• 제목/요약/키워드: neutral nonlinear system

검색결과 38건 처리시간 0.019초

3상 4선식 전력 시스템의 중성선 전류 분석 (Neutral Line Current Analysis of Three-phase Four-wire Power System)

  • 민준기;김형철;김수철;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.492-494
    • /
    • 2006
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition, and It is below CFNL=1.194 that a neutral line current could not excess the rated value

  • PDF

샘플치 퍼지 제어기 설계를 이용한 비선형 뉴트럴 시스템 제어기 설계 (Sampled-data Fuzzy Control for Nonlinear Neutral Systems)

  • 송민국;주영훈;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.195-196
    • /
    • 2008
  • This paper presents the stability analysis and design for a sampled-data fuzzy control system with neutral type of time delay. The sampling activity and neutral type of time delay will complicate the nonlinear system dynamics. And it make the stability analysis much more difficult than that for a continuous-time fuzzy control system. Based on the fuzzy control approach, linear matrix inequality (LMI)-based stability conditions are derived to guarantee the neutral T-S fuzzy system stability. Finally, an example is provided to illustrate the effectiveness of the proposed approach.

  • PDF

Existence Results for the Nonlinear First Order Fuzzy Neutral Integrodifferential Equations

  • Radhakrishnan, Bheeman;Nagarajan, Murugesan;Narayanamoorthy, Samayan
    • Kyungpook Mathematical Journal
    • /
    • 제53권1호
    • /
    • pp.87-98
    • /
    • 2013
  • In this paper, we devoted to study the existence and uniqueness of nonlinear fuzzy neutral integrodifferential equations. Moreover we study the fuzzy solution for the normal, convex, upper semicontinuous, and compactly supported interval fuzzy number. The results are obtained by using the Banach fixed-point theorem. An example is provided to illustrate the theory.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

뉴트럴 타입 시간 지연을 갖는 네트워크 기반 시스템의 샘플치 퍼지 제어기 설계 (Sampled-data Fuzzy Controller for Network-based Systems with Neutral Type Delays)

  • 주영훈
    • 한국지능시스템학회논문지
    • /
    • 제18권2호
    • /
    • pp.151-156
    • /
    • 2008
  • 본 논문은 뉴트럴 타입 시간 지연을 가지는 네트워크 기반 시스템의 안정도 분석 및 샘플치 퍼지 제어기 설계 방법에 관하여 논의한다. 먼저 대상이 되는 비선형 네트워크 시스템을 T-S (Takagi-Sugeno) 퍼지 모델로 표현한다. 제안하는 샘플치 퍼지 제어기를 모델링하는 퍼지 규칙과 같은 멤버쉽 함수를 가지게 설계한다. Lyapunov-Krasovskii의 안정화 이론을 도입하여 이를 바탕으로 뉴트럴 형태의 시간 지연을 갖는 T-S 퍼지 시스템의 안정도를 판별한다. T-S 퍼지 시스템의 안정도 조건을 제시하고 선형 행렬 부등식의 형태로 표현한다. 제안된 선형 행렬 부등식의 해를 통하여 샘플치 퍼지 제어기의 이득 값을 설계한다. 마지막으로, 본 논문에서 제안한 방법의 적용 가능성과 일반성을 평가하기 위하여 수치적인 예를 적용한다.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

EXISTENCE AND STABILITY RESULTS FOR STOCHASTIC FRACTIONAL NEUTRAL DIFFERENTIAL EQUATIONS WITH GAUSSIAN NOISE AND LÉVY NOISE

  • P. Umamaheswari;K. Balachandran;N. Annapoorani;Daewook Kim
    • Nonlinear Functional Analysis and Applications
    • /
    • 제28권2호
    • /
    • pp.365-382
    • /
    • 2023
  • In this paper we prove the existence and uniqueness of solution of stochastic fractional neutral differential equations with Gaussian noise or Lévy noise by using the Picard-Lindelöf successive approximation scheme. Further stability results of nonlinear stochastic fractional dynamical system with Gaussian and Lévy noises are established. Examples are provided to illustrate the theoretical results.

단상 인버터를 사용한 중성선 전류 저감 기법 (Neutral Current Reduction Method Using Single-Phase Inverter)

  • 민준기;김효성;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.155-157
    • /
    • 2005
  • This paper analyzed the adoption possibility of a low cost single phase active power filter as the neutral current reduction device in three-phase four-wire power system with the balanced or/and unbalnaced nonlinear load conditions. Proposed system can make neutral line current to within rated vale without the phase current THD change of the installed phase line.

  • PDF

EXISTENCE AND REGULARITY FOR SEMILINEAR NEUTRAL DIFFERENTIAL EQUATIONS IN HILBERT SPACES

  • Jeong, Jin-Mun
    • East Asian mathematical journal
    • /
    • 제30권5호
    • /
    • pp.631-637
    • /
    • 2014
  • In this paper, we construct some results on the existence and regularity for solutions of neutral functional differential equations with unbounded principal operators in Hilbert spaces. In order to establish the existence and regularity for solutions of the neutral system by using fractional power of operators and the local Lipschtiz continuity of nonlinear term without using many of the strong restrictions considering in the previous literature.