• Title/Summary/Keyword: off pump

Search Result 304, Processing Time 0.02 seconds

The Comparison of Clinical Outcomes of Off-pump versus On-pump Coronary Artery Bypass Grafting in Diabetes Patients (당뇨 환자에서 시행한 Off-pump CABG와 On-pump CABG의 비교 연구)

  • 송석원;임상현;홍순창;조수진;장병철;강면식;신혜란;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.553-558
    • /
    • 2004
  • Avoiding cardiopulmonary bypass (CPB) in coronary artery bypass grafting (CAB G) has been known to reduce early mortality and morbidity. Diabetes Mellitus is a significant risk factor for adverse early and late outcomes after CABG. We compared the clinical results of off-pump CABG versus on-pump CABG in diabetes patients. Material and Method: 682 patients (424 off-pump CABG and 258 on-pump CABG) underwent isolated coronary artery bypass grafting between January 2001 and June 2003. Data were collected 242 patient who had diabetes. Among them, 154 patients underwent off-pump CABG and 90 patients underwent on-pump CABG. We analyzed the preoperative risk factors and postoperative results between 2 groups. Result: Two groups did not show statistical differences in age, sex, coronary and operative risk factors. Operative time was significantly shorter in off-pump CABG, however, number of grafts was fewer in off-pump CABG. Postoperative inotropic usage was lower in off-pump CABG. Postoperative CK-MB level was lower in off-pump CABG, and ICU stay and ventilation time was significantly shorter in off-pump CABG. However, there was no statistical difference between 2 groups in operative mortality, reoperation rate, perioperative myocardial infarction, wound infection, renal failure, neurological complications and hospital stay. Conclusion: Off-pump CABG group showed less myocardial damage and early recovery. We concluded that off-pump CABG is the more reasonable technique in diabetes patients although two techniques showed good results. The long-term follow up and prospective study may be warranted.

The Comparison of Clinical Outcomes of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in High Risk Patients (고위험군 환자에서 시행한 On-Pump CABG와 Off-Pump CABG의 비교연구)

  • 윤영남;이교준;김치영;안지영;오영준;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.749-754
    • /
    • 2004
  • Off-pump coronary artery bypass grafting (Off-Pump CABG) has been proven to have less morbidity and to facilitate early recovery. High-risk surgical patients may have benefitted by avoiding the adverse effects of the cardiopulmonary bypass. We compared the effectiveness of Off-Pump CABG with that of coronary artery bypass using cardiopulmonary bypass (On-Pump CABG) in high-risk patients. Material and Method: 682 patients (424 Off-Pump CABG and 258 On-Pump CABG) underwent isolated coronary artery bypass grafting between January 2001 and June 2003. Patients who were considered high risk were selected High risk is defined as the presence of one or more of nine adverse prognostic factors. Data were collected from 492 patients in Off-Pump CABG and 100 in On-Pump CABG for risk factors, extent of coronary disease, and in-hospital outcomes. Result: Off-Pump CABG group and On-Pump CABG group did not show differences in their preoperative risk factors. We used more arterial grafts in Off-Pump CABG group (p < 0.05). Postoperative results showed that operative mortality (0.5% in Off-Pump CABG versus 2.0% in On-Pump CABG), renal failure (2.6% in Off-Pump CABG versus 7.0% in On-Pump CABG), and perioperative myocardial infarction (1.5% in Off-Pump CABG versus 1.0% in On-Pump CABG) did not differ significantly. However, Off-Pump CABG had shorter mean operation time (p<0.05), lower mean CK-MB level (p <0.05), lower rate of usage of inotropics (p < 0.05), shorter mean ventilation time (p <0.05), lower perioperative stroke (0% versus 2.0%), and shorter length of stay (p < 0.05) than On-Pump CABG. On-Pump CABG had more distal grafts (p<0.05) than Off-Pump CABG. Although Off-Pump CABG and On-Pump CABG did not show statistical differences in mortality and morbidity was more frequent in CABG. Conclusion: Off-Pump CABG reduces morbidity and favors hospital outcomes. Therefore, Off-Pump CABG is safe, reasonable and may be a preferable operative strategy for high-risk patients.

The Comparison of Clinical Study of Off Pump and On Pump CABG (On Pump-CABG와 Off Pump-CABG의 임상적 고찰에 관한 비교연구)

  • 유경종;임상현;송석원;김치영;홍유선;장병철
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.261-266
    • /
    • 2002
  • In an attempt to avoid the adverse effects of the cardiopulmonary bypass, off pump coronary artery bypass grafting(Off pump CABG) that has recently been rediscovered and refined. We compared the preoperative risk factors and in-hospital outcomes of patients done Off pump with those done On pump CABG. Material na Method: One hundred seventy eight patients was underwent CABG between January 2001 and July 2001 12 patients whom underwent associated valvular or left ventricular volume reduction surgery were excluded in this study Data were collected for 52 Off pump CABG and 114 On pump CABG for patient and disease risk factors, extent of coronary disease, and in-hospital outcomes. Result: Off pump CABG and On pump CABG groups did not show any differences in their patient and disease risk factors, and extent of coronary disease. Off pump CABG group had significantly lower mean operation time(234 $\pm$ 37 min vs 290 $\pm$ 48 min, p<0.001), lower mean CK-MB level(10.1 $\pm$ 13.5 IU/L vs 33.1 $\pm$ 18.2 IU/L, p<0.001) and mean ventilation time(14.8 $\pm$ 3.5 hours vs 16.2 $\pm$ 4.9 hours, p=0.048) than On pump CABG groups. On pump CABG group had significantly more distal grafts(3.4 $\pm$ 0.9 vs 2.6 $\pm$ 0.8, p<0.001) than Off pump CABG groups. There were no operative mortality in two groups. Off pump) CABG and On pump CABG groups did not show any differences in their postoperative complications and outcomes including perioperative myocardial infarction, stroke, respiratory failure, renal failure, reoperation, the amount of bleeding, the need of intraaortic balloon pump, the need of inotropics, and the stay of intensive care unit and hospital. Two patients were converted to On pump CABG. Conclusion: This study showed that patients having Off pump CABG are not exposed to a greater risks of adverse outcomes and also provided evidence that patients having Off pump CABG have significantly lower operation time, CK-MB, ventilation time and less distal grafts. Although there may be potential benefits to Off pump CABG, further studies must be directed to determine those patients who would benefit from Off pump CABG.

A Comparative Study Between On-Pump and Off-Pump Coronary Artery Bypass Grafting on Clinical Outcomes

  • Moon Seong-Min;Choi Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.237-243
    • /
    • 2004
  • In recent, many cardiac centers have preferred off-pump coronary artery bypass grafting (CABG) to on-pump CABG to prevent the adverse effects of cardiopulmonary bypass. The present study was performed to prove beneficial effects of off-pump CABG. Sixty adult patients scheduled for elective CABG were randomly assigned to On-pump group (n=30) or Off-pump group (n=30). Arterial blood samples were drawn before and after the operation (Pre-OP and Post-OP, respectively) for measuring CBC, prothrombin time, activated thromboplastine time, blood gas analysis, creatine kinase-MB (CK-MB) level, and lactate dehydrogenase (LDH) level. Perioperative parameters including heparin and protamine usages, complications, blood components usages, blood loss, ventilation and ICU-staying time, and hospitalization were also evaluated. Platelet count at Post-OP was high in Off-pump group whereas CK-MB and LDH levels were low compared with On-pump group. Off-pump group had significantly lower heparin and protamine usages, lower total leukocyte count, higher hematocrit and hemoglobin levels, less blood loss, lower usages of blood components, shorter ventilation and ICU-staying time, and lower incidence of pleural effusion than On-pump group. Other variables did not significantly differ between two groups. These results showed that Off-pump CABG was a satisfactory technique with less inflammatory reaction, less cardiac damage, less postoperative complications, and less cost.

  • PDF

Early and Midterm Outcome of Redo Coronary Artery Bypass Grafting: On-Pump versus Off-Pump Bypass

  • Shin, Yu Rim;Lee, Sak;Joo, Hyun Chel;Youn, Young-Nam;Kim, Jong Gun;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.225-232
    • /
    • 2014
  • Background: Redo coronary artery bypass grafting (CABG) is still associated with increased morbidity and mortality as compared to the first-time operation. Further, the application of the off-pump technique to redo CABG is limited due to technical difficulties. The aim of this retrospective study was to analyze early and midterm results after redo CABG and compare the outcome of redo on-pump and off-pump CABG. Methods: From June 1996 to October 2011, elective redo CABG was performed in 32 patients. Mean age was 64.8 years (on pump 64.3 years vs. off pump 65.5 years; p=0.658), and 21 patients were male. Among these patients, 14 (43.8%) underwent on-pump CABG, and 18 (56.2%) underwent off-pump CABG. Results: Internal thoracic artery was used in 22 patients (68.8%), and total arterial revascularization was achieved in 17 patients (53.1%). The average number of distal anastomoses was 2.13, and the rate of incomplete revascularization was 43.8%. The rate of total arterial revascularization was higher in the off-pump group (14.3% vs. 83.3%, p<0.001), and the use of saphenous vein graft was more in the on-pump group (78.6% vs. 16.7%, p<0.001). Overall hospital mortality was 3.1% (n=1) and was comparable in both groups (on pump 7.1% vs. off pump 0%; p=0.249). Postoperative complications occurred in 9 patients (64.2%), and the rate of complications was high in the on-pump group without statistical significance (64.2% vs. 33.3%, p=0.082). The mean follow-up duration was 5.4 years, and overall survival at 10 years was $86.0%{\pm}10.5%$. There was no significant difference in the 10-year survival rate between the two groups (79.6% vs. 100%, p=0.225). Conclusion: Redo CABG can be safely performed with acceptable mortality. Redo off-pump coronary artery bypass is feasible with low mortality and morbidity, comparable target vessel bypass grafting, and long-term survival. The off-pump technique might be considered a safe option for redo CABG in high-risk patients.

Off-pump CABG for Unstable Angina Complicated With COPD (만성폐쇄성 폐질환을 동반한 불안정성 협심증환자에서 off-pump 관상동맥우회술)

  • 곽기오
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.186-189
    • /
    • 2000
  • In an attermpt to aviod the deleterious effects of cardiopulmonary by pass such as pulmonary complication neurologic complication and renal failure off-pump CABG has been rediscovered and developed. We experienced off-pump CABG in 2 cases with unstable angina complicated with COPD and report herein the cases with review of literature.

  • PDF

On-Pump versus Off-pump Myocardial Revascularization in Patients with Renal Insufficiency: Early and Mid-term Results

  • Kim, Hwan-Wook;Lee, Jae-Won;Je, Hyung-Gon;Choi, Soo-Hwan;Jo, Keon-Hyon;Song, Hyun
    • Journal of Chest Surgery
    • /
    • v.44 no.5
    • /
    • pp.323-331
    • /
    • 2011
  • Background: Myocardial revascularization in patients with renal insufficiency is challenging to the cardiac surgeon, irrespective of utilizing extracorporeal circulation. This study aimed to compare the number of bypass grafts and the mid-term results and to evaluate independent survival predictors in patients with renal insufficiency undergoing on-pump or off-pump myocardial revascularization. Materials and Methods: We retrospectively analyzed the data of 103 patients with renal insufficiency, who had isolated myocardial revascularization between January 1999 and January 2009. The patients were divided into two groups, the on-pump group and the off-pump group. Results: The off-pump group received a significantly greater number of distal arterial grafts than the on-pump group. However, the mean number of total grafts, the degree of complete revascularization, and survival rate of the patients were not significantly different between the two groups. Multivariate analysis showed the independent predictors for reduced mid-term survival were the number of total grafts and postoperative periodic renal replacement therapy. Off-pump myocardial revascularization does not decrease the number of bypass grafts or influence on the mid-term results for patients with renal insufficiency, compared to on-pump myocardial revascularization. Conclusion: Myocardial revascularization with a large number of total grafts has a beneficial effect on survival in patients with renal insufficiency, irrespective of utilizing extracorporeal bypass.

Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

Clinical Results of 100 Cases of Coronary Artery Bypass Grafting without Cardiopulmonary Bypass (심폐바이패스 없이 시행한 관상동맥 우회술 100예의 임상적 고찰)

  • 방정희;우종수
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.322-327
    • /
    • 2004
  • Coronary artery bypass grafting on the beating heart is no longer a new methods for any cardiac surgeon. We evaluated the application of the off-pump coronary artery bypass procedure relative to safety and efficiency as measured by postoperative complication and operative mortality. Material and Method: We used our retrospective database to compare the patients having off-pump coronary surgery (n=100) with those having on-pump coronary surgery (n=100) between June, 1999 and August, 2002. Patients whom underwent associated valvular or aortic aneurysmal operation were excluded. Result: Neither groups showed any differences in the patient's risk factors and extent of coronary disease. Off-pump CABG group did not have significantly less mean operation time (295$\pm$73 min vs 323$\pm$83 min, p=ns) and mean hospital day (15.34$\pm$6.02 day vs 13.80$\pm$4.95 day, p=ns). However, off-pump CABG group had significantly shorter mean ventilation time (17.3$\pm$11.27 hour vs 24.98$\pm$16.1 hour, p<0.05). No patients were converted to on-pump CABG in off-pump CABG. Intraoperative hemodynamic instability in off-pump CABG were 6 cases, of whom 2 cases were in lateral wall approach and 4 cases in right coronary anastomosis. Postoperative mortality was 1 case in off-pump CABG and 2 cases in on-pump CABG. Intra-aortic ballon pump (IABP) was applied in 1 case with off-pump CABG and in 2 cases with on-pump CABG. No patients presented postoperative cerebral infarction & stroke in off-pump CABG but 2 patients in on-pump CABG. Postoperative arrhythmia presented in 4 cases with off-pump CABG and in 6 cases with on-pump CABG. Acute renal failure (ARF) was complicated in 3 cases with off-pump CABG and in 2 cases with on-pump CABG. Conclusion: This study documented the immediate safety and efficiency of the off-pump CABG procedure.

Results of Protocol-based Perioperative Management in Off-Pump Coronary Artery Bypass Grafting for Patients with Non-dialysis-dependent Chronic Kidney Disease

  • Kim, Jeong-Won;Sim, Hyung Tae;Yoo, Jae Suk;Kim, Dong Jin;Cho, Kwang Ree
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.427-434
    • /
    • 2016
  • Background: Recent studies have demonstrated the benefits of off-pump coronary bypass grafting over the on-pump technique in patients with chronic kidney disease (CKD). To further reduce the risk of acute kidney injury and the need for renal replacement therapy, even in patients undergoing off-pump coronary artery bypass grafting, we adopted protocol-based perioperative management for patients with CKD. Methods: From December 2012 to March 2015, 265 patients underwent isolated off-pump coronary artery bypass grafting. To analyze renal function in a stable condition, we excluded 12 dialysis-dependent end stage renal failure and 10 emergency or urgent cases. Among the remaining 243 patients, 208 patients had normal kidney function (normal group), and 35 patients had CKD (CKD group). Minimizing contrast exposure, ensuring adequate hydration, using strict drug dosage adjustment, and optimizing hemodynamic status were key elements of the protocol for the CKD group. Results: The risk of acute kidney injury was about ${\times}3$ higher in the CKD group than in the normal group (p=0.01). Estimated glomerular filtration rates and serum creatinine levels deteriorated until the third postoperative day in the CKD group. However, by adopting protocol-based perioperative management, this transient renal dysfunction recovered to preoperative levels by the fifth postoperative day without requiring renal replacement therapy in all cases. Conclusion: Off-pump coronary bypass surgery combined with this protocol-based perioperative management strategy in patients with non-dialysis-dependent CKD could mostly be performed without renal replacement therapy.