• Title/Summary/Keyword: natural convection

Search Result 848, Processing Time 0.03 seconds

A Numerical Study for Natural Convective Heat Transfer by Finite Element Method (유한요소법을 이용한 자연대류열전달 수치해석 연구)

  • ;Ashley F. Emery
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • In natural convection flows, the fluid velocities are highly dependent on the thermal field and property variations can have a strong effect on both the flow and thermal fields. To examine the effect of property variations, at first, numerical analyses covering wide range of the Prandtl number under the same Rayleigh numbers have been carried out. Next, we have modeled the viscosity and thermal conductivity as parabolic functions of temperature and a comprehensive set of numerical solutions have been obtained to understand the effect. The Prandtl number dependence of Nusselt number is fairly strong even though the effect is still weak compared to the Rayleigh number dependence. When thermophysical properties are dependent on temperature, the flow field showed a fairly weak variation except near boundaries, whereas the temperature field is strongly affected, especially by the temperature dependent thermal conductivity.

  • PDF

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF

A Study on the Local Boiling of the Consolidated Spent Fuel Storage Pool (조밀화된 사용후 핵연료 저장조에서의 국부 비등에 관한 연구)

  • Lee, Chang-Ju;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.8-19
    • /
    • 1993
  • The natural convection model of the consolidated system has been developed to make sure the removal of decay heat generated in the spent fuel for the loss of forced cooling accident. The numerical technique employed was based on the ADI scheme. The calculation of heat generation rate in the spent fuel was peformed by the ANS-79 decay heat model, and the nonuniform surface heat flux is assumed with a chopped sine curve for the conservative decay heat generation input. The sensitivity study was performed to examine the possibility of the pool bulk boiling by varying the various parameters, i.e. inter-fuel spacing ratio, heat generation power, and radius of the fuel rod. The application results of this model show that the natural circulation flow through compacted spent fuel bundles enables the pool temperature to control in a safe and effective manner, after the required cooling time. The corresponding acceptance criteria of the cooling time for rearranging the spent fuel rods were also found.

  • PDF

Experimental Study on the Natural Convective Heat Transfer Characteristics of Ferrofluid for Concentric Annuli under Rotating Magnetic Field (회전수 및 자기장강도 변화에 따른 이중원관내 자성유체의 자연대류 열전달 특성에 관한 실험적 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.77-81
    • /
    • 2013
  • The objective of this study is experimentally to investigate natural convective heat transfer characteristics of the ferrofluid for a concentric annuli under rotating magnetic field with variations of the revolution and the magnetic field strength. The rotating magnetic field was provided by induction motor with 6 poles and 3 phases and the revolution and the magnetic field strength were controlled by an inverter driver and a voltage meter, respectively. Temperatures of the inner pipe and the outer pipe in the tested concentric annuli were maintained at $30^{\circ}C$ and $25^{\circ}C$, respectively, during the test and the direction of the rotating magnetic field was a counterclockwise. As a result, the natural convective heat transfer characteristics of the ferrofluid for a concentric annuli were increased with the rise of the revolution and magnetic field strength due to the increased heat dissipation between hot side and cold side of the concentric annuli.

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).

Prediction of Heat-treatment Time of Black Pine Log Damaged by Pine Wilt Disease (소나무재선충병 피해를 받은 곰솔 원목의 열처리 소요시간 예측)

  • Han, Yeonjung;Seo, Yeon-Ok;Jung, Sung-Cheol;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.370-380
    • /
    • 2016
  • The black pine logs damaged by pine wilt disease in Jeju-do were heat-treated to extend the utilization of domestic trees damaged by pine wilt disease. The heat-treatment of wood requires wood to be heated to $56^{\circ}C$ for 30 min at the core. The average moisture content and top-diameter of the black pine logs were ranged from 46% to 141% and from 180 mm to 500 mm, respectively. And the basic specific gravity and oven-dry specific gravity of the black pine logs were 0.47 and 0.52, respectively. The time required for heat-treatment at $105^{\circ}C$ temperature was ranged from 7.7 h to 44.2 h, depending on moisture content and top-diameter. The temperature distribution was used to predict the time required for heat-treatment of black pine log with various moisture contents and top-diameters using finite difference method. The thermal properties of wood including the thermal conductivity and specific heat in accordance with moisture content were calculated. Heat transfer coefficient for mixed convection in form of adding natural convection and forced convection was used for heat transfer analysis. The error between the measured and predicted values ranged from 3% to 45%. The predicted times required for heat-treatment of black pine log with 50% moisture content and 200 mm, 300 mm, and 400 mm top-diameter were 10.9 h, 18.3 h, and 27.0 h, respectively. If the initial moisture content of black pine log is 75%, heat treatment times of 13.6 h, 22.5 h, and 32.8 h were predicted in accordance with top-diameter. And if the initial moisture content of black pine log is 100%, heat treatment times of 16.2 h, 26.5 h, and 38.2 h were predicted in accordance with top-diameter. When the physical properties of logs damaged by pine wilt disease are presented, these results can be applicable to the heat-treatment of red pine and Korean pine logs as well.

Study on Effect of Convection Current Aeration System on Mixing Characteristics and Water Quality of Reservoir (대류식 순환장치의 저수지수체 유동특성 및 수질영향)

  • Lee, Yo-Sang;Lee, Kwang-Man;Koh, Deok-Koo;Yum, Kyung-Taek
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.85-94
    • /
    • 2009
  • This study examines the operational effectiveness of a Convection Current Aeration System (CCAS) in reservoir. CCAS was run from June, 2008 when the thermocline begun forming in the reservoir. This paper reviews the influence of stratification, dissolved oxygen dynamics and temperature in the lake's natural state from June to October 2008. The survey was done on a week basis. Upwelling flow effects a radius of $7{\sim}10m$ at a surface directly and was irrelevant to the strength of thermocline. On the other hand, it was affected the number of working days, and strength of thermocline at vertical profiles of the reservoir. Longer CCAS run, the deeper was the vertical direct flow area. However it didn't break the thermocline during summer season of 2008. The operating efficiency of the CCAS in the reservoir depends on hydraulics and meteological conditions. Computational Fluid Dynamics (CFD) is a very useful tool for evaluating the operating efficiency of fluid dynamics. The geometry for CFD simulation consists of a cylindrical vessel 25 m radius and 40 m height. The CCAS is located in center of domain. The non-uniform tetrahedral meshes had a bulk of the geometry. The meshes ranged from the coarse to the very fine. This is attributed to the cold water flowing into the downcomer and rising, creating a horizontal flow to the top of the CCAS. The result of CFD demonstrate a closer agreement with surveyed data for temperature and flow velocity. Theoretical dispersion volume were calculated at 8m depth, 120 m diameter working for 30 days and 10 m depth, 130 m diameter working for 50 days.

Experimental Study on the Determination of Heat Transfer Coefficient for the KURT (KURT 내 열전달계수 결정에 관한 실험적 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.507-516
    • /
    • 2009
  • In cases of high-level radioactive waste repositories, heat load is apparent by radioactive waste decay. The safety of a waste repository would be influenced by changing circumstances caused by heat transfer through rock. Thus, a ventilation system is necessary to secure the waste repository. The first priority for building an appropriate ventilation system is completing a computer simulation research with thermal rock properties and a heat transfer coefficient. In this study, the heat transfer coefficient in KURT was calculated using the measurement of inner circumstance factors that include dry bulb and wet bulb temperature, rock surface temperature, and barometric pressure. The heater that is 2 m in length and 5 kw in capacity heats the inside of rock in the research module by $90^{\circ}C$. As a result of determining the heat transfer coefficient in the heating section, the changes of heat transfer coefficient were found to be a maximum of 7.9%. The average heat transfer coefficient is approximately 4.533 w/$m^2{\cdot}K$.

Prediction of the Environmental Conditions in Underground Tunnelling Spaces (地下터널 굴착作業場內 作業環境豫測)

  • Park, Hee-Bong
    • Tunnel and Underground Space
    • /
    • v.2 no.1
    • /
    • pp.116-122
    • /
    • 1992
  • A comprehensive, nonsteady state, computer simulation program for the environmental conditions in advancing tunnels (the HEADSIM simulation program) is constructed and successfully validated with heat balance amongst all heat sources, and with mass conservation amongst various airflows including the leakage air from ducts, under timedependent variations of inlet air conditions. which include sudden, diurnal and seasonal changes. Heat conduction in the wall strata and face strata is simulated with most complicated boundary conditions using the finite difference method, and the climatic conditions in roadway sections which contain air ducts, booster fan, spray cooler, compressed air pipes, cold water pipes, return water pipes, machinery and broken rock are simulated taking into account the variations of face operation and the heat storage mechanism in the strata. The limitations of simulation time steps and roadway section lengths are defined according to the stability criteria satisfying the principles of thermodynamics. Variations of heat transfer coefficients, which are newly set, and those of wetness factors are taken into account according to the variations of other parameters and the stepwise advance of the face. Newly-derived formulae are used for computing the air duct leakage and the pressure inside of the duct. A new concept of an 'imaginary duct' is introduced to simulate the climatic conditions in tunnels during holiday periods, which directly affect conditions on subsequent working days under the consideration of natural convection. A subsidiary program (the WALLSIM simulation program) is made to compute the dimensionless tunnel surface temperatures and to compare the results with those from analytical approaches, and to demonstrate the stability, convergence and accuracy of the strata heat conduction simulation, adopting the finite difference method. The WALLSIM also has wide applications, including those for the computation of age coefficients.

  • PDF

ANALYSIS OF HEAT TRANSFER ON SPENT FUEL DRY CASK DURING SHORT-TERM OPERATIONS (사용후핵연료 건식 용기의 단기운영공정 열전달 평가)

  • Kim, H.;Lee, D.G.;Kang, G.U.;Cho, C.H.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • When spent fuel assemblies from the reactor of nuclear power plants(NPPs) are transported, the assemblies are exposed to short-term operations that can affect the peak cladding temperature of spent fuel assemblies. Therefore, it needs to perform the analysis of heat transfer on spent fuel dry cask during the operation. For 3 dimensional computational fluid dynamnics(CFD) simulation, it is proposed that the short-term operation is divided into three processes: Wet, dry, and vacuum drying condition. The three processes have different heat transfer mode and medium. Metal transportation cask, which is Korea Radioactive Waste Agency(KORAD)'s developing cask, is evaluated by the methods proposed in this work. During working hours, the boiling at wet process does not occur in the cask and the peak cladding temperatures of all processes remain below $400^{\circ}C$. The maximum peak cladding temperature is $173.8^{\circ}C$ at vacuum drying process and the temperature rise of dry, and vacuum drying process occurs steeply.