• Title/Summary/Keyword: near power

Search Result 1,793, Processing Time 0.038 seconds

Comparative Analysis of Structural Damage Potentials Observed in the 9.12 Gyeongju and 11.15 Pohang Earthquakes (9.12 경주지진 및 11.15 포항지진의 구조손상 포텐셜 비교연구)

  • Lee, Cheol-Ho;Kim, Sung-Yong;Park, Ji-Hun;Kim, Dong-Kwan;Kim, Tae-Jin;Park, Kyoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.175-184
    • /
    • 2018
  • In this paper, comparative analysis of the 9.12 Gyeongju and 11.15 Pohang earthquakes was conducted in order to provide probable explanations and reasons for the damage observed in the 11.15 Pohang earthquake from both earthquake and structural engineering perspectives. The damage potentials like Arias intensity, effective peak ground acceleration, etc observed in the 11.15 Pohang earthquake were generally weaker than those of the 9.12 Gyeongju earthquake. However, in contrast to the high-frequency dominant nature of the 9.12 Gyeongju earthquake records, the spectral power of PHA2 record observed in the soft soil site was highly concentrated around 2Hz. The base shear around 2 Hz frequency was as high as 40% building weight. This frequency band is very close to the fundamental frequency of the piloti-type buildings severely damaged in the northern part of Pohang. Unfortunately, in addition to inherent vertical irregularity, most of the damaged piloti-type buildings had plan irregularity as well and were non-seismic. All these contributed to the fatal damage. Inelastic dynamic analysis indicated that PHA2 record demands system ductility capacity of 3.5 for a structure with a fundamental period of 0.5 sec and yield base shear strength of 10% building weight. The system ductility level of 3.5 seems very difficult to be achievable in non-seismic brittle piloti-type buildings. The soil profile of the PHA2 site was inversely estimated based on deconvolution technique and trial-error procedure with utilizing available records measured at several rock sites during the 11.15 Pohang earthquake. The soil profile estimated was very typical of soil class D, implying significant soil amplification in the 11.15 Pohang earthquake. The 11.15 Pohang earthquake gave us the expensive lesson that near-collapse damage to irregular and brittle buildings is highly possible when soil is soft and epicenter is close, although the earthquake magnitude is just minor to moderate (M 5+).

Energy Reduction Methods using Energy-aware QoS Routing Scheme and Its Characteristics in IP Networks (IP Network에서 Energy-aware QoS Routing에 의한 에너지 감소 방법 및 특성)

  • Han, Chimoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.27-34
    • /
    • 2012
  • Today the energy consumption of ICT networks is about 10% of the worldwide power consumption and will be remarkably increased in the near future. For that reason, the energy saving topics of ICT networks are actually studying in various research institutes. This paper studies the possible energy saving methods assuring the QoS of networks on network level. This paper assumed the energy consumption models according to energy profiles of node and link in IP networks. Especially it formulates the energy problem of a minimum energy consumption with various energy profile models and suggests the methods of energy-aware QoS routing under energy saving and network QoS sustaining condition. It shows the large difference of energy saving according to energy profiles and the possibility of energy saving by using the appropriate energy profile model in the simulation experiment. This paper shows that min_used_path(MP) heuristic of energy-aware QoS routing is the excellent method compared with other heuristic methods as view of reduction ratio of nodes and links and energy saving effect under network QoS sustaining condition. As a result, this paper confirms that the min_used_path(MP) heuristic of energy-aware QoS routing can get energy saving and sustaining of network QoS in IP networks.

Quality Control of Observed Temperature Time Series from the Korea Ocean Research Stations: Preliminary Application of Ocean Observation Initiative's Approach and Its Limitation (해양과학기지 시계열 관측 자료 품질관리 시스템 구축: 국제 관측자료 품질관리 방안 수온 관측 자료 시범적용과 문제점)

  • Min, Yongchim;Jeong, Jin-Yong;Jang, Chan Joo;Lee, Jaeik;Jeong, Jongmin;Min, In-Ki;Shim, Jae-Seol;Kim, Yong Sun
    • Ocean and Polar Research
    • /
    • v.42 no.3
    • /
    • pp.195-210
    • /
    • 2020
  • The observed time series from the Korea Ocean Research Stations (KORS) in the Yellow and East China Seas (YECS) have various sources of noise, including bio-fouling on the underwater sensors, intermittent depletion of power, cable leakage, and interference between the sensors' signals. Besides these technical issues, intricate waves associated with background tidal currents tend to result in substantial oscillations in oceanic time series. Such technical and environmental issues require a regionally optimized automatic quality control (QC) procedure. Before the achievement of this ultimate goal, we examined the approach of the Ocean Observatories Initiative (OOI)'s standard QC to investigate whether this procedure is pertinent to the KORS. The OOI QC consists of three categorized tests of global/local range of data, temporal variation including spike and gradient, and sensor-related issues associated with its stuck and drift. These OOI QC algorithms have been applied to the water temperature time series from the Ieodo station, one of the KORS. Obvious outliers are flagged successfully by the global/local range checks and the spike check. Both stuck and drift checks barely detected sensor-related errors, owing to frequent sensor cleaning and maintenance. The gradient check, however, fails to flag the remained outliers that tend to stick together closely, as well as often tend to mark probably good data as wrong data, especially data characterized by considerable fluctuations near the thermocline. These results suggest that the gradient check might not be relevant to observations involving considerable natural fluctuations as well as technical issues. Our study highlights the necessity of a new algorithm such as a standard deviation-based outlier check using multiple moving windows to replace the gradient check and an additional algorithm of an inter-consistency check with a related variable to build a standard QC procedure for the KORS.

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

A Study on PWM Speed Controller for Long line Fishing Motor (어로 작업용 연승기 전동기의 PWM 속도제어기에 관한 연구)

  • Vuong, Duc-Phuc;Bae, Cherl-O;Ahn, Byong-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.97-102
    • /
    • 2015
  • The long line fishing machine is combined with motor and two disc rollers has used on the small size fishing-boat under 1 ton located in near Jeollanam-do seaside. The long line fishing motor is controlled only one direction because the fishing line is loaded heavily at pulling up. On this paper we made the long line fishing 400W power motor controller which it was usually applied under 1 ton fishing boat, and designed the controller using PWM chip, Half bridge driver and MOSFET for one direction motor control. Furthermore some user convenience devices were added like battery indicator and safety protection circuit for battery overdischarge and battery source wire mismatch connection. So we protected the battery from overdicharging when the battery voltage was below 11.5V and fishermen didn't need to worry about source lines misconnection anymore. We confirmed the test version of controller was the good working condition at land and sea.

Quantum Dot-Sensitized Solar Cells Based on Mesoporous TiO2 Thin Films (메조포러스 이산화티타늄 박막 기반 양자점-감응 태양전지)

  • Lee, Hyo Joong
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This review article summarizes the recent progress of quantum dot (QD)-sensitized solar cells based on mesoporous $TiO_2$ thin films. From the intrinsic characteristics of nanoscale inorganic QDs with various compositions, it was possible to construct a variety of 3rd-generation thin film solar cells by solution process. Depending on preparation methods, colloidal QD sensitizers are pre-prepared for later deposition onto the surface of $TiO_2$ or in-situ deposition of QDs from chemical bath is done for direct growth of QD sensitizers over substrates. Recently, colloidal QD sensitizers have shown an overall power conversion efficiency of ~7% by a very precise control of composition while a representative CdS/CdSe from chemical bath deposition have done ~5% with polysulfide electrolytes. In the near future, it is necessary to carry out systematic investigations for developing new hole-conducting materials and controlling interfaces within the cell, thus leading to an enhancement of both open-circuit voltage and fill factor while keeping the current high value of photocurrents from QDs towards more efficient and stable QD-sensitized solar cells.

Experimental Study of Performance of PEMFC Operated in Dead-End Mode (수소극 Dead-End 모드 고분자 전해질 연료전지의 실험적 연구)

  • Ji, Sang-Hoon;Hwang, Yong-Sheen;Choi, Jong-Won;Lee, Dae-Young;Park, Joon-Ho;Jang, Jae-Hyuk;Kim, Min-Soo;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.643-648
    • /
    • 2010
  • Portable fuel cells are commonly operated in the dead-end mode because of such as high fuel utilization. However, the performance of such systems deteriorates continuously with an increase in the amount of by-products such as water vapor and nitrogen. In this study, to verify the effect of water vapor on Proton Exchange Membrane Fuel Cells (PEMFCs), constant-load experiments were carried out for a current density of 600 mA/cm2 and a voltage of 0.4 V, respectively. The performance of the cell was more stable under constant voltage conditions than under constant current density conditions. Condensed water accumulated in the anode channel near the cell outlet. The experimental results show how the relative humidity (RH = 0.15, 0.4 and 0.75) of air at the cathode side affect the performance of PEMFCs with dead-end anode. At RH values higher than 0.15, the mean power density increased by up to 51% and the mean purge duration decreased by up to 25% compared to the corresponding initial values.

The Directivity of Traditional Architectural Space in Korean and Japanese (한국${\cdot}$일본 전통건축공간의 지향성)

  • Kim Dong-Young
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.101-109
    • /
    • 2005
  • As a circumstantial-existance character (the human character who takes action after grasping circumstances and fears things with reason) the Japanese were more interested in the active doctrines of Wang Yang-ming than other speculative studies. All of people were inhumanely incorporated into the rigorous class system under pressure in the samurai society. In the atmosphere of the society a natural phenomenon was understood as the ksana of change, and instead of the whole, the part was mainly described with emphasis on the reality. Therefore nature came near to the man after being reduced and then was symbolized in the Interior space. Also the classification of spaces, that is to say, the settlement of borders by the social position was shown in the great interior space like a labyrinth. As a self-existance character(the human style who carves out for and does not have a regard other's feeling), however, the Korean were much influenced by the Taoist Idea as they tried to be similar to nature in nature itself. Therefore the idea of Asaniskrota was in their origin. There was a tendency for space to be extended toward the outdoor in Korea, since the Korean people who are speculative and like to be natural tried to be close to nature. Therefore the division of spaces according to class and sexuality and the settlement of borders were already shown in outside by Che-Na-Num(Divided-Mass:Koren's own style). These are closely related with that houses were built after a village settle down in Korea while built before a village settle down in Japan. Architectural space consists of the interior and the exterior. The layout and (on of architectural space has a great variety of characters by region and culture. In other words, it can be understood which has a priority between the interior and the exterior in developing the layout and the form of architectural space. Belonging to the culture area of Chinese characters with Korea, Japan has maintained its own Identity. It has an identity in the layout and form of architectural space as well. Therefore, the architecture and architectural theories of the two countries were compared and analyzed with priority given to the traditional architecture, also the backgrounds of architecture and architectural theories of two countries were examined in this study. This study shows that each country has different characters in how to introduce nature, how to expand space and how to compose windows, including the view of nature and the cult of space. As a result, the space in Korean architecture has relatively the exterior-oriented character but in Japan architecture spatial character is interior-oriented. The interior-oriented character can be relevant to the word 'reduction' and the exterior-oriented character to 'extension' after all. Also it can be thought that each character has a great relation with climate and idea of people in power.

Developement of Planar Active Array Antenna System for Radar (평면형 능동 위상 배열 레이더용 안테나 시스템 개발)

  • Chon, Sang-Mi;Na, Hyung-Gi;Kim, Soo-Bum;Lee, Jeong-Won;Kim, Dong-Yoon;Kim, Seon-Joo;Ahn, Chang-Soo;Lee, Chang-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1340-1350
    • /
    • 2009
  • The design and implementation of planar Active Phased Array Antenna System are described in this paper. This Antenna system operates at X-band with its bandwidth 10 % and dual polarization is realized using dual slot feeding microstrip patch antenna and SPDT(Single Pole Double Through) switch. Array Structure is $16\times16$ triangular lattice structure and each array is composed of TR(Transmit & Receive) module with more than 40 dBm power. Each TR module includes digital attenuator and phase shifter so that antenna beam can be electronically steered over a scan angle$({\pm}60^{\circ})$. Measurement of antenna pattern is conducted using a near field chamber and the results coincide with the expected beam pattern. From these results, it can be convinced that this antenna can be used with control of beam steering and beam shaping.

The Integrated Measurement and Analysis System for T-DMB (T-DMB를 위한 통합 측정 및 분석 시스템)

  • Kim, Sang-Hun;Kim, Young-Min;Kim, Man-Sik;Kim, Gyu-Young
    • Journal of Broadcast Engineering
    • /
    • v.12 no.1 s.34
    • /
    • pp.11-27
    • /
    • 2007
  • T-DMB(Terrestrial-Digital Multimedia Broadcasting) for portable and mobile broadcasting service was officially launched in the metropolitan area of Korea in December 2005. The development of interactive data services and the expansion of T-DMB network have been now progressed, and the regional T-DMB broadcasters will be selected in the near future. Although it is important to evaluate service area and reduce a fringe area for optimizing RF coverage of T-DMB, there was no professional system to support those works, and therefore lots of resources in budget, manpower and time were required. The measurement considering characteristics of SFN(Single Frequency Network) is essential in the implementation of T-DMB network which needs to control synchronization, spacing and output power of transmitters. In addition, mobile measurement, enough measured parameters for many-sided analysis of reception quality, efficient management of enormous measured data and representation of measured results on the electronic map are also important in evaluating service area. In this paper, we derived requirements for a new measurement system in T-DMB by considering the above details, and we proposed and developed an integrated measurement and analysis system. The developed system was applied to the implementation of T-DMB network of KBS and field tests, and it proved its efficiency and accuracy in result.