• 제목/요약/키워드: noise barrier performance

검색결과 91건 처리시간 0.023초

예측식을 이용한 철도방음벽의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Noise Reduction for Railway Noise Barrier using Prediction Equation)

  • 조준호;고효인
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.553-561
    • /
    • 2010
  • Railway noise barrier is generally used with welding of joint rail for railway noise reduction in our country. In this study, method for performance evaluation of railway noise barrier using insertion loss was suggested in case of without having noise measurement results before barrier installation. For this, railway noise measurements were performed in commercial high-speed railway site which has railway noise barrier. As a noise level before noise barrier installation, predicted noise level were used. From this method the performance evaluation for railway noise barrier were performed accurately and efficiently.

Effect of noise barrier on aerodynamic performance of high-speed train in crosswind

  • Zhao, Hai;Zhai, Wanming;Chen, Zaigang
    • Wind and Structures
    • /
    • 제20권4호
    • /
    • pp.509-525
    • /
    • 2015
  • A three-dimensional aerodynamic model and a vehicle dynamics model are established to investigate the effect of noise barrier on the dynamic performance of a high-speed train running on an embankment in crosswind in this paper. Based on the developed model, flow structures around the train with and without noise barrier are compared. Effect of the noise barrier height on the train dynamic performance is studied. Then, comparisons between the dynamic performance indexes of the train running on the windward track and on the leeward track are made. The calculated results show that the noise barrier has significant effects on the structure of the flow field around the train in crosswind and thus on the dynamic performance of the high-speed train. The dynamic performance of the train on the windward track is better than that on the leeward track. In addition, various heights of the noise barrier will have different effects on the train dynamic performance. The dynamic performance indexes keep decreasing with the increase of the noise barrier height before the height reaches a certain value, while these indexes have an inverse trend when the height is above this value. These results suggest that optimization on the noise barrier height is possible and demonstrate that the designed noise barrier height of the existing China Railway High-speed line analysed in this article is reasonable from the view point of the flow field structure and train dynamic performance although the noise barrier is always designed based on the noise-related standard.

합성수지 방음벽의 성능예측 및 평가 (Performance prediction and measurement of the barrier)

  • 박진규;김관주;정환익;김상헌;최상석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.718-723
    • /
    • 2004
  • The insertion loss of a noise barrier comes from the effects of diffraction, transmission loss, absorption coefficient and attenuation by direct propagation. The noise level after the noise barrier, differs reatly from the diffraction on the upper part of the barrier. Maekawa, furze and Anderson presented a empirical formula for calculating the diffraction of a semi infinte screen shaped noise barrier. In this syudy, Noise reduction performance software was developed for the proper design and assessment of new plastic barrier . Predicted sound pressure level from using the software is compared with the site-measurement results to verify the noise reduction performance and feasibility of prediction software for insertion loss of noise barrier.

  • PDF

흡음형 방음벽의 내부 구성에 따른 흡음특성 (Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier)

  • 박진규;김상헌;김관주;박희준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

흡음형 방음벽의 성능향상에 관한 연구 (A Study on Performance Improvement of Sound Absorbing Noise Barrier)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.849-854
    • /
    • 2001
  • A study on performance of the sound absorbing noise barrier is presented. Noise barrier of sound absorbing type is composed of the front panel, sound absorbing material, and back panel. For allowing sound path, front panel is usually perforated. The performance of the noise barrier is governed by the opening ratio of the perforated panel, sound absorption coefficient of the sound absorbing material. In this study, the effects of the opening ratio, diameter of the hole, thickness of the sound absorbing material are investigated. It is found that the thickness of the sound absorbing material must be at least 50 mm to ensure the required minimum NRC value 0.70, and the opening ratio is greater than 0.2. It is shown that the thickness of the back panel is crucial in providing required STL (Sound Transmission Loss) value. The performance of the developed noise barrier is measured, where its sound absorbing coefficient and sound transmission loss satisfy the criteria.

  • PDF

방음벽 종류별 반사음 저감효과 및 회절효과에 관한 실험적 연구 (An Experimental Study on the Reduction Effect of Reflected Sound and Diffraction Effect by Types of Noise Barrier)

  • 김흥식
    • 소음진동
    • /
    • 제6권2호
    • /
    • pp.245-251
    • /
    • 1996
  • This study is to suggest the improved noise barrier which is harmonized with surrounding landscape and maintained the similar reduction of reflected sound and diffraction effects in comparison with the aluminum noise barrier of absorbing type which is formed a great majority in Korea. In this study the two improved models of noise barrier(Diffuse and Disperse type) were designed and compared with the noise barriers of absorbing type in the acoustics performance (the reduction of reflected sound and diffraction effects) through the field and full-scale experimental measurement. As these two models have the same acoustic performance as the noise barrier of aluminum absorbing type, it is suggested that these models can be applied to the improved noise barrier as an alteration of aluminum absorbing type barrier.

  • PDF

방음벽 상단의 소음감소기 성능 시험 (Performance Test of Noise Reducers Installed on Noise Barrier)

  • 강대준;이재원;구진회
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.388-391
    • /
    • 2006
  • The use of noise barrier is being increased to reduce the environmental noise in these days. Also, many noise reducers installed at the top of noise barrier are developed for improving the performance of noise reduction. So we evaluate the performance of the noise reducers and compare the results. Results of the field tests show that the insertion loss due to the noise reducers is up to 10.6 dB.

  • PDF

능동방음벽 시스템의 제어 음원 위치 선정에 미치는 최적화 기법 성능 비교 연구 (A Study on the Performance Comparison of Optimization Techniques on the Selection of Control Source Positions in an Active Noise Barrier System)

  • 임형진;백광현
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.911-917
    • /
    • 2005
  • There were many attempts to reduce noise behind the noise barrier using active control techniques. Omoto(1993) Shao(1997) and Yang(2001) tried to actively control the diffracted noise behind the barrier and main concerns were about the arrangement methods for the control sources. Baek (2004) tried to get better results using the simulated annealing method and the sequential searching technique. The main goal of this study is to develop and compare the performance of several optimization techniques including those mentioned above, hybrid version of simulated annealing and genetic algorithm for the optimal control source positions of active noise barrier system. The simulation results show fairly similar performance lot the small size of searching problem. However, as the number of control sources are increased, the performance of simulated annealing algorithm and genetic algorithm are better than the others. Simulations are also made to show the performance of the selected optimal control source positions not only at the receiver position but at the surrounding volume of the receiver position and plotted the noise reduction level in 3-D.

건설공사장 가설방음벽의 음향 특성 (Acoustic Properties of Temporary Noise Barriers on Construction Site)

  • 정진연;임정빈;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 2010
  • The noise by the construction activities is one of the main issues in Korea. To prevent the noise from construction site, construction company installs temporary noise barriers along the construction site boundary. Normally sound insulation performance ($R_w$) of the temporary noise barriers made by metal or plastic is between 18 and 31 dB and metallic noise barriers are around 5 dB higher than plastic noise barriers. Sound absorption performance (NRC) of the temporary noise barriers are between 0.20 and 0.59 so it's difficult to characterize their acoustic performance. In this study, it has founded that sound insulation performance of the temporary noise barrier has been improved about 3dB by stick the high density acoustic sheet and insertion loss of noise barrier is getting increased as the source and receiver approached the temporary noise barriers.

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level -)

  • 김철환;장태순;이기정;김동준;정태량;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF