• Title/Summary/Keyword: new material

Search Result 7,722, Processing Time 0.045 seconds

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

Establishment of Database System for Radiation Oncology (방사선 종양 자료관리 시스템 구축)

  • Kim, Dae-Sup;Lee, Chang-Ju;Yoo, Soon-Mi;Kim, Jong-Min;Lee, Woo-Seok;Kang, Tae-Young;Back, Geum-Mun;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.91-102
    • /
    • 2008
  • Purpose: To enlarge the efficiency of operation and establish a constituency for development of new radiotherapy treatment through database which is established by arranging and indexing radiotherapy related affairs in well organized manner to have easy access by the user. Materials and Methods: In this study, Access program provided by Microsoft (MS Office Access) was used to operate the data base. The data of radiation oncology was distinguished by a business logs and maintenance expenditure in addition to stock management of accessories with respect to affairs and machinery management. Data for education and research was distinguished by education material for department duties, user manual and related thesis depending upon its property. Registration of data was designed to have input form according to its subject and the information of data was designed to be inspected by making a report. Number of machine failure in addition to its respective repairing hours from machine maintenance expenditure in a period of January 2008 to April 2009 was analyzed with the result of initial system usage and one year after the usage. Results: Radiation oncology database system was accomplished by distinguishing work related and research related criteria. The data are arranged and collected according to its subjects and classes, and can be accessed by searching the required data through referring the descriptions from each criteria. 32.3% of total average time was reduced on analyzing repairing hours by acquiring number of machine failure in addition to its type in a period of January 2008 to April 2009 through machine maintenance expenditure. Conclusion: On distinguishing and indexing present and past data upon its subjective criteria through the database system for radiation oncology, the use of information can be easily accessed to enlarge the efficiency of operation, and in further, can be a constituency for improvement of work process by acquiring various information required for new radiotherapy treatment in real time.

  • PDF

Experimental Study on Effectiveness of Wave Reduction and Prevention Erosion of Nourishment Sand Using the Cell Group (Cell Group을 이용한 파랑저감 및 양빈사 유실방지에 관한 실험적 연구)

  • Park, Sang Kil;Park, Hong Bum;Kim, Young Hwan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.5
    • /
    • pp.269-277
    • /
    • 2017
  • Recently, a submerged breakwater has been installing to prevent the erosion of shoreline everywhere. Artificially submerged breakwater is made to minimize the loss of nourishment sand beach erosion. For this reason, it has been indiscriminately constructed submerged breakwater that is planned in the country throughout. However, maintenance purposes to keep the shoreline of the beach is a method that is quite a few problems. There are also disadvantages such as expensive construction costs, ocean space utilization, water pollution and shoreline modification. In addition, person of utilizing the space of the ocean leisure does not like that because of the disconnection of ocean space. The beaches such as Gwanganri are artificially supplying nourishment sand to maintain the beach. The flexible construction method refers to a structure that is installed as a flexible material instead of submerged breakwater to prevent the loss of nourishment sand. In order to develop a new method to mitigate shoreline erosion, this study was carried out a hydraulic model experiment by installing a cell group as an example of the flexible method. Namely, in order to prevent the loss of nourishment sand, we decided to develop a new method that can mitigate the degree of beaches erosion by using cell group instead of submerged breakwater. In the two dimensional fixed hydraulic experiment, was carried out the effect reducing of wave height and the rate of low reflection due to the installation of the cell group. In movable bed experiment, the capture rate of the nourishment sand and the erosion prevention rate of the nourishment sand was performed for stability of shoreline. Therefore, according to the results of the hydraulic tests, it was possible to maintain the stable beaches due to installing the cell group on the erosion beaches, due to the effect of reducing wave height, the low reflection, the erosion prevention rate of nourishment sand, the high capture rate of nourishment sand.

Experimental Performance Evaluation of Steel Mesh as Maintenance and Reinforcement Materials (Steel Mesh Cement Mortar의 보수⋅보강 성능 평가)

  • Kim, Yeon-Sang;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.50-58
    • /
    • 2014
  • Due to the cost burden of new construction, the necessity of repair and retrofitting of aged structures is sharply increasing as the domain of repair and retrofitting construction is expanding. Because of the necessity, new technologies for repair and retrofitting are continuously studied in Korea and foreign countries. Steel adhesive method, fiber reinforced plastic (FRP) surface adhesive method, and external prestressing method are used to perform the repair and retrofitting works in Korea. In order to consider a repair method using steel mesh reinforced cement mortar (SMCM), 3-point flexural member test was conducted considering repair area and layer number of SMCM. Five types of specimens including ordinary reinforced concrete (RC) specimen with dimensions of $1400{\times}500{\times}200$ (mm) were cast for testing the deflection measurement, a LVDT was installed at the top center of the specimens. Also, a steel strain gauge and a concrete strain gauge were placed at the center of the specimens. A steel strain gauge was also installed on the shear reinforcement. The 3 point flexural member test results showed that the maximum load of SMCM reinforced specimen was higher than that of basic RC specimen in all of the load-displacement curves. Also, the results showed that, when the whole lower part of the basic RC specimen was reinforced, the maximum load and strain were 1.18 and 1.37 times higher than that of the basic RC specimen, respectively. Each specimen showed a slightly different failure behavior where the difference of the results was caused by the difference in the adhesive level between SMCM and RC. Particularly, in SM-B1 specimen, SMCM spalled off during the experiment. This failure behavior showed that the adhesive performance for RC must be improved in order to utilize SMCM as repair and retrofitting material.

Management of Tuberculosis Outbreak in a Small Military Unit Following the Korean National Guideline (국내 결핵관리지침에 따른 군내 결핵 집단발병 관리 사례 보고)

  • Ji, Sang Hoon;Kim, Hee Jin;Choi, Chang Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • Background: Korean national guidelines for examining contacts with active pulmonary tuberculosis (TB) are a tuberculin skin test (TST) and chest radiographs. The treatment of a latent TB infection as performed only in those younger than six years of age who test positive for TST. Although there is a high incidence of active TB in young Korean soldiers, the current national guidelines for controlling contacts with active TB in soldiers are insufficient. This study highlights the problems with the Korean guidelines for controlling a TB outbreak in a small military unit. Material and Methods: In December of 2005, there was a tuberculosis outbreak in a military unit with a total of 464 soldiers in Kyung Gi province. The chest radiographs were taken of all the soldiers, and TST were carried out on 408 candidates. Results: In the first screening of the chest radiographs, two active TB patients were detected. By August of 2006, four additional cases were detected, making a total of six cases after the outbreak. All the patients showed active pulmonary TB or TB pleuritis. When the results of TST in the close contacts and non-close contacts were compared, there was a significant difference in the absolute size of the induration($9.70{\pm}7.50mm$ vs. $6.26{\pm}7.02mm$, p<0.001) as well as the ratio of patients showing an induration > 10mm (50.0% vs. 32.0%, p<0.001) and 15mm (33.2% vs. 20.9%, p= 0.005). Conclusion: Although the national guidelines for managing a TB outbreak in a military unit were followed, there were continuous instances of new active TB cases. This highlights the need for new guidelines to prevent the spread of TB.

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

Experimental Model of Cardiac Xenograft, Mouse Heart to Rat. (이종이형의 심장이식의 실험적 모델)

  • Kim, Byung-Il;Sohn, Sang-Tae;Shin, Sung-Ho;Chung, Won-Sang;Kim, Hyuk;Kim, Young-Hak;Kang, Jung-Ho;Jee, Heng-Ok;Lee, Chul-Burm;Seo, Jung-Kuk
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.1-4
    • /
    • 1999
  • Background: The transplantation of organs between phylogenetically disparate or harmonious species has invariably failed due to the occurrence of hyperacute rejection or accerelated acute rejection. But, concordant cardiac xenograft offer us an opportunity to study xenotransplantation in the absence of hyperacute rejection. Current therapeutics for the prolongation of survival of rodent concordant xenotransplantation are not ideal with many regimens having a high mortality rate. Cyclosporine A & Mycophenolate Mofetil are new immunosuppresive agent which has been shown to be effective at prolonging survival of allograft, as purine synthesis inhibitor. Material and Method: We used white mongrel rats as recipient and mice as donor, divided 4 groups(n=6), control group(Group 1) has no medication or pretreatment, Group 2 has splenectomy as pretreatment 7∼10 days before transplantation, Group 3 has Cyclosporine A treatment group, Group 4 has combined treatment of Cyclosporine A & Mycophenolate Mofetil(RS 61443). We compared survival time. Reuslt: We can't find significant difference of survival time between each groups. Conclusion: We concluded that rejection of cardiac xenograft was different from rejection of allograft, and new immunossuppresive Agent(Mycophenolate Mofetil, Cyclosporine A) was not effective for prolongation of survival time after cardiac xenograft.

  • PDF

COATED PARTICLE FUEL FOR HIGH TEMPERATURE GAS COOLED REACTORS

  • Verfondern, Karl;Nabielek, Heinz;Kendall, James M.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.603-616
    • /
    • 2007
  • Roy Huddle, having invented the coated particle in Harwell 1957, stated in the early 1970s that we know now everything about particles and coatings and should be going over to deal with other problems. This was on the occasion of the Dragon fuel performance information meeting London 1973: How wrong a genius be! It took until 1978 that really good particles were made in Germany, then during the Japanese HTTR production in the 1990s and finally the Chinese 2000-2001 campaign for HTR-10. Here, we present a review of history and present status. Today, good fuel is measured by different standards from the seventies: where $9*10^{-4}$ initial free heavy metal fraction was typical for early AVR carbide fuel and $3*10^{-4}$ initial free heavy metal fraction was acceptable for oxide fuel in THTR, we insist on values more than an order of magnitude below this value today. Half a percent of particle failure at the end-of-irradiation, another ancient standard, is not even acceptable today, even for the most severe accidents. While legislation and licensing has not changed, one of the reasons we insist on these improvements is the preference for passive systems rather than active controls of earlier times. After renewed HTGR interest, we are reporting about the start of new or reactivated coated particle work in several parts of the world, considering the aspects of designs/ traditional and new materials, manufacturing technologies/ quality control quality assurance, irradiation and accident performance, modeling and performance predictions, and fuel cycle aspects and spent fuel treatment. In very general terms, the coated particle should be strong, reliable, retentive, and affordable. These properties have to be quantified and will be eventually optimized for a specific application system. Results obtained so far indicate that the same particle can be used for steam cycle applications with $700-750^{\circ}C$ helium coolant gas exit, for gas turbine applications at $850-900^{\circ}C$ and for process heat/hydrogen generation applications with $950^{\circ}C$ outlet temperatures. There is a clear set of standards for modem high quality fuel in terms of low levels of heavy metal contamination, manufacture-induced particle defects during fuel body and fuel element making, irradiation/accident induced particle failures and limits on fission product release from intact particles. While gas-cooled reactor design is still open-ended with blocks for the prismatic and spherical fuel elements for the pebble-bed design, there is near worldwide agreement on high quality fuel: a $500{\mu}m$ diameter $UO_2$ kernel of 10% enrichment is surrounded by a $100{\mu}m$ thick sacrificial buffer layer to be followed by a dense inner pyrocarbon layer, a high quality silicon carbide layer of $35{\mu}m$ thickness and theoretical density and another outer pyrocarbon layer. Good performance has been demonstrated both under operational and under accident conditions, i.e. to 10% FIMA and maximum $1600^{\circ}C$ afterwards. And it is the wide-ranging demonstration experience that makes this particle superior. Recommendations are made for further work: 1. Generation of data for presently manufactured materials, e.g. SiC strength and strength distribution, PyC creep and shrinkage and many more material data sets. 2. Renewed start of irradiation and accident testing of modem coated particle fuel. 3. Analysis of existing and newly created data with a view to demonstrate satisfactory performance at burnups beyond 10% FIMA and complete fission product retention even in accidents that go beyond $1600^{\circ}C$ for a short period of time. This work should proceed at both national and international level.

Qualitative Analysis of $GeO_2$ in Germanium-Fortified Yeast. (게르마늄강화효모 내의 $GeO_2$ 정성분석)

  • Kim, So-Yeun;Kim, Myoung-Hee;Woo, Hee-Gweon;Kim, Bo-Hye;Sohn, Tsang-Uk;Jung, Jin-Wook;Baek, Dae-Heoun
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.2
    • /
    • pp.163-172
    • /
    • 2007
  • This study was designed to investigate that inorganic germanium $(GeO_2)$ did not exist in germanium-fortified yeast or obtained to non-detectable value by current analytical methods and equipments. For this purpose, we achieved $GeO_2$ qualitative analysis protocol which could be the scientific basis of the study. Since reddish brown precipitate was formed from the reaction of $GeO_2$ with 1 equiv $NaBH_4$, and dark brown precipitate was also formed from the reaction of $GeO_2$ with 2 equiv $NaBH_4$, $GeO_2$ was qualitatively analyzed by observing these particular colored-precipitates. Because no color change was showed from the reaction between $NaBH_4$ and $SiO_2$, the color change could be caused by charge transfer transition on Ge-O and B binding properties. The reaction between $NaBH_4$ and germanium-fortified yeast did not show any color change and precipitate formation which meant no $GeO_2$ existed in germanium-fortified yeast. The reaction between $NaBH_4$ and supernatant specimen collected from the outside of dialysis membrane (MWCO 1,200 dalton) did not show any color change and precipitate formation. Therefore, we considered that the both germaniums in and outside of the dialysis membrane were organic germaniums. Germanium-fortified yeast which was biosynthesized organic germanium can be applied not only as a new functional material for improving health, prevention and treatment of chronic degenerative diseases including cancers, and the regulation of immune system, but also as a new materials.

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)