• Title/Summary/Keyword: noise addition

Search Result 1,866, Processing Time 0.03 seconds

Noise Reduction Method and Sources of Cyclone for Vacuum Cleaner (청소기용 Cyclone 소음원 및 저감방법)

  • Lee, Jun-Hwa;Hong, Seung-Gee;Joo, Jae-Man;Oh, Sang-Kyong;Song, Hwa-Gyu;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.89-92
    • /
    • 2004
  • Cyclone is widely apoted in the vacuum cleaner, because of it's simple structure, the dust collection efficiency is high and its transparency feaure which can be shown to the customer. At past times, cyclone performance is represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, cyclone's pressure drop and noise is measured at the variation of the cyclone structure and the main sources of cyclone peak noise is found by experiments and numerical analysis. In addition, the structure for peak noise reduction is suggested and it is beneficial both pressure drop and noise reduction.

  • PDF

A Study on the Road Traffic Noise Effect Using a Noise Map - Development of Sihwa Multi Techno Valley - (소음지도를 이용한 도로교통소음에 관한 연구 - 시화멀티테크노밸리 개발사업을 중심으로 -)

  • Jeong, Jea-Hun;Kim, Heung-Man;Kwon, Woo-Taeg;Kim, Hyung-Chol
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.2
    • /
    • pp.89-97
    • /
    • 2009
  • Korean society is faced with various new problems arising from the development projects of new towns, industrial cities, large-scale residential complexes, etc. started from the 1970s. Particularly with the construction of residential and industrial complexes by the roadsides, they are openly exposed to road traffic noise and vibration. Thus, the objective of this study is to examine using noise maps how increasing traffic volume affects road traffic noise and what problems it causes in areas where new towns or complexes are constructed by development projects. According to the results of this study, in areas around the sites of development projects, the noise level increased by road traffic noise compared to that before development and was 1.16~6.92 times higher than the environmental noise standard, but measures to reduce road traffic noise was lukewarm. In addition, areas with soundproof facilities showed a noise level 1~3 step lower than other areas, and in individual buildings, the noise level on the side facing the road was 1~2 step higher than that on the rear side.

A Study on the Noise Reduction Technology for Air-Compressor (공기압축기 소음 저감 기술에 관한 연구)

  • Kim, Bong-Gi;Kim, Jae-Seung;Kim, Hyeon-Sil;Gang, Hyeon-Ju;Kim, Sang-Ryeol
    • 연구논문집
    • /
    • s.33
    • /
    • pp.39-51
    • /
    • 2003
  • This paper deals with the noise measurement and evaluation method of a reciprocating air-compressor and its noise reduction. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving piston, and flow-induced noise which are caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends. As a result, it can be found that main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, engineering plastics are used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings in the cylinder head. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10 dB.

  • PDF

Fast non-local means noise reduction algorithm with acceleration function for improvement of image quality in gamma camera system: A phantom study

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.719-722
    • /
    • 2019
  • Gamma-ray images generally suffer from a lot of noise because of low photon detection in the gamma camera system. The purpose of this study is to improve the image quality in gamma-ray images using a gamma camera system with a fast nonlocal means (FNLM) noise reduction algorithm with an acceleration function. The designed FNLM algorithm is based on local region considerations, including the Euclidean distance in the gamma-ray image and use of the encoded information. To evaluate the noise characteristics, the normalized noise power spectrum (NNPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV) were used. According to the NNPS result, the lowest values can be obtained using the FNLM noise reduction algorithm. In addition, when the conventional methods and the FNLM noise reduction algorithm were compared, the average CNR and COV using the proposed algorithm were approximately 2.23 and 7.95 times better than those of the noisy image, respectively. In particular, the image-processing time of the FNLM noise reduction algorithm can achieve the fastest time compared with conventional noise reduction methods. The results of the image qualities related to noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in a gamma camera system.

Diagnostics and Prognostics Based on Adaptive Time-Frequency Feature Discrimination

  • Oh, Jae-Hyuk;Kim, Chang-Gu;Cho, Young-Man
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1537-1548
    • /
    • 2004
  • This paper presents a novel diagnostic technique for monitoring the system conditions and detecting failure modes and precursors based on wavelet-packet analysis of external noise/vibration measurements. The capability is based on extracting relevant features of noise/vibration data that best discriminate systems with different noise/vibration signatures by analyzing external measurements of noise/vibration in the time-frequency domain. By virtue of their localized nature both in time and frequency, the identified features help to reveal faults at the level of components in a mechanical system in addition to the existence of certain faults. A prima-facie case is made via application of the proposed approach to fault detection in scroll and rotary compressors, although the methods and algorithms are very general in nature. The proposed technique has successfully identified the existence of specific faults in the scroll and rotary compressors. In addition, its capability of tracking the severity of specific faults in the rotary compressors indicates that the technique has a potential to be used as a prognostic tool.

Structure Vibration Analysis and Active Noise Control of Power Transformer (전력용변압기의 구조진동해석 및 능동소음제어)

  • Jeong, Yun-Mi;Choi, Eun-Ji;Kim, Young-Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1771-1776
    • /
    • 2013
  • Most cases of power transformer failure are caused by physical factors linked to the transient vibrations of multiple 120Hz combinations. In addition, the noise generated in the transformer from this vibration not only directly contributes to the worsening of the work environment but also causes psychological stress, resulting in the worsening of the workers efficiency and of the living environment of the inhabitants around the power plant. Thus, to remedy these problems, the mechanical-excitation forces working on a power transformer were categorized in this study, and the mechanical-damage mechanism was identified through the vibration transfer paths acting on machines or structures. In addition, a study on active noise cancellation in a transformer using the FXLMS algorithm was conducted to develop a system that is capable of multiple-sound/channel control, which resulted in the active noise reduction effect when applied on the field.

An Improvement in Adaptive Estimation for a Tracking System with Additive Measurement Impulse noise (충격성 잡음이 혼입되는 추적계통의 적응 추정 개선)

  • 윤현보;박희창
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.5
    • /
    • pp.519-526
    • /
    • 1987
  • An adaptive estimation system which operates propoerly in the environments corrupted by additive impulse noise in addition to the white Gaussian noise has been proposed. A feed forward loop is inserted into the adaptive estimator proposed by R. L. Moose for a system with an unknown measurement bias by which the improved adaptive estimator is processed successfully without the sum of the time varying weights being zero even when the measurement system is added impulue noise. Successfully processed adaptive estimator has been obtained under the large impulse noise in addition to randomly varying unknown biases condition by giving sufficient large value to the elements of discrete vector on the computer simulation.

  • PDF

Study on the Indoor Acoustic Field Analysis using the Blast Wave Model (폭발파 모델을 이용한 실내 음장 해석에 관한 연구)

  • Song, Kee-Hyeok;Kang, Woo-Ram;Lee, Duck-Joo;Kim, Young-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.142-150
    • /
    • 2015
  • A portable recoilless guided missile generates a strong back blast and impulsive noise at the nozzle when it launches. In the case of indoor operations, the hazard of the blast noise from a recoilless weapon increases due to limited indoor spaces. Also, the noise levels determine the operational feasibility of a weapon; therefore, it is important to predict the blast noise levels distribution in the indoor space in advance. In addition, computational fluid dynamics (CFD) method generally used for fluid related simulations, requires high computing cost and time to simulate the whole domains. The domain includes both blast wave region and large and various indoor space region. Therefore, an efficient method for predicting the far-field noise level within a short time should be developed. This paper describes an analysis model for predicting the indoor noise distributions by considering the shape effect of the building within a short time. A new developed blast wave model was implemented using the noise source. Additionally, noise reflections at the closed surfaces such as walls and noise transmissions at the opened surfaces such as windows and doors were considered in calculating the noise levels. The predicted noise levels were compared with the experimental data obtained from the indoor launch test to validate the reliability of program.

Structureborne Noise Transfer Analysis Using Pole Parameter Method for Resiliently Mounted Equipment (절점 해석 기법을 이용한 탄성지지 장비 시스템의 고체음 전달 해석)

  • Choi, Tae-Muk;Kim, Tae-Suk;Cho, Dae-Seung;Chung, Jung-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.398-402
    • /
    • 2005
  • Structureborne noise induced by shipboard equipment is one of the most significant noise source of ships and can be effectively reduced by resiliently mounting them. In this paper, the pole parameter method is investigated for estimating the structureborne noise reduction of resiliently mounted equipment. In addition, we suggest how to evaluate pole parameters from dimensional and material information of each component consisting of resiliently mounted equipment. To validate and discuss the proposed method numerical analysis for single and double resiliently mounted equipment systems using both pole parameter method and FEM have been done.

  • PDF

The Characteristics of HVAC Noise in Office Buildings (사무소 건물의 공조설비소음 특성)

  • Do, Young-Ju;Kim, Dong-Gyu;Kim, Heung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 1989
  • This study aims to provide the basic data useful in assessing indoor-noise and designing sound devices in office buildings of HVAC system. The measurements of HVAC noise were carried out in office room and mechanical room. The performance of absorptive chamber and side branch was also estimated in the office buildings which have HVAC noise problems. The results of experiments show that the NR value of indoor HVAC noise is rather higher than that of ISO recommendations at the frequencies below 500Hz. In addition, the results indicated that the absorptive chamber attenuates noise over broad band frequencies and side branch reduces noise at the special resonant frequency.

  • PDF