• 제목/요약/키워드: objective measurements

검색결과 1,120건 처리시간 0.033초

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Risk Assessment of Physical Hazards in Greek Hospitals Combining Staff's Perception, Experts' Evaluation and Objective Measurements

  • Tziaferi, Styliani Gewrgios;Sourtzi, Panayiota;Kalokairinou, Athina;Sgourou, Evi;Koumoulas, Emmanouel;Velonakis, Emmanouel
    • Safety and Health at Work
    • /
    • 제2권3호
    • /
    • pp.260-272
    • /
    • 2011
  • Objectives: The promotion of health and safety (H&S) awareness among hospital staff can be applied through various methods. The aim of this study was to assess the risk level of physical hazards in the hospital sector by combining workers' perception, experts' evaluation and objective measurements. Methods: A cross-sectional study was designed using multiple triangulation. Hospital staff (n = 447) filled in an H&S questionnaire in a general hospital in Athens and an oncology one in Thessaloniki. Experts observed and filled in a checklist on H&S in the various departments of the two hospitals. Lighting, noise and microclimate measurements were performed. Results: The staff's perception of risk was higher than that of the experts in many cases. The measured risk levels were low to medium. In cases of high-risk noise and lighting, staff and experts agreed. Staff's perception of risk was influenced by hospital's department, hospital's service, years of working experience and level of education. Therefore, these factors should be taken into account in future studies aimed at increasing the participation of hospital workers. Conclusion: This study confirmed the usefulness of staff participation in the risk assessment process, despite the tendency for staff to overestimate the risk level of physical hazards. The combination of combining staff perception, experts' evaluation and objective measures in the risk assessment process increases the efficiency of risk management in the hospital environment and the enforcement of relevant legislation.

자연성 평가를 위한 객관적 음질 평가 방법 (Objective Speech Quality Measurement for Naturalness Assessment)

  • 장경아;이희원;송종회;배명진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(1)
    • /
    • pp.361-364
    • /
    • 2001
  • Speech quality measurement is sorted subjective and objective speech quality measurements based on the mathematics representation. Between two, subjective speech quality measurement is able to be evaluated more accurate speech quality then objective one but it has a demerit such as taking much more time and cost to performance it. However, using objective speech quality measurement being able to predict the result of evaluating the subjective speech quality compliments the demerit of subjective standards which is mentioned former. In this paper, we propose the objective speech quality measurement in order to evaluate naturalness assessment approximately like subjective speech quality measurement. We measured naturalness of speech with estimating speaking rate, variation of pitch and energy.

  • PDF

Reliability of cone-beam computed tomography for temporomandibular joint analysis

  • Gorucu-Coskuner, Hande;Atik, Ezgi;El, Hakan
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.81-88
    • /
    • 2019
  • Objective: The aim was to assess the intraobserver and interobserver reliabilities of temporomandibular joint linear measurements and condylar shape classifications performed with cone-beam computed tomography (CBCT). Methods: CBCT images of 30 patients were measured at two different time points by two orthodontists using the Dolphin 3D program (n = 60). Anterior, posterior, and superior joint space measurements and sagittal joint morphology classification in the sagittal view and medial and lateral joint space and mediolateral width measurements and coronal joint morphology classification in the coronal view were recorded. Intraclass-interclass correlation coefficients (ICC) and kappa statistics were used to assess intraobserver and interobserver reliability for the measurements and morphology classifications, respectively. Results: The ICC values were good for measurements of the posterior joint space by observer I and for measurements of the posterior, medial, and lateral joint spaces by observer II, while the other intraobserver measurements were excellent. Only the mediolateral width measurements showed excellent interobserver ICC values, while the other measurements showed good interobserver ICC values. Intraobserver agreement for the sagittal morphology classifications was moderate (${\kappa}=0.479$) and almost perfect (${\kappa}=0.858$) for observers I and II, respectively, while the corresponding agreement for the coronal morphology classifications was substantial for both observers. The interobserver agreement values for sagittal and coronal morphology classifications were slight (${\kappa}=0.181$) and fair (${\kappa}=0.265$), respectively. Conclusions: Linear temporomandibular joint measurements were reproducible and reliable in both intraobserver and interobserver evaluations. However, interobserver agreement for assessments of condylar shape was low.

몬테카를로법을 이용한 비선형 확률계수모형의 추정 (Estimation Using Monte Carlo Methods in Nonlinear Random Coefficient Models)

  • 김성연
    • 한국시뮬레이션학회논문지
    • /
    • 제10권3호
    • /
    • pp.31-46
    • /
    • 2001
  • Repeated measurements on units under different conditions are common in biological and biomedical studies. In a number of growth and pharmacokinetic studies, the relationship between the response and the covariates is assumed to be nonlinear in some unknown parameters and the form remains the same for all units. Nonlinear random coefficient models are used to analyze such repeated measurement data. Extended least squares methods are proposed in the literature for estimating the parameters of the model. However, neither objective function has closed form expression in practice. This paper proposes Monte Carlo methods to estimate the objective functions and the corresponding estimators. A simulation study that compare various methods is included.

  • PDF

Effects of dietary hatchery by-products on growth performance, relative organ weight, plasma measurements, immune organ index, meat quality, and tibia characteristics of broiler chickens

  • Choi, Won Jun;Kim, Jong Hyuk;Han, Gi Ppeum;Kwon, Chan Ho;Kil, Dong Yong
    • Animal Bioscience
    • /
    • 제34권7호
    • /
    • pp.1181-1192
    • /
    • 2021
  • Objective: The objective of the current study was to investigate the effects of dietary hatchery by-products (HBPs) as a replacement of fish meal (FM) on growth performance, relative organ weight, plasma measurements, immune organ index, meat quality, and tibia characteristics of broiler chickens. Methods: A total of 720 broiler chickens (3 d of age) were randomly allotted to 1 of 9 treatments with 8 replicates. Each replicate consisted of 5 male and 5 female birds. The basal diet was formulated to contain 5.0% commercial FM, whereas eight treatment diets were prepared by replacing 25%, 50%, 75%, or 100% of FM in the basal diet with infertile eggs (IFE) or a mixture of various HBPs (MIX); therefore, the inclusion levels of IFE or MIX in the experimental diets were 1.25%, 2.50%, 3.75%, or 5.00%. The diets and water were provided on an ad libitum basis for 32 d. Results: Increasing inclusion levels of IFE as a replacement of FM in diets had no effects on growth performance, plasma measurements, immune organ index, and tibia characteristics of broiler chickens. Increasing inclusion levels of IFE in diets increased (linear, p<0.05) meat lightness (L*) but decreased (linear, p<0.05) meat redness (a*). The breast meat pH at 1-h postmortem was increased (linear, p<0.05) by increasing inclusion levels of IFE in diets. Likewise, increasing inclusion levels of MIX in diets had no effects on growth performance, relative organ weight, plasma measurements, immune organ index, and tibia characteristics. However, increasing inclusion levels of MIX in diets increased (linear, p<0.05) 1-h postmortem pH but decreased (linear, p<0.05) 24-h postmortem pH of breast meat. Increasing inclusion levels of MIX in diets decreased (linear, p<0.05) thiobarbituric acid reactive substances values of breast meat. Conclusion: Both IFE and MIX are suitable alternatives to FM as protein ingredients in broiler diets.

Automated Surface Wave Measurements for Evaluating the Depth of Surface-Breaking Cracks in Concrete

  • Kee, Seong-Hoon;Nam, Boohyun
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.307-321
    • /
    • 2015
  • The primary objective of this study is to investigate the feasibility of an innovative surface-mount sensor, made of a piezoelectric disc (PZT sensor), as a consistent source for surface wave velocity and transmission measurements in concrete structures. To this end, one concrete slab with lateral dimensions of 1500 by 1500 mm and a thickness of 200 mm was prepared in the laboratory. The concrete slab had a notch-type, surface-breaking crack at its center, with depths increasing from 0 to 100 mm at stepwise intervals of 10 mm. A PZT sensor was attached to the concrete surface and used to generate incident surface waves for surface wave measurements. Two accelerometers were used to measure the surface waves. Signals generated by the PZT sensors show a broad bandwidth with a center frequency around 40 kHz, and very good signal consistency in the frequency range from 0 to 100 kHz. Furthermore, repeatability of the surface wave velocity and transmission measurements is significantly improved compared to that obtained using manual impact sources. In addition, the PZT sensors are demonstrated to be effective for monitoring an actual surface-breaking crack in a concrete beam specimen subjected to various external loadings (compressive and flexural loading with stepwise increases). The findings in this study demonstrate that the surface mount sensor has great potential as a consistent source for surface wave velocity and transmission measurements for automated health monitoring of concrete structures.

무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도 (Reliability and Validity of the Manual Measurement Method for Patellar Height)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

Evaluation of Video Quality Based on Objectively Estimated Metric

  • Koumaras Harilaos;Kourtis Anastasios;Martakos Drakoulis
    • Journal of Communications and Networks
    • /
    • 제7권3호
    • /
    • pp.235-242
    • /
    • 2005
  • Multimedia applications and especially encoded video services, are expected to playa major role in the 3rd generation (3G) and beyond mobile communication systems. Given that future service providers are expected to provide video applications at various price and quality levels, quick and economically affordable methods for preparing/encoding the offering media at various qualities are necessary to be developed. This paper presents a method for objective evaluation of the perceived quality of MPEG­4 video content, based on a quantification of subjective assessments. Showing that subjectively derived perceived quality of service (PQoS) vs. bit rate curves can be successfully approximated by a group of exponential functions, the proposed method exploits a simple objective metric, which is obtained from the mean frame rate vs. bit rate curves of an encoded clip. The validity of this metric is assessed by comparing subjectively derived PQoS results to the corresponding ones, which come from the proposed objective method, showing that the proposed technique provides satisfactory PQoS estimation.

원심형 터보기계의 볼류트네의 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics in Volute of Centrifugal Turbomachinery)

  • 전경준;주원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.801-806
    • /
    • 2001
  • The objective of present study is to find the interaction between volute and impeller of the centrifugal turbomachinery with rectangular cross-sectional volute. Flow measurement were taken in shrouded impeller with 12 backward type blades by using a five-hole pressure probe. The measurements are carried out in 7 flow rate, respectively. Primary function of a centrifugal turbo machinery volute is to serve the flow from the impeller and diffuser to pipe system. For the off-design conditions, Influence of pressure distortion was shown by these measurements. As a result, It has caused the decrease of total efficiency of centrifugal turbomachinery. We have also taken data to design volute by these measurements.

  • PDF