• Title/Summary/Keyword: o-xylene

Search Result 245, Processing Time 0.028 seconds

바이오필터에 의한 VOC 분해에 미치는 온도와 유입농도의 영향

  • Yun, Jin-Gil;Park, Chang-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.93-94
    • /
    • 2001
  • Biofilter operating parameters such as incoming VOCs concentrations, temperature, and packing materials were studied. The performance of a lab-scale biofilter in the treatment of air contaminated with mixtures vac has been evaluated in this study. The biofilter was operated for 80 days packed with compost. Empty bed residence time (EBRT) was 3 to 1.5 min. After 80 days of operation, the removal efficiency was 94% and 73% at $25^{\circ}C$ and $45^{\circ}C$, respectively. Removal efficiencies of m-xylene (93%), o-xylene (92%) and toluene (92%) were better than that of benzene (84.7%).

  • PDF

Characterization of BTX-degrading bacteria and identification of substrate interactions during their degradation

  • Oh, Young-Sook;Choi, Sung-Chan
    • Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.193-199
    • /
    • 1997
  • From several industrial wastewaters, 14 bacterial strains which degrade benzene, toluene, o-xylene, m-xylene, or p-xylene (BTX) were obtained. These strains were characterized as to their species composition and the substrate range, kinetic parameters and the substrate interactions were investigated. Although BTX components have a similar chemical structure, isolated strains showed different substrate ranges and kinetic parameters. None of the strains could degrade all of BTX components and most of them showed an inhibition (Haldane) kinetics on BTX, BTX mixtures were removed under inhibitory substrate interactions with variation in the intensity of inhibition. For a complete degradation of BTX, a defined mixed culture containing three different types of patyways was constructed and all of the BTX components were simultaneously degraded with the totla removal rate of 225.69 mg/g biomass/h Judging from the results, the obtained mixed culture seems to be useful for the treatment of BTX-contaminated wastewater or groundwater as well as for the removal of BTX from the contaminated air stream.

  • PDF

Continuous Measurements of Aromatic VOCs in a Mid-eastern Region of Seoul during Winter 2002/2003 (방향족 휘발성 유기화합물의 겨울철 연속 관측 연구)

  • 최여진;오상인;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.491-502
    • /
    • 2003
  • In the present work, the distribution characteristics of ambient volatile organic compounds (VOCs) were investigated at high temporal resolution from a monitoring station located in a mid-eastern area of Seoul. A total number of 587 samples were collected during December 2002 to January 2003. The measurements of VOC were conducted by a combination of on-line air sampling and thermal desorption unit (TDU) coupled with capillary GC/FID analysis. A total of five aromatic compounds (BTEX: benzene, toluene, ethylbenzene, m, p-xylene, and o-xylene) were measured routinely at hourly intervals during the whole study period. The mean concentrations of BTEX measured in our study period were found in the order: toluene (8.99 $\pm$5.38 ppb) > benzene (0.92$\pm$0.52 ppb) > m, p-xylene (0.51$\pm$0.34 ppb) > 0- xylene (0.48$\pm$0.35 ppb) > ethyl benzene (0.43$\pm$ 0.32 ppb). The BTEX concentrations were generally higher during the daytime than the nighttime, exhibiting certain patterns on a weekly basis. Results of our analysis indicate that the unusually high concentrations of toluene, while showing good correlations with other VOCs, can be a good indicator of air pollution in the study area.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

Development of Portable Gas Chromatography / Photoionization Detector System (휴대용 기체 크로마토그래피 / 광이온화 검출기 시스템의 개발)

  • Kim, Man Gu;Sim, Ji Hui;Lee, Dong Su;Lee, Yong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.151-159
    • /
    • 1994
  • The portable gas chromatography system was developed which was consisted of ambient vapor sampler(AVS), short capillary column(3 m long, 0.32 mm i.d. GC(SCCGC), photoionization detector (PID) and vacuum pump which was operated at subambient pressure. The seletion of capillary column was based on the theoretical calculation from Golay equation. The pressure ratio of column inlet and outlet appropriated between 1.03 and 1.2 in the system. The available column flow were 0.87∼4.63 ml/min at the pressure ratios. The AVS consisted of three concentric tubes and enables rapid, repetitive introduction of vapor samples directly into capillary column and showed good reproducibility. The subambient column outlet pressure with PID resulted in a significant increase in the optimum column flow, permitting rapid analysis. The baseline separation of m-xylene and o-xylene was able to within 40 second with the system. Parameters affecting the column resolving power were sampling duration, column length and diameter, and the pressure ratio. Effects of these parameters were investigated using bezene derivative compounds.

  • PDF

Estimation and Analysis of VOCs Emissions from Painting and Printing Facilities in Industrial Complexes of Gwangju (광주지역 산업단지 도장·인쇄시설의 휘발성유기화합물 배출 특성 평가)

  • Kim, Seung-Ho;Seo, Dong-Ju;Kim, Ha-Ram;Park, Jin-Hwan;Lee, Ki-Won;Bae, Seok-Jin;Song, Hyeong-Myeong
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.479-494
    • /
    • 2020
  • This study analyses the characteristics of volatile organic compounds (VOCs) emissions from the painting and printing facilities, as well as ambient VOCs at industrial complexes in Gwangju. The major components of VOCs emissions from painting facilities were toluene, acetone, 2-butanone, ethyl acetate, ethyl benzene, o-xylene and m,p-xylene. The printing facilities mostly emitted ethyl acetate, 2-butanone, acetone and toluene. Aromatics (49.9%) and oxygenated VOCs (43.6%) were dominant in painting facilities, while oxygenated VOCs (92.7%) were the largest group in printing facilities. The total hydrocarbon concentration (THC) in printing facilities was approximately six times higher than in the painting facilities. The painting and printing facilities use many solvents. Their THC concentrations differed considerably depending on the type of prevention facilities. To reduce THC, it is necessary to improve the prevention facilities and operating conditions. The dominant species of ambient VOCs in industrial complexes were investigated with toluene, ethyl acetate, 2-butanone, ethyl benzene, m,p-xylene, butyl acetate, o-xylene, hexane and acetone. Factor analysis of ambient VOCs showed that the main sources of the VOCs were organic solvents used in painting, coating, and printing, as well as automobile emissions.

Effect of Bioluminescence Stimulating Agent of the Genetically Engineered Strain KG1206 on the Monitoring of the Petroleum Hydrocarbon Contaminated Groundwater Samples (발광유전자 재조합 균주 활성 촉진 조건이 석유계 탄화수소 오염지하수 모니터링에 미치는 영향)

  • Ko, Kyung-Seok;Kong, In-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • This paper describes the application of bioluminescence stimulating agents on a genetically engineered microorganism, Pseudomonas putida mt-2 KG1206, to monitor toluene analogs using in groundwater samples from petroleum hydrocarbon contaminated sites. The maximum bioluminescent response with pure chemicals followed in the order: m-methyl benzyl alchohol > m-toluate > toluene > m-xylene > benzoate > p-xylene > o-xylene. Generally, the bioluminescence production of strain mixed with groundwater samples was dependent on the contaminated total inducer concentrations. However, few samples showed opposite results, where these phenomena may be caused by the complexicity of environmental samples. Two chemicals, SL(sodium lactate) and KNO$_3$, were tested to determine a better bioluminescence stimulant. Both chemicals stimulate the bioluminescence activity of strain KG1206, however, a slightly high bioluminescence was observed with nitrogen chemical. This selected stimulant was then tested on samples collected from contaminated groundwater samples. The bioluminescence activity of all samples mixed with the strain was stimulated with KNO$_3$ amendment. This suggests that the low bioluminescence activity exhibited by the environmental groundwater samples can be stimulated by amending the culture with a proper agent, such as nitrogen compound. These findings would be useful, especially, when strain was used to monitor the groundwater samples contaminated with low inducer contaminants. Overall, the results of this study found the ability of bioluminescence producing bacteria to biosensor a specific group of environmental contaminants, and suggest the potential for more efficient preliminary application of this engineered strain in a field-ready bioassay.

Evaluation of Mixed Organic Solvent Exposures in Painting Plants (도료 제조업 근로자들의 복합유기용제 폭로농도에 관한 연구)

  • Choi, Ho Chun;Oh, Doe-Suk;Oh, Se-Min;Chung, Kyou-Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.177-187
    • /
    • 1993
  • The exposure levels of mixed organic solvents for 66 exposed workers in six paint manufacturing plants were evaluated. In 66 exposed workers and 30 control subjects, we also determined the concentrations of toluene and xylene metabolites, hippuric acid, ($o^-$, $m^-$, and $p^-$)methylhippuric acid. The results were as follow ; 1. Seven organic compounds, which on averge accounted for approximately 90% of the identified mass in each painting plants air samples, were selected for quantification : methyl ethyl ketone, ethyl acetate, methyl isobutyl ketone, toluene, butyl acetate, ethyl benzene, ($o^-$, $m^-$, $p^-$)xylene. 2. The average mixed organic solvent exposure levels in 66 points with workplce were 3.8ppm of MEK, 12.2ppm of ethyl acetate, 4.0ppm of MIBK, 28.7ppm of toluene, 3.8ppm of butyl acetate, 10.2ppm of ethyl benzene, 14.6ppm of xylene, respectively. 3. For the total 66 points with workplace, the rate of them of which mixed solvents in air was exceeded th TLV of 1.0 were obtained for 23%(15/66 point). 4. The concentrations of hippuric acid in urine of exposed group and control were $0.94{\pm}0.65g/g$ of creatinine, $0.16{\pm}0.11g/g$ of creatinine, respectively. 5. There was a linear correlation between the end shift hippuric acid acid levels in urine and exposed toluene in air : y=0.02079X+494.2, r=0.6488, n=55 y:hippuric acid in urine(mg/g of creatinine), x:toluene levels in air(ppb) Toluene levels of 100ppm in air have been caculated to hippuric acid of 2.57g/g of creatinine in urine. 6. There was a linear correlation between the end shift methylhippuric acid acid levels in urine and exposed xylene in air : y=0.01664X+31.6, r=0.7264, n=55 y:methylhippuric acid in urine(mg/g of crea.), x:xylene levels in air(ppb) Xylene levels of 100ppm in air have been caculated to methylhippuric acid of 1.69g/g of creatinine in urine.

  • PDF

Preparation of Porous SiC by Freeze Drying of Polycarbosilane Emulsion (폴리카보실란 에멀젼의 동결건조를 이용한 다공체 SiC 제조)

  • Hwang, Yeon
    • Korean Journal of Materials Research
    • /
    • v.26 no.6
    • /
    • pp.320-324
    • /
    • 2016
  • Porous SiC beads were prepared by freeze-drying a polycarbosilane (PCS) emulsion. The water-in-oil (w/o) emulsion, which was composed of water, PCS dissolved p-xylene, and sodium xylenesulfonate (SXS) as an emulsifier, was frozen by dropping it onto a liquid $N_2$ bath; this process resulted in 1~2 mm sized beads. Beads were cured at $200^{\circ}C$ for 1 h in air and heat-treated at $800^{\circ}C$ and $1400^{\circ}C$ for 1 h in an Ar gas flow. Two types of pores, lamella-shaped and spherical pores, were observed. Lamellar-shaped pores were found to develop during the freezing of the xylene solvent. Water droplets in the w/o emulsion were changed into spherical pores under freeze-drying. At $1400^{\circ}C$ of heat-treatment, porous SiC was synthesized with a low level of impurities.

A Study on the Characteristics of Flammability for Organic Solvents of Three Component Systems (3성분계 유기용제의 인화특성에 관한 연구)

  • 임우섭;목연수;최재욱;최일곤;하동명;조태제
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.120-126
    • /
    • 1999
  • This study was accomplished by measuring the lower and upper flash point with air blowing method and grasping the characteristics of flammability for the three component systems, which are made up of the Benzene-Toluene-o-Xylene and Methylethylketone-Toluene-o-Xylene. These three component systems are widely used in the various industrial fields together with the development of industry. The results are as follows ; 1 ) Isothermal line is plotted on the triangular diagram for flash points determined in each solutions. From this line, the mixed compositions which indicated the same lower and upper flash points in each different composition could be read on this diagram, if the composition of mixtures are known. 2) Lower and upper explosion limits obtained from the flash points determined for the three component solution are compared with the value calculated from Le Chatelier's law. Especially the lower explosion limits are in a good agreement with the calculated values.

  • PDF