• Title/Summary/Keyword: office room

Search Result 288, Processing Time 0.039 seconds

Studies on the Preservation of Potato by Combination of Gamma-Radiation and Chemical (방사선(放射線) 및 화학약품(化學藥品) 겸용처리(兼用處理)에 의한 감자의 저장연구(貯藏硏究))

  • Kim, Sung-Kih;Park, Nou-Pung
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.159-167
    • /
    • 1975
  • Present work was conducted to investigate the combined effects of gamma-radiation and chemical treatment on the inhibition of sprouting and decay of potato tubers. Irish Cobbler, Apollo and Shimabara potato tubers were immersed in 1000, 2000 and 3000 ppm solution of salicylic acid for 2 minutes, and then irradiated at doses of 5, 10, and 15 krad using an indoor gamma room of approximately 10,000 Ci of $^{60}Co$. Treated tubers were stored for 8 months at room temperature. The results of this work are summarized as follows: 1. Moisture content of irradiated potato tubers was changed less than the control, and decreased gradually along with an extended storage period. Ascorbic acid content was remarkably decreased by gamma-radiation and an extended storage period. 2. Reducing sugar content of irradiated potato tubers tended to increase greatly compared with unirradiated potato tubers, however, starch content of irradiated potato tubers decreased compared with the control. Reducing sugar and starch content of all groups also decreased gradually along with an extended storage period. 3. The storageability of Irish Cobbler variety was best among three varieties and Shimabara variety was worst among them when gamma-radiation is treated singly or in combination with the chemical. Sprouting of potato tubers was more suppressed in combination treatment than single treatment. 4. Decay of potato tubers was more reduced in combination treatment than single treatment. Chemical treatment or gamma-radiation followed by chemical treatment had no influence on decay or spronting of potato tubers. 5. Weight loss of potato tubers was considerably increased as storage period became extended. Shrinkage was, more serious in Shimabara than in rish Cobbler.

  • PDF

A Study on the Illumination of Household and Research on the Actual Conditions of Wearing Spectacles in Dwellers (주택의 조명과 거주자의 면경착용 실태조사연구)

  • 석호작;남철현
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.54-66
    • /
    • 1991
  • As a result of measuring illumination and making up a question at home visit directly by investigator who trained over twenty days period from October 4 to 24, 1990, in order to render help which illumination problem against house, society against eyes or framing of health instruction potgram by seizing natural lighting actual conditions of house and actual conditions of wearing spectacles and by investigating interrelationship, I can summarize as follows. 1) In property of investigation subject, woman 66.9%, In an age, the twenties was largest of 27.4%, the forties was 20.2%, the fifties was 18.6%, the thirties was 17.4%. In academic career, those of upper secondary school grauates was largest of 28.6%, those who possess university career was 25.9%, those who middle school career was 20.9%, decoding of Korean alphabet was 2%. 2) By a residence area, a big city was 43.3%, farming and fishing villages were 20.3%, the rest was a small town and the administrative office of town, township. In positon of house, the middle area was 43.6%, resident of suburb area was 38.0%. In form of house, a Korean-style house was 40.8%, a western-style house was 34.8%, an apartment house was 11.0%. In the a standard of living, the middle classes 77.2%, the lower classes were 15.3%. In residential house unit of area, from 21 to 30 unit of area was largest of 31.5%, from 10 to 20 unit of area was 19.9%, from 31 to 40 was 18.7%. 3) The wearing spectacles rate of study user was 44.1%. By the area, those who wearing spectacles was more than a half of 50.8% in the resident of big city area. As passing from the farm area to the city, that is being resident of big city was high wearing spectacles rate. In position of house, as being residence in central street showed high wearing spectacles rate. (central street was 51.5%, the middle area was 44.5% and the suburb area was 40.1%.) It seemed similarity difference a variable by position of house from wearing spectacles in standard of 1%. By form of house, wearing spectacles rate those who resident in apartment house was 49.5%, that rate those who resident in a western-style house was high of 49.0%, that rate those who resident in a Korean-style house was the lowest 39.0%. By social position of resident in room, in students case who study showed very high, as university students were very high of 62.3% idn wearing spectacles rate, middle and high school students 'were 50.0%, members of society were 47.6%, workers 20.3%. It seemed similarity difference from academic career in standard of 1%. By an age, the thirties was high of 54.1% in wearing spectacles rate, the twenties was 43.2%, the teenage was the lowest of 11.8%. 4) In illumination of study, over 200Lux was high of 40.1%. but below 99Lux which inappropriate illumination to see the books was 32.4%. Average by area, below 99Lux was 22.7% and over 400Lux was 50.0% in case of wooden floor. As examine by area, below 99Lux was high of 27.0% a case of wooden floor in the big city area, it was not good in illumination passing from the farm area(15.0%) to the city(19.0%). Average illlumination by area of the main living room below 99Lux was high of 37.5%, less than 200Lux was 58.5% of whole. In general, illumination of the main livingroom was inappropriate. By area, the big city was 32.5% below 99Lux, the middle and small city area were 33.8%, town and township area were 45.0%, farming and fishing area were 42.8%. By area, in the big city, illumination of study was 52.5% over 200Lux and 28.9% below 99Lux. In case of the middle and small city, study user of below 99Lux was 38.8% and over 200Lux was 46.9%. In case of the seat of town township, below 99Lux was 34.1% and over 200Lux was 39.7%. In case of farming and fishing area, illumination of study was 33.4% below 99Lux and 48.4% over 200Lux. It tends to high rate of inappropriate illumination. 5) By position of house, in case of wooden floor, less than 100Lux was 24.5% in central street. It was bad illumination than others position of house. In case of the main livingroom, less than 100Lux was 40.4% in the suburb area. It was bad iliumnation than others position of house. In case of study, less than 100Lux was 35.4% in the middle area, it was worse in illumination. In case of the main living room, is seemed similarity difference in standard of 1%. 6) By form of house, in case of wooden floor, illumination of less than 100Lux was 23.8% in a western-style house, it was bad illumination than others form of house. In case of the main livingroom, illumination of less than 100Lux was 47.4% in a Korean-style house, it was remarkably bad illumination than others form of house. In case of study, a Korean-style house was 38.8%, it was very bad illumination than others form of house. In case of the main livingroom and study, it seemed similatrity difference each as P < 0.01 and P < 0.05 in standard of 1%. 7) The wearing spectacles rate of those who use room of illumination over 400Lux was 40.7%, and that of those who use room of illumination less than 100Lux was 28.1%. It seemed similarity differecce in standard of 1%. 8) In period of wearing spectacles, 21.3% of total investigator-highest-was from before five years, 8.6% was from before three years. Among those who use of illumintion less than 99Lux, 34.0% began to wear spectacles from before two years 31.7% was from before five years, 30.3% was from before four years. It seemed similarity difference from period of wearing spectacles by illumination in standard of 1 %. 9) Among cause which sight grow worse, the first was that it was each 33.2% and 27.4% in response rate because watch TV nearly to wearing spectacles person and non-wearing person. The second was that a lot of seeing books was 25.3% in wearing spectacles person and response rate for dark illumination was 7.4% in nonwearing spectacles person. It seemed similarity difference in standard of 1%. (P < 0.01). 10) In experience which take medicine good for eyes, it was 50.1% in wearing spectacles person and 8.5% in non-wearing spectacles person. It seemed similarity difference in standard of 1%(P < 0.01). As we have seen above, inappropriate illumination can be a cause of wearing spectacles. Nevertheless, actually, is realities to indifferent against illumination of house. So it must learn knowledge about health obstacle of illumination through society instruction and school eduction against students as well as general residents. In case that natural lighting is inappropriate structural of house, we must be able to maintain appropriate illumination through artificial illumination. And so eyes which is core of human life have to be protected, related the authorities, related group, and all health medical personnel will organically cooperate with and make efforts.

  • PDF

A research on remodelling of the laboratory of S high school of broadcasting for converting into specialized one in the section of broadcasting industry (방송 산업 분야의 특성화고등학교로 전환을 위한 S방송고등학교의 실험.실습실 리모델링에 관한 연구)

  • Oh, Seung-gyun;Lee, Myung-Eui;Lee, Yong-soon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.87-112
    • /
    • 2009
  • The aim of this research is to suggest the model of reconstruction and remodelling of S high school of broadcast for converting into a specialized one in the section of broadcast industry. The method of reconstruction of the laboratories by each department is as follows. First, the names of laboratories, ground plans, and perspective drawings are designed according to the principle of constructionism. Second, each department is recommended to install 7 laboratories. For the department of broadcasting facilities, a laboratory of processing broadcasting machines, a laboratory of broadcasting machines, and a laboratory of screen picture machines are needed. For the department of broadcasting, electricity, and communication, a laboratory of image and sound edition, a laboratory of broadcasting and communication, a laboratory of broadcasting system, and a laboratory of stage illumination. For the department of broadcasting stage construction, a laboratory of broadcasting stage building, a laboratory of broadcasting stage design, a laboratory of broadcasting stage decoration and etc. Third, an office room is designed by department in the form of seminar room and places for practice is formed by department to be a laboratory. Fourth, a room for industrial-educational cooperation is installed by department, by which education of industrial-educational cooperation is carried out harmoniously. And one example of a remodeled laboratory by one department is shown with laboratory name, ground plan, perspective drawing, and running method. Especially employment of teachers working both school and business, professional club which is concerned with broadcasting technique, and attraction of enterprise in school is suggested as important elements to manage broadcasting laboratories efficiently. Finally, it is desirable for us to attract private capital, that is, Build-Transfer-Lease(BTL) because much budget is required for purchasing the broadcasting equipments and remodelling the laboratories to succeed as specialized high school on broadcasting section.

An Experimental Study on Characteristics of Averaged Electromagnetic Properties considering Moisture Changes in Cement Mortar (시멘트 모르타르의 수분변화에 따른 평균화된 전자기 특성에 대한 실험적 연구)

  • Kwon, Seung-Jun;Maria, Q. Feng;Na, Ung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • Many researches on electromagnetic (EM) properties like dielectric constant and conductivity are performed since they can be characterized in nonmetallic cement-based material such as mortar and concrete. However, they are much affected by the moisture so that the behaviors of EM properties are to be clearly understood. In this paper, measurements for saturation and EM properties are performed for cement mortar specimens with five different water to cement (W/C) ratios including basic tests like compressive strength and porosity measurement. Every saturated specimens are exposed to room condition and the changes in EM properties caused by decreasing saturation are analyzed. In the saturated condition, higher measurement of EM properties are evaluated in the specimens with higher porosity, however this relationship is adversely changed with drying process. Since the pores without filled water causes the decreases in EM properties, the measurements show stable and linear increment with the lower W/C ratios. Furthermore, the increasing ratios of EM measurements with W/C ratio are shown with saturation and the relationships between them are derived through regression analysis.

The Effect of Anchorage with Shear Reinforcement in Flat Plate System (플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과)

  • Choi, Chang-Sik;Bae, Baek-Il;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.667-675
    • /
    • 2012
  • Flat plate are being used more in buildings requiring a high level of technical installations or in buildings needing changeable room arrangements during their life time such as office buildings. The main problem in flat plate is its weak resistance against a punching failure at its slab-column connections. Therefore, in this research, an experimental study on full-scale interior slab-column connection was performed. Three types of shear reinforcements were tested to prevent brittle punching shear failure that could lead to collapse of the structure. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with shear reinforcements were tested. The slabs were tested up to failure using monotonic vertical shear loading. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slabcolumn connections. The test results showed that a slab that did not have enough bond length failed before shear reinforcement yielded due to anchorage slip. Also, FEM analyses were performed to study an effect of slab thickness and concrete compressive strength on the flat plate slab. The analytical study results were used to propose a method to calculate performance capacity of shear reinforcement in slab-column connection.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study (각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.191-200
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Improbability of Root Infection by the Pine Wood Nematode in Sawdust Discharged from Chain Saw Lumbering of Infected Trees (감염목 벌채 톱밥에 포함된 소나무재선충의 뿌리 감염 불가능성)

  • Lee, Seung-Kyu;Park, Joo-Young;Lee, Chong-Kyu;Whang, Jin-Hyun;Moon, Il-Sung;Cheon, Hyang-Mi;Heo, He-Soon
    • Research in Plant Disease
    • /
    • v.16 no.3
    • /
    • pp.299-305
    • /
    • 2010
  • Objective of this study is to examine whether pine wood nematode (PWN: Bursaphelenchus xylophilus) in the sawdust discharged from infected trees cause pine wood disease or not. For this, survival time of PWN in soil was examined in which soil moisture was controlled as 15%, 22.5%, and 30% in volume ratio, respectively. The pathogenicity tests were conducted under greenhouse and field conditions. Survival time of PWN in soil was about three days in the saturated (about soil moisture of 23% in volume ratio) and dark condition between 25 and $28^{\circ}C$ of room temperature. None of potted seedlings with non-wounded roots was infected by PWN in sawdust. In field, pine wood disease was not occur in any pine trees. These results indicated that PWN discharged on soil when the infected trees were cut by chain saw can not cause pine wood disease.

An Analysis of A Comparison of Digital Movie Remake with Original Animation (영화 <블러드> 분석 : 애니메이션과 디지털 영화 버전의 비교)

  • Lee, Youn-H.
    • Cartoon and Animation Studies
    • /
    • s.22
    • /
    • pp.17-30
    • /
    • 2011
  • This paper analyzes Blood: the Last Vampire (2009) in comparison with the original Blood: the Last Vampire (2000). This digital movie, released in 2009, faithfully re-presents the visual of the original animation using more budget and more developed technology. Though these two movies share very similar visual style, they have slightly different modes of expression that can be easily detected in their opening scenes. The original Blood chooses to tell its story in more indirect way. Some shots are intentionally vague and forcefully separated by black credit screen, leaving audience guessing exactly what happened. The remake version of Blood provides faster, more diverse, and more sophisticated images. It also uses invisible and slick editing, leaving no room to guess. These differences comes mainly from the difference of media. However, since the differences between two movies lie mainly in their narratives, we can ascribe the box office slump of the digital movie version of Blood: the Last Vampire to its narrative flaws. The heroin's inner conflicts were not convincing enough, supporting roles were not probable enough, and the whole story was not unique enough. As a result, the new Blood: the Last Vampire became another bad example that shows the importance of narrative in films.

  • PDF

The Study of Permeation Characteristics for Pure Carbon Dioxide and Methane, and Gas Mixture in Cellulosic Membrane (셀룰로오스 분리막을 통한 순수 이산화탄소 메탄 및 혼합기체의 투과 특성 연구)

  • Kim, Hyun Joon;Kim, Hong Il;Kang, Yong Soo;Hong, Suk In
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.605-613
    • /
    • 1996
  • The permeation characteristics were investigated for pure carbon dioxide and methane through asymmetric cellulose acetate(CA) membrane, composite cellulose acetate membrane and asymmetric cellulose triacetate(CTA) membrane. In particular, the effect of operating pressure on the permeation performance was examined. And the permeation behavior for a mixture of carbon dioxide and methane ($CO_2/CH_4=57.6/42.4$) was also investigated and compared to the characteristics obtained from pure gases. The experiments were run at the range of partial pressure from 25 to 125 psig, and room temperature. The permeation behaviors of the CA composite and CTA membrane were similiar to those of the CA membrane. The permeation rates of pure carbon dioxide for CA, CA composite and CTA membrane were increased slightly with an increase in upstream partial pressure, while in the case of pure methane they were independent of upstream partial pressure. For a binary mixture of carbon dioxide and methane, abnormal permeation behaviors were observed due to the plasticization of carbon dioxide and the competition effect of each gas. The separation factor and permeation rate for CTA membrane were found to be higher than those for CA membrane, but the mechanical strength of CTA membrane was very poor. And the permeation rate for CA composite membrane was higher than that for CA membrane. Consequently, it can be said that the CA composite membrane is a strong candidate for the separation of $CH_4$ and $CO_2$.

  • PDF