• 제목/요약/키워드: noise measuring method

검색결과 483건 처리시간 0.041초

다구찌 방법을 이용한 A1 배선덕트의 스위칭 유도노이즈 특성에 관한 연구 (-A Study on the Switching Induction Noise Characteristic of A1 wiring Duct Using Taguchi Method-)

  • 홍석묵;박명규
    • 대한안전경영과학회지
    • /
    • 제5권2호
    • /
    • pp.199-214
    • /
    • 2003
  • With the progress of industrial technology, industrial machinery and home appliances have multi-function and high performances by the electronic control technology. Various results are given from the measuring switching induction noise according to environmental condition and its effects cannot be predicted accurately. Therefore, the output results should be analyzed and applied to practical work. To minimize the false operation, Taguchi Method used to solve the quality problem is adopted to analyze the characteristics within the constrained measuring level.

항공기 소음자동측정망 자료를 이용한 소음평가단위와 WECPNL과의 상관관계 비교 연구 (A correlation comparative method with noise assessment unit and WECPNL that use aircraft noise automatic measuring system)

  • 전형준;장서일;이기정
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.296-299
    • /
    • 2006
  • This study is about correlation between WECPNL and other units such as NNI, Leq and Ldn for aircraft noise that ere measured by automatic measuring system networks for grasping the effect of aircraft noise and investigated the aircraft noise level from 2004 to 2005 nearby 10 airports in Korea. It is very important to find the relationship among the various noise units, because exchange between the results of many other nation's study can improve the assessment and mitigation study of the aircraft noise. Correlation between WECPNL and M is better than one between WECPNL and Leq and between WECPNL and Ldn, because WECPNL and NNI are based on the PNL.

  • PDF

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • 제4권1호
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.

반무향실내에서의 가속 주행 소음 예측 방법 (Passby Noise Prediction in Semi-anechoic Chamber)

  • 박순홍;김양한;고병식
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.162-172
    • /
    • 1997
  • We investigated passby noise measurement method in a small-sized semi-anechoic chamber satisfying the American based SAE J1470 Recommended Practice to facilitate the measurements. We have tired two passby noise prediction methods. One is line array microphone method in which the free space sound field is decomposed into its eigenfunctions in the spherical coordinates and rearranged according to the order of the spherical Hankel function. However, due to the characteristics of the spherical Hankel function, it is impossible to distinguish the function's characteristics according to the order in farfield. Consequently it can be applied in the transient region of the nearfield and the farfield. The other method is nearfield acoustic holography(NAH). Although measuring hologram for the several operational engine speeds by conventional scanning method is time-consuming work, we can greatly reduce the measuring time by selecting the appropriate engine speed through preexperimental knowledge. To verify this method we experimented with the outdoor passby noise measurements and the passby noise prediction in the small-sized semi-anechoic chamber for the identical passenger vehicle and obtained reasonable and acceptable results.

  • PDF

ISO 방법론 및 1:10 축소잔향실을 이용한 확산률 측정 (Measuring Scattering Coefficient in 1:10 Reverberation Chamber Using the ISO Method)

  • 전진용;이병권;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.252-256
    • /
    • 2001
  • Scattering of surface materials has been known as one of the most important aspects in evaluating the acoustics of concert halls are designed. One of the methods that can reduce the errors in estimating the reverberation time and other acoustic parameters through computer modeling is to calculate scattering coefficient of surface materials. However. so far, no objective and reliable methods measuring scattering coefficient has been suggested. In this situation, ISO has suggested the method of measuring the random-incidence scattering coefficient on surfaces in diffuse field, whereas AES has introduced a method on directional-incidence in free field. In this study, the scattering coefficients of five kinds of hemispheres (1.5, 2.0. 2.5. 3.0. 3.5cm) were measured by using the ISO method in 1:10 reverberation chamber. It was found that 3.0cm hemisphere has the highest scattering coefficient satisfying 95% reliability.

  • PDF

변위응답의 측정으로부터 변형률응답을 예측하는 방법의 특성 (Characteristics of the Method to Predict Strain Responses from the Measurements of Displacement Responses)

  • 이건명;고재흥
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.844-848
    • /
    • 2005
  • A method to predict the strain responses from the measurements of displacement responses is considered. The method uses a transformation matrix which is composed of a displacement modal matrix and a strain modal matrix. The method can predict strains at points where displacements are not measured as well as at displacement measuring points. One of the drawbacks of the strain prediction method is that the displacement responses must be measured at many points on a structure simultaneously. This difficulty can be overcome by measuring the FRFs between displacements at a reference point and other point in sequence with a two channel measuring equipment This procedure is based on the assumption that the characteristics of excitation applied to the structure do not vary with time.

  • PDF

고압 전기설비 부분방전시험을 위한 노이즈 저감방안 (A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery)

  • 이영준;박광하;최형주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF

DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축 (Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor)

  • 김경서
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

공동주택 욕실 급수소음의 현장 측정방법 (Field Measurements on Noise Emission from Water Supply Installations in Bathroom of Apartment House)

  • 정갑철;국찬;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.341-344
    • /
    • 2005
  • The method of measurement for field tests on noise emission from water supply installations in bathroom of apartment house. This part of standard gives detailed descriptions for Held tests on noise emission from water supply installations in bathroom, bed room and living room of apartment house. Noise emission affect from working pressure and quantity of flow. The measuring position have to investigated measuring for emission noise.

  • PDF

온라인 변압기 부분방전 측정기법 적용 (An Application of the On Line Partial Discharge Measurement Method in Transformer)

  • 권동진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF