• 제목/요약/키워드: no-load power

검색결과 516건 처리시간 0.028초

직분식 CNG 엔진에서 연료 분사시기의 변화가 연소 및 출력 특성에 미치는 영향 (The Effect of Fuel Injection Timing on Combustion and Power Characteristics in a DI CNG Engine)

  • 강정호;윤수한;이중순;박종상;하종률
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.193-200
    • /
    • 2007
  • Natural gas is one of the most promising alternatives to gasoline and diesel fuels because of its lower harmful emissions, including $CO_2$, and high thermal efficiency. In particular, natural gas is seen as an alternative fuel for heavy-duty Diesel Engines because of the lower resulting emissions of PM, $CO_2$ and $NO_x$. Almost all CNG vehicles use the PFI-type Engine. However, PFI-type CNG Engines have a lower brake horse power, because of reduced volumetric efficiency and lower burning speed. This is a result of gaseous charge and the time losses increase as compared with the DI-type. This study was conducted to investigate the effect of injection conditions (early injection mode, late injection mode) on the combustion phenomena and performances in the or CNG Engine. A DI Diesel Engine with the same specifications used in a previous study was modified to a DI CNG Engine, and injection pressure was constantly kept at 60bar by a two-stage pressure-reducing type regulator. In this study, excess air ratios were varied from 1.0 to the lean limit, at the load conditions 50% throttle open rate and 1700rpm. The combustion characteristics of the or CNG Engine - such as in-cylinder pressure, indicated thermal efficiency, cycle-by-cycle variation, combustion duration and emissions - were investigated. Through this method, it was possible to verify that the combustion duration, the lean limit and the emissions were improved by control of injection timing and the stratified mixture conditions. And combustion duration is affected by not only excess air ratio, injection timing and position of piston but gas flow condition.

CNG엔진에서 합성가스 연료의 연소 및 배기 특성 평가 (Characteristics of Combustion and Emission for Synthetic Natural Gas in CNG Engine)

  • 이성원;임기훈;박철웅;최영;김창기
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.8-14
    • /
    • 2015
  • 합성가스(SNG)는 석탄 가스화를 통하여 얻어지는 가스연료로서, 고유가로 인한 천연가스가격 상승을 대비할 수 있는 대체연료 중의 하나로 주목받고 있다. 본 연구에서는 메탄 90.95%, 프로판 6.05%와 수소 3%의 조성비를 갖는 SNG연료 모사가스와 압축천연가스 (CNG)를 11리터 급 CNG 엔진에 적용하여 연소 및 배기 특성을 비교실험 하였다. 연료공급시스템, 분사시기 등 엔진의 연소제어인자를 일정하게 하고 전부하 운전조건에서 엔진회전수 변화에 따른 출력, 열효율, 연소 안정성 및 배기특성을 비교하였다. 1260rpm, 전부하 운전조건에서 노킹특성도 분석하였다. SNG 연료를 사용했을 때 출력 저하 없이 연소안정성이 향상되어 열효율이 증가하였다. 질소산화물($NO_x$)의 배출은 CNG연료의 경우에 비해 증가되었으나 이산화탄소($CO_2$)의 배출은 감소하였다. SNG 연료를 이용하여 운전할 경우 내노킹성이 향상되었다.

건물용 고체산화물연료전지 스택 안전성능평가 연구 (Study on safety performance evaluation of stationary SOFC stack)

  • 박태성;이은경;이승국
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.1-12
    • /
    • 2018
  • SOFC (Solid Oxide Fuel Cell) stack 안전성능 평가항목 및 평가절차 도출을 위하여 국내 외 연료전지 관련 규격들을 분석하였으며, 분석을 통해 도출된 시험항목으로 SOFC stack 안전성능 시험을 실시하였다. 시험에 사용된 SOFC stack은 (주)미코사(社)에서 제작된 음극 지지형 2 cell stack(활성면적: $110.25cm^2/cell$)이고, 평가장치는 자체 제작한 SOFC stack 안전성능 평가 장치를 사용하였다. 기밀성능 시험, 전류전압특성 시험, 정격출력 시험 및 부하변동 시험을 실시하였으며, 그 결과 해당 stack의 최대출력은 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 정격출력은 62.3 W(1.57 V, 40 A, $363mA/cm^2$)로 나타났으며 가스누출이 없음을 확인하였다. 또한, 부하변동에 대하여 2초 이내에 안정적으로 출력이 유지되는 것을 확인하였다. 이때 운전 온도 $750^{\circ}C$에서 최대부하(40 A) 및 최소부하(8 A)에서의 출력은 각 62 W와 16 W로 측정되었다. 본 연구를 통하여 고체산화물연료전지의 보급화와 안전한 사용 환경을 제공하는데 기여하고자 한다.

부하 변조 및 위상 보상 DGS 마이크로스트립 선로를 이용한 도허티 증폭기 (Doherty Amplifier Using Load Modulation and Phase Compensation DGS Micro-Strip Line)

  • 최흥재;임종식;정용채
    • 한국전자파학회논문지
    • /
    • 제16권8호
    • /
    • pp.815-824
    • /
    • 2005
  • 본 논문에서 우리는 새로운 방식의 IMT-2000 대역 DGS(Defected Ground Structure) 도허 티 증폭기를 제안하였다. 근본적으로 도허티 증폭기의 능동 로드-풀 회로 해석 기법은 이상적인 고조파 단락 상태를 가정한다. 그러나 기존의 논문에서는 대부분 이러한 이상적인 고조파 단락을 간과하고 있었다. 우리는 도허티 주 증폭기의 부하 변조 동작에 필수적인 출력단의 임피던스 변환 전송 선로와 보조 증폭기의 출력 임피던스 보정을 위한 오프셋 전송 선로에 DGS를 적용함으로써 이러한 가정을 만족시킴과 동시에 이득, 효율 그리고 최대 출력 전력을 개선하였으며, 선형성 개선과 상당한 크기 감소 효과도 얻을 수 있었다. 제안된 DGS 도허티 증폭기의 2차, 3차 고조파는 비교 대상으로 제작된 일반적인 도허티 증폭기에 비해 각각 44.92 dB, 23.77 dB 이상 차단되었다. 그 결과로서 얻어진 DGS 도허티 증폭기의 P1 dB는 0.42 dB 증가하였고 드레인 효율은 최대 $13.4\%,$ 이득은 0.33 dB 증가하였으며, WCDMA 1 FA 신호에 대한 ACPR 특성이 최대 5.4 dEc 개선되었다. 게다가 주 증폭기와 보조 증폭기 경로에서 각각 $90^{\circ}$ 전기각에 해당하는 길이를 줄일 수 있어 전체 회로의 크기를 상당히 줄일 수 있었다.

동력경운기의 경사지견인 및 주행특성에 관한 연구 (III)-동력경운의 경사지 견인성능- (Study on the Travel and Tractive Characteristics of the Two-Wheel Tractor on the General Slope Land(III)-Tractive Performance of Power Tiller-)

  • 송현갑;정창주
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.35-61
    • /
    • 1978
  • 동력경운깅가 일반 경사지에서 견인주행하는 경우 견인주행성능과 주행특성을 구명하기 위하여 토양의 종류 및 상태는 일정하게 하고 지면의 기하학적 조건과 견인주행속도 및 견인하중을 변수로 하여 외부동력전달계의 시점인 좌우차륜과 토양간에 발생하는 차륜구동력 및 굴름정항과 Engine에서 구동륜까지 내부전달계를 통하여 전달된 동력의 이론치와 실험치와의 부합여부를 검정하고 부가적으로 동력경운기가 경사지기계화의 동력기로써의 가능성여부와 문제점을 찾으려한다.

  • PDF

동력경운기의 경사지견인 및 주행특성에 관한 연구 (Ⅲ)-동력경운의 경사지 견인성능- (Study on the Travel and Tractive Characteristics of the Two-Wheel Tractor on the General Slope Land(Ⅲ)-Tractive Performance of Power Tiller-)

  • 송현갑;정창주
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.34-34
    • /
    • 1978
  • 동력경운깅가 일반 경사지에서 견인주행하는 경우 견인주행성능과 주행특성을 구명하기 위하여 토양의 종류 및 상태는 일정하게 하고 지면의 기하학적 조건과 견인주행속도 및 견인하중을 변수로 하여 외부동력전달계의 시점인 좌우차륜과 토양간에 발생하는 차륜구동력 및 굴름정항과 Engine에서 구동륜까지 내부전달계를 통하여 전달된 동력의 이론치와 실험치와의 부합여부를 검정하고 부가적으로 동력경운기가 경사지기계화의 동력기로써의 가능성여부와 문제점을 찾으려한다.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권4호
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현 (Implementation of the BLDC Motor Drive System using PFC converter and DTC)

  • 양오
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.62-70
    • /
    • 2007
  • 본 논문에서는 일정 토크영역에서 승압형 PFC 컨버터와 직접토크제어(DTC) 방법을 사용하여 BLDC 모터의 구동 시스템을 DSP(TMS320F2812)로 구현하였다. 기존의 6단계 PWM 전류제어와 달리 미리 정한 샘플시간 마다 간단한 look-up 표로부터 2상 도통 모드에 대한 인버터의 전압 상태 벡터를 설정함으로써 원하는 전류파형을 만들었으며 이로부터 기존의 전류제어기보다 훨씬 빠른 토크 응답특성을 얻을 수 있었다. 또한 BLDC 모터의 비 이상적인 사다리형 역기전력에 의해 발생되는 저주파 토크변동을 저감하기 위하여 위치 loop-up 표를 사용하였다. 아울러 역률을 보정하기 위해 승압형 PFC 컨버터를 구성하였고 이 때 전파 정류된 입력전압과 출력전압, 인덕터의 전류에 의해 평균전류모드 제어 방식으로 80 kHz마다 PWM 듀티(duty)가 조절 되도록 하였다. 이와 같이 복잡한 제어 알고리즘은 초고속 DSP의 출현으로 PFC와 DTC 알고리즘이 동시에 제어가 가능하며, 본 논문에서는 DTC 알고리즘을 구현할 때 DSP의 일반 범용의 출력포트를 사용하여 구현하였고 단지 PFC에서만 1개의 PWM을 사용하여 디지털 제어기를 구현하였다. 실험을 통해 DTC 알고리즘과 PFC 컨버터를 이용한 BLDC 모터 구동 시스템의 타당성과 효용성을 보였고, 실험결과로부터 PFC 컨버터를 사용하지 않았을 때는 역률이 약 0.77이었으나 PFC 컨버터를 사용하였을 때는 부하변동에 관계없이 약 0.9997로 크게 향상됨을 확인하였다.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

MW급 EGS 지열발전 상용화 기술개발사업의 추진 배경 및 계획 (Research Background and Plan of Enhanced Geothermal System Project for MW Power Generation in Korea)

  • 윤운상;송윤호;이태종;김광염;민기복;조용희;전종욱
    • 터널과지하공간
    • /
    • 제21권1호
    • /
    • pp.11-19
    • /
    • 2011
  • 지열에너지는 여러 신재생에너지원 중에서도 기저부하를 담당할 수 있는 중요한 자원으로 인식되고 있다. 국내에서도 천부지열을 이용한 지열냉난방은 효율 높은 신재생에너지 활용 사업으로 그 보급이 활성화 되어 있다. 반면, 전세계적으로 지열 발전 기술이 진일보하고, 그 시장이 크게 확대되고 있는 상황에서 아직까지 국내의 심부 지열을 이용한 지열 발전 기술은 낮은 단계에 머무르고 있다. 이러한 조건에서 2010년 12월에 국내 최초의 EGS(Enhanced Geothermal System) 지열 발전 상용화 기술 개발 과제가 착수되었다. 총 5개년의 기간으로 수행되는 이 과제는 2단계로 구분되어 진행될 계획이다. 처음 2년의 1단계에서는 3 km 심도에서 최소 $100^{\circ}C$의 지열저류층 온도를 확인하는 것을 주요 과제 내용으로 하여 지중 지열수 순환시스템의 설계가 이루어질 예정이다. 이후 3년을 통해 수행될 2단계에서는 5 km 심도의 생산정과 주입정 등 두 개의 지열발전정을 설치하고, 수리자극을 통하여 온도 $180^{\circ}C$의 지열저류층에서 유량 40 kg/s 이상의 지열수를 활용하는 MW급 지열발전소를 건립 운영하게 된다. 이 사업을 성공적으로 추진하기 위하여 현재 지질, 수리지질, 지구물리, 암석역학, 플랜트 엔지니어링 등 다양한 분야의 산학연 연구 기관 등이 망라되어 연구진을 구성한 상태이며, 이후 관심있는 여러 기관과 연구자들의 지원과 참여를 기대하고 있다.