• Title/Summary/Keyword: natural ventilation

Search Result 430, Processing Time 0.029 seconds

A Study on the Environment-friendly Planning Elements on High-Class Houses Kuangajeong in Chosun Dynasty (관가정(觀稼亭)으로 본 조선시대 상류주택의 환경친화적 계획요소 분석)

  • Heo, Jun;Lee, Shi Young;Song, Byeong Hwa
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.164-177
    • /
    • 2011
  • This study aims to examine the traditional living space to reflect the environment-friendly design methods and principles of reestablishment. To do so, this study carried on a related literature study and field survey. The traditional living space in terms of the environmental friendliness is reflected on site selection and space composition, and utilization of natural energy and natural materials. Focused on the Kwangajeong in Yangdong Village, this study is to identify eco-friendly techniques on the traditional living space. As a result, it shows that Kwangajeong with the side of the southeast in site selection had been considered in aspect of environmental control such as sunshine and solar radiation. Also building construction techniques had been used to minimize the variation of terrain. In aspect of environmental conservation, Kwangajeong had structurally arranged the gate, an inner yard and an inner floor to allow good ventilation. In aspect of space composition, Kwangajeong with the emphasis of scenic view had utilized the methods that attract external landscape through the control of its fences. Environment-friendly techniques and control principles in traditional space had been developed by a long experience through the long periods and the traditional techniques suitable for local climate and local environment have been developed. The technical development of these techniques to resolve the global environmental and energy issues and create a more pleasant living environment of human beings might be critical.

Trace element Analysis and Source Assessment of Apartment Parking Lot Dust in Daegu, Korea (공동주택 주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Bae, Gun-Ho;Jung, Cheol-Su;Park, Kyu-Tae;Lee, Myoung-Sook;Shin, Dong-Chan;Kim, Yong-Hye;Yoon, Min-Hye;Han, Young-Jin;Choi, Hyuek;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.756-766
    • /
    • 2011
  • In order to investigate the degree of apartment parking lot dust contamination, total 72 samples of parking lot dust (36 from ground parking lots and 36 from the underground parking lots) were collected in Daegu city from the end of March to the early June 2010. The dust samples were sieved below $100{\mu}m$, and analysed by ICP for 14 elements after an acid extraction. Results obtained from the source assessment of trace element using enrichment factor showed that Fe, K, Mg, Mn, Na and V were influenced by natural sources, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources in both the ground parking lot and the underground parking lot. And results showed that Ca were influenced by natural sources in the ground parking lot, but influenced by anthropogenic sources in the underground parking lot. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Underground parking lot dust was more affected by anthropogenic sources and contaminated compared with the ground parking lot dust. Pollution index of heavy metals revealed that underground parking lot dust was 5.5 times more contaminated with heavy metal components than the ground parking lot dust. The results of correlation analysis among trace elements indicated that components in the ground parking lot were more correlated than those in the underground parking lot, and especially more correlated with natural sources-natural sources. Analysis for correlations between components and influencing factors in the underground parking lot showed that concentrations of heavy metals were higher with smaller number of parking spaces and no ventilation system, and older apartments in last paint and cleaning had relatively higher contents of heavy metals than those of recently painted and cleaned.

Response of the Growth and Root Development of Shade Landscape Plants by Slit Ventilation Treatment into Indoor Container (실내용기 내 슬릿(Slit)처리가 내음성 조경식물의 생육과 뿌리발달에 미치는 영향)

  • Ju, Jin-Hee;Han, Jung-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.105-112
    • /
    • 2009
  • This study has attempted to facilitate various new technologies related to indoor containers and develop a desirable planting environment after investigating the growth (including root growth) of shade-tolerant landscape plants under slit processing, a natural indoor ventilation system. The following results were found: In terms of the shoot growth of Fatsia japonica in a slit container, no distinctive difference was observed in comparison with the control group. However, growth was good when the container 250mm tall or taller. Therefore, it was verified that optical soil depth is more important than slit processing in shoot growth of Fatsia japonica. In Fatsia japonica root length was observed as follows: Control 2(250mm) > Slit 2(250mm) > Control 1(195mm) > Slit 3(360mm) > Control 3(360mm) > Slit 1(195mm). The largest growth was observed in Control 2(250mm), which had no slit processing. In term of root width, this was lower than the initial value in all groups, which means that the root grew vertically, not horizontally. In terms of plant height of Ophiopogon japonicus, a gradual increase was observed in the control group that had no slit processing. No significant growth was detected in the slit system, however. In terms of shoot number, slit containers were generally higher than the control group. In terms of fresh and dry weights, on the contrary, slit containers were mostly lower than the control group. In Ophiopogon japonicus, root length was observed as follows: Slit 2(250mm) > Slit 1(195mm) > Control 2(250mm) > Control 3(360mm) > Slit 3(360mm) > Control 1(195mm). In Ardisia japonica, slit containers were mostly greater than control group in terms of plant height. The greatest plant height was observed at Slit 2(250mm) instead of Slit 1(195mm) and Slit 3(360mm). Except for plant height and shoot number, however, no significant shoot and root growth was observed. Root length was observed as follows: Slit 2(250mm) > Slit 3(360mm) > Control 3(360mm) > Slit 1(195mm) > Control 2(250mm) > Control 1(195mm). Therefore, root length in slit containers was mostly greater than in the control group. The width of root, however, declined in general.

Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments (도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구)

  • Suh, Byung-Seong;Kim, Sung-Hwan;Kim, In-Shik;Hur, Yun-Young;Do, Sou-Young;Kim, Jung-Man;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.609-622
    • /
    • 1997
  • Nitrogen dioxide $(NO_2)$ has been regarded as one of the main elements among air pollutants, and we measured $NO_2$ levels of near gas range, kitchen, living room and outdoor on 489 apartments in Pusan area. $NO_2$ were sampled by using Palmes tubes (diffusion tube sampler) during August 16-25, 1995 (summer) and January 15-29, 1996 (winter), respectively. Authors wanted to know comparison of $NO_2$ levels in summer and winter, $NO_2$ levels categorized by variables, and variables affected to $NO_2$ levels. According to this study, we conducted to establish the degree of indoor-outdoor air pollution of urban apartments in Korea and methods to reduce indoor air pollution. The results of this study were summarized as follows: 1) Mean $NO_2$ levels of near gas range, kitchen, living room, and outdoor were $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb,\;and\;19.0{\pm}6.0ppb$ in summer, and $34.5{\pm}16.8ppb,\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb,\;21.8{\pm}9.8ppb$ in winter, respectively. 2) Mean $NO_2$ levels according to the floor levels were not significantly different in summer, and in winter, $NO_2$ levels were decreased as the floor levels were increasing, but those were increased above 16th floor. 3) Variables showing significant correlation(p<0.05) with $NO_2$ levels were as follows; Summer: floor level, family size, number of family during a meal, number using gas range during rice cooking per day, and natural ventilation. Winter: floor level, family size, number of person who have been respiratory disease in a house, number of family during a meal, total number of meals, and number using gas range during rice or side-dish cooking per day. 4) We suggest that the methods of reducing indoor $NO_2$ levels are ventilation during cooking, complete combustion, decreasing number and time of cooking, and substitution of fuels.

  • PDF

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.117-124
    • /
    • 2020
  • In this paper, we proposed a plan to maintain comfortable indoor air quality in nursing homes by suggesting ways to reduce items temporarily exceeding the reference values through real-time concentration variation analysis of indoor air quality. Five items including PM10, CO2, CO, VOC, and Radon are measured at nursing homes in spring (April) and autumn (September) was carried out and all of the measured items were analyzed to satisfy the criteria set by the Indoor Air Quality Control Act. As a result of the analysis of the real-time concentration change, the concentration of CO2 was close to the reference value based on the number of occupants in the sick room. Due to the disinfectant (alcohol) used to disinfect and the auxiliary tools (adhesive) used in the operation of the program such as making and coloring, it was analyzed to temporarily exceed the standard value in the hall. In conclusion, it is possible to provide pleasant indoor air quality and contribute to securing the nursing home's competitiveness if periodic ventilation, natural disinfectant and eco-friendly product are used in consideration of the thermal environment.

Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System (일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.176-181
    • /
    • 2011
  • The fan and pad evaporative cooling system is one of the main cooling methods in greenhouses. Its efficiency is very high, but it has some disadvantages as temperature gradient in greenhouse is large. This study was conducted to reduce the internal temperature gradients in the fan and pad cooling greenhouses. Experiments on cooling performance were carried out in a greenhouse equipped with air duct and integrated fan and pad system as an idea of this study. It showed that the cooling efficiency of an integrated fan and pad system was 75.7% in the first stage and 88.6% in the second stage. When this cooling system was operated for an unshaded and a shaded greenhouse, there were cooling effects of $5.7\sim7.6^{\circ}C$ and $7.4\sim9.7^{\circ}C$ to the control greenhouse, respectively. Maximum temperature differences in a cooling greenhouse, with a length of 18m, were $1.6\sim1.7^{\circ}C$ for shaded conditions and $2.3\sim2.7^{\circ}C$ for unshaded conditions. This greenhouse cooling method, with air duct and integrated fan and pad system, can reduce about 40~50% of the internal temperature gradients in the usual fan and pad cooling greenhouses.

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.