• 제목/요약/키워드: natural light environment

검색결과 342건 처리시간 0.029초

아파트 동남향·서남향 배치에 따른 물리적 주거환경에 대한 비교연구 - 강남 H아파트 사례를 중심으로 - (A Comparative study on Physical residential environments of Apartment facing Southeast and Southwest aspect Arrangement - Focus on the Case Study of Gangnam H Apartment -)

  • 조장현;현은미;김용식
    • 한국실내디자인학회논문집
    • /
    • 제21권5호
    • /
    • pp.272-279
    • /
    • 2012
  • Apartments with a southern exposure are often thought to have advantages in receiving winter sunlights and summer natural ventilation. However, as due-south-apartments increase recently, the consideration for residential environment for households with no southern exposure is necessary. In case of due-south-apartments, residents prefer east-sided apartments than west facing apartments which might receive more hot sunlight in the afternoon; however in case of west-oriented apartments with active ventilation, the interior area is bright until late afternoon without unpleasant heat and has advantage in light environment aspects. This study aims to compare and analyze merits and demerits of air flow and sunlighted environment of buildings through sunshine duration simulation using CFD simulation ad sunlights about southeast-sided and southwest-sided apartments based on general opinions for apartment directions. As results of the interior natural ventilation analysis, as the average air flow speed in southwest-sided apartments was 1m/s faster than that of southeast-sided, it has effects of lowering sensory temperature of residents in summer, and for sunlighted environment, southwest-sided apartments are advantageous for sunlighted area for duration time inside. As a result of the research, the calculation of physical residential environment of apartment residential space should be reached through integrated evaluation of natural ventilation and sunlighted time from placement and facing direction of the buildings considering characteristics and environment of each apartment, not based on general opinions.

  • PDF

병실의 자연광 환경에 따른 환자들의 입원기간 비교 (The Comparison of hospitalization time of Patients According to Natural Light in Hospital)

  • 김형섭;김민성;이주윤;송규동
    • KIEAE Journal
    • /
    • 제5권2호
    • /
    • pp.35-41
    • /
    • 2005
  • This study was conducted to identify the effect of daylighting in hospitals on hospitalization time of patients and patients' outcomes in hospitals. Two major variations include orientation of hospital wards and the hospitalization times of various kinds of patients. Patients' data were obtained from two hospitals located in Seoul, Korea. The hospital buildings have north-facing and north-facing wards. The patients were classified according to the types of diseases and the orientation of the patient rooms. Then, statistical T-tests were applied in order to verify if natural light might shorter the hospitalization time of patients. The study also identified the types of diseases that were more responsive to the quantity of natural light in patient rooms. This information may be used as a basis for the development of guidelines for patient rooms in hospitals to achieve more effective healing environments. Likewise, the results may be applied to medical treatment buildings, recreational centers and hospital as well.

저광도 조건시 참외의 적과와 엽면시비 효과 (Effect of Fruit Thinning and Foliar Fertilization under the Low Light Intensity in Oriental Melon(Cucumis melo L. var. makuwa MAKINO))

  • 서태철;강용구;윤형권;김영철;서효덕;이상규
    • 생물환경조절학회지
    • /
    • 제12권1호
    • /
    • pp.17-21
    • /
    • 2003
  • 참외재배시 저광도 조건시 상품수량의 급격한 저하를 막기 위하여 본 연구가 수행되었다. 과실 비대기에 해당되는 착과후 10일부터 400 $\mu$mol$.$m$^{-}$2$.$S$^{-1}$정도의 저광도 조건이 지속되면 광합성 속도도 떨어지고, 엽록소 함량도 낮았으며 특히 요소 무엽면시비구의 광합성속도는 크게 저하되었다 당도에 있어서는 자연광에 비해 저광도 처리구가 전반적으로 낮았는데, 착과수가 많고 무엽면시비구일수록 낮았다. 발효과 발생률은 요소 엽면시비 유무에 관계없이 자연광에서는 4% 미만으로 발생되었는데, 저광도 조건에서는 10% 이상 발생되었다. 특히 저광도 조건에서 적과수를 적게 한 처리구일수록 발효과 발생률이 높았는데, 적과를 하지 않은 처리구는 각각 39와 48%로 매우 높은 발생율을 보였다. 수확시기 지연은 요소 엽면시비 유무와 관계없이 자연광에 비해 저광도 조건에서 늦어지는 경향을 보였는데, 적과수가 적을수록 지연정도는 심했다 주당 상품수량에 있어서는 저광도 조건하에서 자연광에 비해 16∼34% 수준 정도로 매우 낮은 수량을 보였는데, 요소 0.5% 액을 엽면시비하고 2개를 적과한 처리구가 34%수준으로 자연광에 비해 다른 처리보다 높은 상품수량을 보였다. 따라서 참외재배시 과실 착과후 10일경부터 강우 등에 의해 장기간 저광도 조건이 지속될 것으로 전망되면 상품수량의 급격한 저하를 막기 위하여 주당 6개의 착과 과실중에서 2개를 적과하고, 요소 0.5%액을 2회 정도 엽면시비 해주는 것이 바람직 할 것으로 사료된다.

오피스 휴게공간에서 자연요소의 심리적 효과에 관한 연구 (A Study on Psychological Effect of Natural Element in Rest Space of Office)

  • 강민경;류호창
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.84-87
    • /
    • 2004
  • The stress from the office environment comes from the most psychological things. Therefore, the purpose of this study is to research the psychological effect of natural element for office worker's psychological stability. This study is focused on the light, sound, air, temperature, plant, and water. Perception of these natural elements through the senses of sight, auditory, smell, and touch is effect on human body and mind directly. The application of natural elements provide a health of office workers. The result will show that, with application of the natural element, the rest space will be more powerful for health of workers. And also combination of natural element and geometric pattern will be very useful to prepare healing environment on the rest space

  • PDF

리차드 마이어의 주거 건축에 나타난 공간 설계 변화 연구 (A Study on the Variation of Residential Architectural Space Designed by Richard Meier)

  • 이선민;조은란;허범팔
    • 한국실내디자인학회논문집
    • /
    • 제20권2호
    • /
    • pp.131-138
    • /
    • 2011
  • This study describes development process of residential architectural space in the Richard Meier's residential works through chronological analysis. By analyzing house layout, floor plan, elevation, materials and colors and light entering of his residential works, changes in his architectural space has been studied. Richard Meier's early work is designed as three-dimensional shape, and places emphasis on geometric form. However, recently completed residential works by Richard Meier focuses on the horizontal sun shading louvers, which has ability. In addition, teak and a special UV protective glass are used to control natural environment. Through this research, it was found that Richard Meier has maintained his architectural language in terms of the design layout of the house and planar with colors that appear on the initial project. Using light input methods and materials used for active development, it was found that many design elements were applied and developed.

공동주택 지하주차장의 자연채광 실태 및 채광성능 평가 (Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation)

  • 정유근;김정태
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

광파이프 시스템의 조명기술 및 건축적 활용 연구 (A study on light pipe system technology and its application)

  • 신주영;김곤;김정태
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.69-76
    • /
    • 2009
  • The use of natural light can improve the quality of indoor environment and also occupants health. In recent years, with an increasing awareness of sustainable development, various innovative methods of integrating daylight into the building have been developed. One such device is the light pipe system. The light pipes are innovative daylighting system that allow the transmission of daylight into the hard-to-reach indoor space. The system consist of mainly three parts. First, a top collector which is mounted on the outside of the roof and gathers skylight and sunlight. Second, light-reflective tube which is coated with highly reflective mirror finish material to transmit the daylight into the diffuser. Third, a diffuser which is installed on the ceiling in the room and spread the daylight into the room. Light pipes have been widely used and researched in many countries such as Australia, America, Canada and Britain. However, despite the significant daylight potential, little work have been carried out in Korea compare to the other countries. In this study, recent lighting technology and application of light pipe system in both Korea and other countries have been compared. For the results, the benefits of each light pipe system and suitable application in Korea is also discussed.

학교건축의 친환경적 계획수법에 대한 사례연구 - 미국, 일본, 한국의 학교건축을 중심으로 - (A Study on Examples of Eco-Friendly School Design - Focusing on School Facilities in USA, Japan and Korea -)

  • 이지영;이경선
    • 교육시설 논문지
    • /
    • 제18권2호
    • /
    • pp.3-14
    • /
    • 2011
  • This study aims to identify differences and lessons in eco-school planning techniques and sustainable design methods by analyzing comparatively green building certification system and the cases of sustainable schools in US, Korea and Japan. As a result of the comparative analysis, green building certification system for school facilities, both domestic and international, is categorized into external environment, energy, materials and resources, and indoor environment. From the case study, it is common that roof garden and biotopes are installed for external environment, while energy saving, passive energy utilization methods for natural lighting and ventilation such as arrangement planning, courtyard, top-light, shading devices, solar panel and insulation by roof garden are most frequently used. Also, storm water uses, water saving equipment and sustainable materials are often introduced for resource savings. Concerns for indoor environment is frequently addressed by introducing natural light and ventilation in the buildings, which makes ultimately a comfortable space.

  • PDF

실거주환경 기반 빛환경 에너지 성능평가 방법 제안 연구 (A Study to Suggest a Method to Evaluate Light Environment Energy Performance based on Actual Residence Environments)

  • 김상훈;이행우;김용성
    • 한국디지털건축인테리어학회논문집
    • /
    • 제13권4호
    • /
    • pp.33-39
    • /
    • 2013
  • As lighting energy consumption in buildings occupies high ratio, technical researches to solve it have been constantly carried out. However, basic studies on light environment performance evaluation is actually deficient and only at a level of a simple illumination monitoring. Thus, this study has suggest a light environment energy performance evaluation based on actual residence environments to allow setting lighting interoperation and user required illumination. Conclusions from the study are as follows: 1) As the performance evaluation suggested by this study has not only derived lighting energy usage as well as monitored simple indoor illumination distribution, it is quantitative and allows derivation of visual results. 2) The performance evaluation suggested by this study allows inputs of user required illumination through the performance evaluation server, which is able to support for performance evaluations for various works and users. 3) This study has verified validity of the performance evaluation method by analyzing results of lighting energy reduction by executing performance evaluation on changes of light shelf that is a natural lighting system through the suggested performance evaluation method. This study is significant from a viewpoint that it has suggested a quantitative performance evaluation method on the basis of actual residence environments. Those researches concerned on the energy performance evaluation should be constantly progressed from an aspect that they are another solution of the energy problems.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.