• Title/Summary/Keyword: on-device

Search Result 19,531, Processing Time 0.051 seconds

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

  • Avinash Mani;Sivadasanpillai Harikrishnan;Bijulal Sasidharan;Sanjay Ganapathi;Ajit Kumar Valaparambil
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.180-187
    • /
    • 2023
  • BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.

Development of Complex Energy Saving Device

  • Lee, Kwi-Joo;An, Jung-Sun
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.1-5
    • /
    • 2012
  • A complex energy saving device has been developed for middle class vessels. The propulsive performance of the developed device is described through a model test. The pre-swirl stator, which recovers the rotational energy of the propeller slipstream, is a well-known energy saving device for large vessels. The pre-swirl stator for a large vessel is usually cast as a part of the stern frame and has a high cost. The manufacture of a cast stator for an existing vessel is almost impossible. The complex device that was developed can be fitted on astern frame by welding. The model tests show a 4-6% efficiency gain for middle class vessels with the developed appendages compared to those with bare hulls.

Development of New LTPS Process

  • Yi, Chung;Park, Kyung-Min;Choi, Pil-Mo;Kim, Ung-Sik;Kim, Dong-Byum;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1024-1026
    • /
    • 2004
  • We have developed the five mask $PMOS^1$ and the six mask CMOS process architecture for poly-Si TFT. In order to have a competitive process with that for a-Si TFT, the simple co-planar electrode structure whose data line electrode and pixel electrode are on the same plane was adopted. In addition, RGB + White four color $technology^2$ were applied to achieve high aperture ratio and transmittance. Using the aforementioned process architecture and four color technology, 2.0 inch qCIF transmissive micro-reflectance (TMR) device was successfully fabricated.

  • PDF

A Study on the Enhancement of Emission Efficiency of an Organic EL Devices Using the RF Plasma (RF 플라즈마를 이용한 유기 EL소자의 발광 효율에 관한 연구)

  • 박상무;김형권;신백균;임경범;이덕출
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.400-406
    • /
    • 2003
  • Efficient electrodes are devised for organic luminescent device(OLED). ITO electrode is treated with $O_2$ plasma. In order to inject hole efficiently, there is proposed the shape of anode that inserted plasma polymerized films as buffer layer between anode and organic layer using thiophene monomer. In the case of device inserted the buffer layer by using the plasma polymerization after $O_2$ plasma processing for ITO transparent electrode, since it forms the stable interface and reduce the moving speed of hole, the recombination of hole and electronic are made in the emitting layer. Therefore it realized the device capability of two times in the aspect of luminous efficiency than the device which do not be inserted the buffer layer. Experiments are limited to the device that has the structure of TPD/$AIq_3$, however, the aforementioned electrodes can similarly applied to the organic luminous device and the Polymer luminous device.

A Study on Characteristics of Wet Gate Oxide and Nitride Oxide(NO) Device (Wet 게이트 산화막과 Nitride 산화막 소자의 특성에 관한 연구)

  • 이용희;최영규;류기한;이천희
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.970-973
    • /
    • 1999
  • When the size of the device is decreased, the hot carrier degradation presents a severe problem for long-term device reliability. In this paper we fabricated & tested the 0.26${\mu}{\textrm}{m}$ NMOSFET with wet gate oxide and nitride oxide gate to compare that the characteristics of hot carrier effect, charge to breakdown, transistor Id_Vg curve and charge trapping using the Hp4145 device tester As a result we find that the characteristics of nitride oxide gate device better than wet gate oxide device, especially a hot carrier lifetime(nitride oxide gate device satisfied 30years, but the lifetime of wet gate oxide was only 0.1year), variation of Vg, charge to breakdown and charge trapping etc.

  • PDF

A Study on the Design and Electrical Characteristics of High Performance Smart Power Device (고성능 Smart Power 소자 설계 및 전기적 특성에 관한 연구)

  • Ku, Yong-Seo
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.1-8
    • /
    • 2003
  • In this study, the high performance BCD device structure which satisfies the high voltage and fast switching speed characteristics is devised. Through the process and device simulation, optimal process spec. & device spec. are designed. We adapt double buried layer structure, trench isolation process, n-/p-drift region formation and shallow junction technology to optimize an electrical property as mentioned above. This I.C consists of 20V level high voltage bipolar npn/pnp device, 60V level LDMOS device, a few Ampere level VDMOS, 20V level CMOS device and 5V level logic CMOS.

  • PDF

Design of Roller-Type Metering Device for Precision Planting (정밀 파종용 롤러식 배종장치의 설계)

  • 류일훈;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.401-410
    • /
    • 1997
  • Scattering of seeds is one of the problems in the hill- dropping planters with a roller-type metering device. For crops like rice, corns and beans, the hill-dropping is own better for a high yield than the drill planting. The roller type metering device has been used for the drill planters and has many advantages. However, it has a problem of scattering of seeds when they are placed on rows. In this study a method was developed to design the roller type metering device fir the precision hill-droppings. Design parameters were derived to configure completely the geometries of the roller and brush. The method was applied to the design of the metering device of the rice seeding machines. The field test showed that the metering device designed by the method made a better performance of seed placement than that made by the precvious one. The method also can be applied to the design of metering devices for the precise hill-droppings of other crops.

  • PDF

Basic Study on Safety Accident Prevention System Development Using Wearable Device (웨어러블 장치를 이용한 건설사고 예방 시스템 개발 기초 연구)

  • Ryu, Han-Guk;Kang, Jin-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.55-56
    • /
    • 2018
  • In order to reduce the risk of accidents, we proposed a construction safety management system combined with wearable device and LoRa (Low-Range Wireless Network) communication method to apply the usefulness of Internet (IoT) technology which means "everything connected". to construction safety management Management system. The proposed wearable safety device is a device that relays information exchange between wearable safety device and safety management server by LoRa wireless communication method. The safety management server can store workers bio-data and perform big data analysis. If a risk factor is determined from the analysis result, a warning is sent to the wearable safety device and the manager's application. The goal of this system is to prevent construction workers from entering the dangerous area that is not suitable for work, and to prevent safety accidents caused by human cause by detecting abnormal condition during work.

  • PDF

Design and Development of a Monitoring System based on Smart Device for Service Robot Applications

  • Lee, Jun;Seo, Yong-Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.35-41
    • /
    • 2018
  • Smart device has become an affordable main computing resource for robotic ap-plications in accordance with a fast growth of mobile internet environment. Since the computing power of smart device has been increased, smart device based ro-bot system attempts to replace traditional robot applications with laptop-based system. Methodologies for acquisition of remote sensory information and control of various types of robots using smart device have been proposed recently. In this paper, we propose a robot control system using a monitoring program and a communication protocol. The proposed system is a combination of an educa-tional programming oriented robot named EPOR-S. as small service robot plat-form and a smart device. Through a simulation study using image processing, the feasibility of combination of the proposed robot monitoring program and control system was verified.