• Title/Summary/Keyword: ocean discharge

Search Result 421, Processing Time 0.034 seconds

Reduction of the Foam Generated in the Discharge Channel of a Power Plant (발전소 배수로에서 발생하는 거품 저감 방법)

  • Oh, Young-Min;Oh, Sang-Ho;Jang, Se-Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.235-240
    • /
    • 2010
  • The foam produced by the effluent cooling water which is released to the discharge channel provokes civil complaints due to the visual pollution to the neighboring residents. In this study, a physical model test was conducted by placing tetrapods on the bottom slope of the discharge channel in order to suggest an effective method of reducing the amount of generated foam. Field application of the main results of the model test showed qualitatively apparent reduction of the foam generation at the discharge channel.

Numerical Modeling on the Change in Discharge Performance of the Sluice for Tidal Power Plant According to the Apron Shape (물받이 형상에 따른 조력발전용 수문의 통수성능 변화 수치모델링)

  • Oh, Sang-Ho;Han, In-Suk;Kim, Gunwoo;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.94-102
    • /
    • 2013
  • In this study, numerical modeling was performed to investigate influence of the apron shape on the discharge performance of the sluice for tidal power plant. The numerical modeling was carried out for comparison of the difference in the discharge coefficient when the apron width, slope, and the length of the horizontal section were different, without considering change in the shape of the sluice caisson itself. The modeling result showed that significant discrepancy in terms of the overall discharge performance appeared according to the apron geometry. In order to achieve maximum discharge performance of the sluice caisson, it is desirable to make the design by putting a space equivalent to the width of the sluice caisson on its both sides, by making the apron slope be 1:5, and by keeping length of the horizontal section to be 50 m that is corresponding to the streamwise length of the sluice caisson.

Spectral analysis for thermal discharge of Hadong Power Plant (하동화력 발전소 온배수에 대한 Spectrum 분석)

  • Park, Il-Heum;Lee, Geun-Hyo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.435-440
    • /
    • 2006
  • In order to understand changes of water temperature for thermal discharge of Hadong power plant in Gwangyang and Jinju Bay, it was analyzed for temperature data of representative season by MEM(Maximum entropy method) that is one of the spectral analysises. And due to understand effect of thermal discharge at each point, analyzed spectral data showed reactive energy rate of reference point by calculating energy from 24 time period to height frequency zone. As a result of spectral analysis, it showed that there were 9 points which are largely effected, 7 points which will be estimated, 6 points which is difficult to estimate, 14 points which rarely effected by thermal discharge.

  • PDF

A Study on the Discharge System of Thermal Waste Water (온배수 방류시스템에 관한 기초적 연구)

  • Kwak, Ki-Su;Jeon, Yong-Ho;Kim, Heon-Tae;Ryu, Cheong-Ro;Lee, Kyung-Seon
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.87-94
    • /
    • 2007
  • This study used POM (Princeton ocean model) improved for applying to coastal area in order to predict the distribution of thermal waste water. This model was applied to the coastal circulation and the effect of thermal waste water of Cheonsu-Bay. So this study compared the discharge of thermal waste water with each layer and section. The tidal current was about 1.5 m/sec at surface level and 0.9 m/sec on bottom level at flood tide; tidal current was about 1.3 m/sec on surface level and 0.8 m/sec on bottom level at ebb tide. The method discharging the thermal waste water in the nearshore region (case 1) accelerates the diffusion of the thermal waste water in the north-south direction(longshore direction). However, the method discharge the thermal waster water in the offshore region (case 2) reduced the diffusion of the thermal waste water over the coastal region. According th the diffusion region of the thermal waste water with case 1 and case 2 at three different layers (surface, middle, bottom), the diffusion region by case 1 discharge method generally influenced wider region (twice) than the one by case 2 discharge method with lower temperature between $1^{\circ}C\;and\;2^{\circ}C$, whereas the case 2 discharge method influenced the deeper region (middle and botton layers) with higher change of the water temperature ($1{\sim}3^{\circ}C$).

Phytoplankton Community and Surrounding Water Conditions in the Youngsan River Estuary: Weekly Variation in the Saltwater Zone (영산강 하구의 식물플랑크톤 군집 및 수 환경: 해수역의 주별 변동)

  • Sin, Yongsik;Yu, Haengsun
    • Ocean and Polar Research
    • /
    • v.40 no.4
    • /
    • pp.191-202
    • /
    • 2018
  • In this study we conducted a weekly monitoring exercise at a fixed station in the saltwater zone during the dry season (Jan-Mar, 2013) and wet season (Jun-Aug, 2013) to understand the fluctuations in phytoplankton communities and environmental factors in the Youngsan River estuary altered by a dike constructed in the coastal area. Phytoplankton communities displayed seasonality; diatoms were dominant during the dry season whereas dinoflagellates were dominant during the wet season. T-test analysis showed that water temperature was significantly different between the seasons whereas freshwater discharge from the dike was not significantly different. This suggests that seasonal variations of phytoplankton are more likely affected by water temperature than freshwater discharge. However, a short-term fluctuation was also observed in response to freshwater discharge; freshwater species appeared during or after the discharge in the dry and wet seasons and blooms of harmful species developed after the discharge. Phytoplankton communities may be affected by changes in physical factors such as turbidity and salinity and nutrient supply resulting from freshwater discharge. Especially, the nutrient supply may directly contribute to the harmful algal blooms (HABs) composed of dinoflagellates which can adapt to low salinity after freshwater discharge.

The Characteristic of Deposition in Nakdong estuary considering Tide and River discharge (조석과 하천수 유입을 고려한 낙동강 하구역의 퇴적특성)

  • Jeon, Yong-Ho;Ryu, Cheong-Ro;Lee, In-Cheol;Kim, Heon-Tae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.157-162
    • /
    • 2003
  • Nakdong estuary is located at south-eastern coast of the Korea. A lot of sediment from upper river were deposited at this area. It has cause many problem such as changes in topography and tidal current. Changes of characteristic of deposition were cause by topographic change of nakdong estuary. Analyzing and evaluating data, we could predict the direction of movement of the sand bar and the growth toward south-eastern of Nakdong estuary. It was caused by decreasing river discharge after construction of Nakdong-kang barrage.

  • PDF

Numerical Modeling for Region of Freshwater Influence by Han River Discharge in the Yeomha Channel, Gyeonggi Bay (경기만 염하수로에서의 한강 유량에 따른 담수 영향범위 수치모델링)

  • Lee, Hye Min;Song, Jin Il;Kim, Jong Wook;Choi, Jae Yoon;Yoon, Byung Il;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.4
    • /
    • pp.148-159
    • /
    • 2021
  • This study estimates the region of freshwater influence (ROFI) by Han River discharge in the Yeomha channel, Gyeonggi Bay. A 3-D numerical model, which is validated for reproducibility of variation in current velocity and salinity, is applied in Gyeonggi Bay. Distance of freshwater influence (DOFI) is defined as the distance from the entrance of Yeomha channel to the point where surface salinity is 28 psu. Model scenarios were constructed by dividing the Han River discharge into 10 categories (200~10,000 m3/s). The relation equation between freshwater discharge and DOFI was calculated based on performing a non-linear regression analysis. ROFI in Yeomha channel expands from the southern sea area of Ganghwa-do to the northern sea area of Yeongheung-do as the intensity of Han River discharge increases. The discharge and DOFI are a proportional relationship, and the increase rate of DOFI gradually decreases as discharge increases. Based on the relation equation calculated in this study, DOFI in the Yeomha channel can be estimated through the monthly mean Han River discharge. Accordingly, it will be possible to respond and predict problems related to damage to water quality and ecology due to rapid freshwater runoff.

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

Isotopic Hydrograph Separation Using Artificial Rain-on-snow Experiments and Its Implications by Each Tracer (인공강우실험을 이용한 동위원소수문분리 및 각각의 추적자에 따른 의미)

  • Lee, Jeonghoon
    • Ocean and Polar Research
    • /
    • v.38 no.4
    • /
    • pp.331-338
    • /
    • 2016
  • Many studies using tracers have been conducted to understand a physical process in a system. Rain-on-snow could accelerate snowmelt processes, which influences the hydrological process in both temperate and polar regions. Hydrological and ecological conditions will be affected by the amount and timing of discharge reaching the bottom of a snowpack. The discharge consists of the rain-on-snow, pore water penetrating into the snowpack and natural meltwater. In this study, after a rain-on-snow experiment, we conducted an isotopic hydrograph separation to distinguish rainwater and pore water from meltwater. Using the isotopic data of snow and meltwater from Lee et al. (2010), two components were separated based on the assumption that rainwater and pore water are new water and natural meltwater is old water. After the second rain-on-snow experiment, the maximum contributions of rainwater and pore water reached up to 69% of the discharge and then decreased. During the study period, the measured total discharge was 4153 L and 40% (based on hydrogen isotope) of rainwater and pore water was calculated in the discharge, which is not consistent with what Lee et al. (2016) calculated using chemical separation (63%). This inconsistency can be explained by how an end-member was defined in both approaches. The contributions of artificial rainonsnow and pore water to melwater discharge range between the two methods. This study will suggest a mixing calculation from isotopic compositions of the Southern Ocean.