• Title/Summary/Keyword: on-off control

Search Result 2,536, Processing Time 0.028 seconds

Sensor Node Control Algorithm Based on TinyOS (TinyOS 기반의 센서 노드 제어 알고리즘)

  • Boo, Jun-Pil;Yang, Hyeon-Gyu;Kim, Do-Hyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, there is developing various ubiquitous application services using sensor networks based on TinyOS represented the operating system of sensor node. These sensor networks perform the collection and the transmission of sensing data from sensor node to get the context information. In this paper, we proposes the sensor node control algorithm which converts a sensor node to sleep, active, power off mode according to monitoring result of the voltage state of sensor node. Also, we designs and implement the sensor control module on server, sink, sensor node of sensor networks using this algorithm. It designs a sensor voltage control module of sensor node, data receive and display module of USN server using a java language and TinyOS. And, it checks the voltage state of sensor node, and it changes one of the sleep or power off modes in case of high voltage loss. Accordingly, we effectively use the power of sensor nodes as changing control modes of sensor nodes.

  • PDF

Movement Compatibility of ON/OFF Controls (ON/OFF 조정장치의 운동 양립성에 관한 연구)

  • Jeong, Byung-Yong;Lee, Jung-Uk
    • IE interfaces
    • /
    • v.14 no.3
    • /
    • pp.302-309
    • /
    • 2001
  • Direction-of-motion stereotypes between ON/OFF controls were tested using a paper-and-pencil test and interview method. One hundred and forty eight subjects of both genders and from a wide range of ages were asked to indicate the control movement they would make to turn on the light. Stereotypes were obtained for nine types of ON/OFF controls in two different planes. The results show that stereotype for left-right power switches is right for on, and stereotype for up-down switches is up. And, a strong stereotype was found in the case of left-right switches than up-down switches. Some stereotypes are significantly different between genders and age groups. These findings identified in this study can be used to design the ON/OFF switches of the facilities and equipments.

  • PDF

A Design of Dynamic Simulator of Articulated Robot (다관절 로봇의 동적 시뮬레이터 설계)

  • Park, In-Man;Jung, Seong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • This study proposes an articulated robot control system using an on/off-line robot graphic simulator with multiple networks. The proposed robot control system consists of a robot simulator using OpenGL, a robot controller based on a DSP(TMS320) motion board, and the server/client communication by multiple networks. Each client can control the real robot through a server and can compare the real robot motion with the virtual robot motion in the simulation. Also, all clients can check and analyze the robot motion simultaneously through the motion image and data of the real robot. In order to show the validity of the presented system, we present an experimental result for a 6-axis vertical articulated robot. The proposed robot control system is useful, especially, in the industrial fields using remote robot control as well as industrial production automation with many clients.

The Development of Intelligent Direct Load Control System

  • Choi, Sang Yule
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2015
  • The electric utility has the responsibility of reducing the impact of peaks on electricity demand and related costs. Therefore, they have introduced Direct Load Control System (DLCS) to automate the external control of shedding customer load that it controls. Since the number of customer load participating in the DLC program are keep increasing, DLCS operators a re facing difficulty in monitoring and controlling customer load. The existing DLCS needs constant operator intervention, e.g., whenever the load is about to exceed a predefined amount, it needs operator's intervention to control the on/off status of the load. Therefore, DLCS operators need the state-of-the-art DLCS, which can control automatically the on/off status of the customer load without intervention as much as possible. This paper presents an intelligent DLCS using the active database. The proposed DLCS is applying the active database to DLCS which can avoid operator's intervention as much as possible. To demonstrate the validity of the proposed system, variable production rules and intelligent demand controller are presented.

Anti-sway Control of Crane (기중기의 흔들림 방지제어)

  • Roh, Chi-Weon;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.977-979
    • /
    • 1996
  • This paper presents an algorithm to control the undesirable sway of a suspended load in the crane system that has a trade-off between positioning the load and suppressing the sway of the load. The aim is to transport the load to a specified place with small sway angle as quickly as possible. Dynamic model is based on a simple pendulum driven by a velocity drive that is mostly used for actuating a trolley in industry. Proposed algorithm is composed of two parts : one is a off-line optimal trajectory generator, the other on-line tracking control. The former produces optimal trajectories minimizing energy under the speed constraint of velocity drive. The latter controls outputs to track the generated trajectories. Digital simulations and experiments are performed on a pilot crane to demonstrate the performance of the proposed control algorithm.

  • PDF

Study on User Interface for a Capacitive-Sensor Based Smart Device

  • Jung, Sun-IL;Kim, Young-Chul
    • Smart Media Journal
    • /
    • v.8 no.3
    • /
    • pp.47-52
    • /
    • 2019
  • In this paper, we designed HW / SW interfaces for processing the signals of capacitive sensors like Electric Potential Sensor (EPS) to detect the surrounding electric field disturbance as feature signals in motion recognition systems. We implemented a smart light control system with those interfaces. In the system, the on/off switch and brightness adjustment are controlled by hand gestures using the designed and fabricated interface circuits. PWM (Pulse Width Modulation) signals of the controller with a driver IC are used to drive the LED and to control the brightness and on/off operation. Using the hand-gesture signals obtained through EPS sensors and the interface HW/SW, we can not only construct a gesture instructing system but also accomplish the faster recognition speed by developing dedicated interface hardware including control circuitry. Finally, using the proposed hand-gesture recognition and signal processing methods, the light control module was also designed and implemented. The experimental result shows that the smart light control system can control the LED module properly by accurate motion detection and gesture classification.

Energy Saving System of EHP Control at the College Lecture Room (대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템)

  • Jeong, Kybum
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 2014
  • Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

Temperature control of a batch PS polymerization reactor using on-line two-step method (온라인 2단계 방법을 이용한 회분식 PS 중합반응기의 온도제어)

  • 이병모;노형준;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.305-308
    • /
    • 1997
  • The on-line calculation method is developed to obtain the temperature trajectory that brings the reactants to the desired state in batch styrene polymerization reactor. The temperature trajectory is obtained by applying the moments of the polymer concentration to the 2-step calculation method. The computer simulation is also carried out to verify the superiority of the on-line method to the off-line one. When a temperature disturbance of constant size is introduced, the off-line results shows considerable deviation from the target degree of polymerization. The on-line strategy set up a new trajectory to reach the desired state by using the current state of the reactor. Therefore, the on-line strategy deals with the changes of the system more adequately than the off-line strategy.

  • PDF

Study on a Program for Automatic Control of on/off Switch on Modem (MODEM의 자동제어기 & 프로그램에 관한 연구)

  • Han Sang-Do
    • Journal of the military operations research society of Korea
    • /
    • v.17 no.2
    • /
    • pp.123-134
    • /
    • 1991
  • one of the problems the users of DPS-6/45 used to face in the course of having access to work stations was that a telephone call has to be made manually every time to have receiver's modem on or off, and naturally it meant the waste of manpower as well as of time. A program has been worked out to automatically operate and control. utilizing the system clock within the main computer (DPS-6/45), the on/off switch on the modems. It has resulted in; 1) promotion in operability of the main computer, DPS-6/45 2) prevention of unnecessary telephone calls 3) curtailment of expenditure and manpower

  • PDF

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.