• Title/Summary/Keyword: non-testing methods

Search Result 489, Processing Time 0.023 seconds

Study of Boiler Tube Micro Crack Detection Ability by Metal Magnetic Memory (금속 자기기억법 활용 보일러 튜브의 미소 결함 검출력 연구)

  • Jungseok, Seo;Joohong, Myong;Jiye, Bang;Gyejo, Jung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.93-96
    • /
    • 2022
  • The boiler tubes of thermal power plants are exposed to harsh environment of high temperature and high pressure, and the deterioration state of materials rapidly increases. In particular, parent material and welds of the materials used are subjected to a temperature change and various constraints, resulting in deformation and its growth, resulting in frequent leakage accidents caused by tube failure. The power plant checks the integrity of boiler tubes through non-destructive testing as it may act as huge costs loss and limitation of power supply during power station shutdown period due to boiler tube leakage. However, the current non-destructive testing is extremely limited in the field to detect micro cracks. In this study, the ability of metal magnetic memory technique to detect flaws of size that are difficult to inspect by the visual or general non-destructive methods was verified in the early stage of their occurrence.

The Effects of Safety Training Involving Non-Destructive Testing Among Students at Specialized Vocational High Schools

  • Lim, YoungKhi;Han, Eun Ok;Choi, YoonSeok
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.98-105
    • /
    • 2017
  • Background: By examining the safety issues involved in on-site training sessions conducted at specialized vocational high schools, and by analyzing the effects of non-destructive testing (NDT) safety training, this study aims to contribute to ensuring the general safety of high school students. Materials and Methods: Students who expressed an interest in participation were surveyed regarding current NDT training practices, as well as NDT safety training. A total of 361 students from 4 schools participated in this study; 37.7% (136 students) were from the Seoul metropolitan area and 62.3% (225 students) were from other areas. Results and Discussion: Of the respondents, 2.2% (8 students) reported having engaged in NDT. As a result of safety training, statistically significant improvements were observed in most areas, except for individuals with previous NDT experience. The areas of improvement included safety awareness, acquisition of knowledge, subjective knowledge levels, objective knowledge levels, and adjustments to existing personal attitudes. Conclusion: Even at absolutely necessary observation-only training sessions, it is crucial that sufficient safety training and additional safety measures be adequately provided.

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

Reliability of Stool Antigen Tests: Investigation of the Diagnostic Value of a New Immunochromatographic Helicobacter pylori Approach in Dyspeptic Patients

  • Korkmaz, Huseyin;Findik, Duygu;Ugurluoglu, Ceyha;Terzi, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.657-660
    • /
    • 2015
  • Background: A diagnosis of H. pylori infection can be made by invasive or non-invasive methods. Several noninvasive diagnostic tests based on the detection of H. pylori stool antigen (HpSA) have been developed. The Genx H. pylori stool antigen card test is a new rapid, non-invasive test that is based on monoclonal immunochromatographic assay. The aim of this study was to determine its sensitivity, specificity, and diagnostic accuracy for diagnosing H. pylori infection in adult patients. Materials and Methods: A total of 162 patients were included in the study. A gastric biopsy was collected for histopathology and rapid urease testing. Stool specimens for HpSA testing were also collected. Patients were considered H. pylori positive if two invasive tests (histological and rapid urease tests) were positive. Results: Using the reference test, 50.6% of the samples were positive for H. pylori infection. The Genx H. pylori antigen test was positive in 19.7% of patients. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the Genx H. pylori antigen test were 51.6%, 96.0%, 88.8%, 76.1%, and 79.0%, respectively. Conclusions: The Genx H. pylori stool antigen card test is a new non-invasive method that is fast and simple to perform but provides less reliable results.

RPS Periodic Testing Method for Reliability and Availability (신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발)

  • Park, Joo-Hyun;Lee, Dong-Young;Lee, Seong-Jin;Song, Deok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

PAUT-based defect detection method for submarine pressure hulls

  • Jung, Min-jae;Park, Byeong-cheol;Bae, Jeong-hoon;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.2
    • /
    • pp.153-169
    • /
    • 2018
  • A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT) is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT) to detect surface defects and Ultrasonic Testing (UT) and Radiography Testing (RT) to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT) method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size.

Errors of Antibiotic Susceptibility Testing from Automated and Manual Systems in Clinical Isolates of Acinetobacter baumannii

  • Sung, Ji Youn;Oh, Ji-Eun;Kim, Eun Sun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.1
    • /
    • pp.21-25
    • /
    • 2013
  • Acinetobacter baumannii is an aerobic, gram-negative and glucose-non-fermenting bacterium, which has emerged as a serious opportunistic pathogen. Many clinical microbiology laboratories use the Vitek 2 system for the routine antimicrobial susceptibility testing process, including testing on A. baumannii isolates. However, in case of amikacin, it is now recommended to perform additional antimicrobial susceptibility testing for A. baumannii strains due to the relatively lower minimum inhibitory concentration (MIC) in the Vitek 2 system compared to conventional reference methods. In our study, we assessed MIC for amikacin susceptibility testing of A. baumannii isolates in the Vitek 2 system, the agar dilution, Etest, and disk diffusion method. We collected 40 gentamicin-resistant, A. baumannii strains (amikacin MIC by Vitek 2:${\leq}2{\mu}g/mL$, 2 isolates; $4{\mu}g/mL$, 34 isolates; $8{\mu}g/mL$, 4 isolates) from a University hospital and compared the Vitek 2 system to other reference methods for testing susceptibility to amikacin. The Vitek 2 system showed major errors in all of the 40 isolates, yielding a low MIC. The results of our study strongly suggested that the Vitek 2 system was not a reliable method to test the MICs of gentamicin; ranging from ${\geq}16{\mu}g/mL$ for amikacin susceptibility. Other tests, such as agar dilution, Etest, or disk diffusion methods, should be paralleled to determine the MIC of amikacin in A. baumannii.

  • PDF

Evaluation of surface treatment methods on the bond strength of veneer ceramic to the zirconia core (지르코니아 코어와 전장용 세라믹의 결합 강도에 대한 표면 처리 방법 평가)

  • Lee, Gwang-Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.213-219
    • /
    • 2020
  • Purpose: This study aimed to identify the impact of physical surface roughing with a polishing tool onto the pre-sintering yttria-stabilized tetragonal zirconia polycrystals (TZP) core and liner treatment for chemical bonding on the bond strength of TZP core and veneering ceramic. Methods: Overall, 80 specimens were classified into two groups (non-liner, NL; and usingliner, UL ) depending on the use of liner, and these two groups were then subclassified into four groups depending on the polishing tool used. (1) Non-liner groups: NS, non-liner+stone point; NC, non-liner+carbide bur; NP, non-liner+paper cone point; NT, non-liner+silicon point. (2) Using-liner groups: US, using-liner+stone point; UC, using-liner+carbide bur; UP, usingliner+paper cone point; UT, using-liner+silicon point. The pre-sintering surface roughing values and shapes were observed, and after burning up the veneering ceramic, the shear bond strength was measured using a universal testing machine. For significance testing, a one-way analysis of variance and Tukey's multiple comparison test were conducted. An optical microscope was used to observe the fracture plane, and the following results were obtained. Results: Surface roughness NP (4.09±0.51 ㎛) represented a higher value than other groups (p<0.001). In shear bond strength, NS (35.21±1.44 MPa) of the NL group showed the highest bond strength (p<0.001). The UL group did not show a statistically significant difference between groups (p=0.612). Conclusion: Our study findings reveal that the bond strength of TZP core and veneering ceramic was improved by pre-sintering physical surface treatment than by chemical bonding with liner surface treatment.

Effect of non-thermal plasma on the shear bond strength of resin cements to Polyetherketoneketone (PEKK)

  • Labriaga, Wilmart;Song, So-Yeon;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.6
    • /
    • pp.408-414
    • /
    • 2018
  • PURPOSE. This study aimed to assess the effect of non-thermal plasma on the shear bond strength of resin cements to polyetherketoneketone (PEKK) in comparison to other surface treatment methods. MATERIALS AND METHODS. Eighty PEKK discs were subjected to different surface treatments: (1) Untreated (UT); (2) Non-thermal plasma (NTP); (3) Sandblasting with $50{\mu}m$ $Al_2O_3$ particles (SB); and (4) Sandblasting + Non-thermal plasma (SB+NTP). After each surface treatment, the contact angle was measured. Surface conditioning with Visio.Link was applied in all groups after pre-treatment. RelyX Unicem resin cement was bonded onto the PEKK specimens. After fabrication of the specimens, half of each group (n=10) was initially tested, while the other half was subjected to thermocycling ($5^{\circ}C$ to $55^{\circ}C$ at 10,000 cycles). Shear bond strength (SBS) testing was performed using a universal testing machine, and failure modes were assessed using stereomicroscopy. The SBS results were analyzed statistically using one-way ANOVA followed by Tukey's post hoc test. Independent t-test was used to examine the effect of thermocycling (P<.05). RESULTS. The highest SBS values with or without thermocycling were observed with PEKK specimens that were treated with SB+NTP followed by the SB group. The lowest SBS results were observed in the UT groups. CONCLUSION. The shear bond strength between PEKK and resin cements was improved using non-thermal plasma treatment in combination with sandblasting.

Pulmonary Tuberculosis Diagnosis: Where We Are?

  • Leylabadlo, Hamed Ebrahimzadeh;Kafil, Hossein Samadi;Yousefi, Mehdi;Aghazadeh, Mohammad;Asgharzadeh, Mohammad
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.3
    • /
    • pp.134-142
    • /
    • 2016
  • In recent years, in spite of medical advancement, tuberculosis (TB) remains a worldwide health problem. Although many laboratory methods have been developed to expedite the diagnosis of TB, delays in diagnosis remain a major problem in the clinical practice. Because of the slow growth rate of the causative agent Mycobacterium tuberculosis, isolation, identification, and drug susceptibility testing of this organism and other clinically important mycobacteria can take several weeks or longer. During the past several years, many methods have been developed for direct detection, species identification, and drug susceptibility testing of TB. A good understanding of the effectiveness and practical limitations of these methods is important to improve diagnosis. This review summarizes the currently-used advances in non-molecular and molecular diagnostics.