes, focusing on the section where the safe speed "5030" policy was scheduled to be implemented after theoretical consideration of the speed change lanes. After on-site investigation, as a result of analyzing the traffic pattern according to the travel speed of the main road according to road conditions and traffic conditions, the effectiveness of the speed change lane according to the safety speed "5030" was analyzed. In this study, the installation criteria for speed change lane by speed were presented. The criteria is that "speed change lanes should not be installed when the speed limit is 30 km/h, and speed change lanes should be installed when the speed limit is 50 km/h." The criteria will be considered as a reference when establishing engineering standards for connection of other facilities in urban areas in the future. It is expected that unnecessary restrictions on individuals' exercise of private property rights will be minimized, smooth traffic flow and secure safety by the installation of speed change lanes and expansion of turning radius.

Health Impact Assessment on Construction of Landfill Site - Focused on Human Risk Assessment due to Inhalation Exposure to Landfill Gas - (매립장 조성사업에 대한 건강영향평가 - 매립가스의 호흡노출로 인한 인체위해성평가를 중심으로 -)

  • Kim, Young-Ha;Lee, Young-Soo
    • Journal of Environmental Policy
    • /
    • v.7 no.1
    • /
    • pp.1-29
    • /
    • 2008
  • The Ministry of Environment(MoE) of Korea has recently established the Environmental Health Act. This Act contains a clause related to implementation of Health Impact Assessment(HIA). So, selecting a landfill which was expected to have an influence on human health among major development projects, this study carried out the human risk assessment due to inhalation exposure to landfill gas emission and attempted to measure the possibility of domestic application of HIA in the future. The process for HIA on landfill site extension focusing on human risk assessment is as follows: The first step is to presume and calculate the amount of landfill gas emissions using LandGEM, The second step is to carry out exposure assessment using K-SCREEN Model which is used for predicting the concentration in a conservative method. The last step is to carry out human risk assessment of carcinogenic and non-carcinogenic substances. It is considered that it is likely to apply a technique for human risk assessment due to inhalation exposure to landfill gas emission performed here more specifically in the case of implementing HIA. In addition, it is also believed that more systematic studies are needed to overcome some weak points and limits found in this study and if these weak points and limits are improved more reliable outcomes will be produced.

  • PDF

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.