• Title/Summary/Keyword: nano-modified surface

검색결과 235건 처리시간 0.026초

표면형상이 젖음각과 마이크로/나노 트라이볼로지 특성에 미치는 영향 (Effect of surface topography on wetting angle and micro/nano-tribological characteristics)

  • 윤의성;오현진;양승호;공호성
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.25-33
    • /
    • 2002
  • Effect of surface topography on the water wetting nature and micro/nano tribological characteristics of Si-wafer and PTFE was experimentally studied. The ion beam treatment was performed with a hollow cathode ion gun in different argon don dose conditions in a vacuum chamber to change the surface topography, Micro/nano tribological characteristics, water wetting angles and roughness were measured with a micro tribo tester, SPM (scanning prove microscope), contact anglemeter and profilometer, respectively. Results showed that surface roughness increased with the argon ion dose. The water wetting angle of tile ion beam treated samples also increased with the ion dose. Results also showed that micro-adhesion and micro-friction depend on the wetting characteristics of the PTFE samples. However, nano-triboloSical characteristics showed little dependence on the wetting angles. The water wetting characteristics of modified PTFE samples were discussed in terms of the surface topographic characteristics.

  • PDF

개질된 표면을 이용한 풀비등 임계열유속 증진에 관련한 실험적 연구 (Experimental Investigation of CHF Enhancement on the Modified Surface Under Pool Boiling)

  • 강순호;안호선;조항진;김무환;김형모;김준원
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.840-848
    • /
    • 2009
  • In the boiling heat transfer mechanism, CHF(critical heat flux) is the significantly important parameter of the system. So, many researchers have been struggling to enhance the CHF of the system in enormous methods. Recently, there were lots of researches about enormous CHF enhancement with the nanofluids. In that, the pool boiling CHF in nanofluids has the significantly increased value compared to that in pure water because of the deposition of the nanoparticle on the heater surface in the nanofluids. The aim of this study is the comparison of the effect of the nanoparticle deposited surface and the modified surface which has the similar morphology and made by MEMS fabrication. The nanoparticle deposited surface has the complex structures in nano-micro scale. Therefore, we fabricated the surfaces which has the similar wettability and coated with the micro size post and nano structure. The experiment is performed in 3 cases : the bare surface with 0.002% water-ZnO nanofluids, the nanoparticle deposited surface with pure water and the new fabricated surface with pure water. The contact angle, a representative parameter of the wettability, of the all 3 cases has the similar value about 0 and the SEM(scanning electron microscope) images of the surfaces show the complex nano-micro structure. From the pool boiling experiment of the each case, the nanoparticle deposited surface with pure water and the fabricated surface with pure water has the almost same CHF value. In other words, the CHF enhancement of the nanoparticle deposited surface is the surface effect. It also shows that the new fabricated surface follows the nanoparticle deposited surface well.

SPM을 이용한 Si 표면위에 플라즈마 처리된 소수성 박막의 나노 트라이볼로지적 특성 연구 (Nanotribological characteristics of plasma treated hydrophobic thin films on silicon surfaces using SPM)

  • 윤의성;박지현;양승호;한흥구;공호성;고석근
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.35-42
    • /
    • 2001
  • Nanotribological characteristics between a Si$_3$N$_4$ AFM tip and hydrophobic thin films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various ranges of normal load. Plasma-modified thin polymeric films were deposited on Si-wafer (100). Results showed that wetting angle of plasma-modified thin polymeric film increased with the treating time, which resulted in the hydrophobic surface and the decrease of adhesion and friction. Nanotribological characteristics of these surfaces were compared with those of other hydrophobic surfaces, such as DLC, OTS and IBAD-Ag coated surfaces. Those of OTS coated surface was superior to those of others, though wetting angle of plasma-modified thin polymeric film is higher.

  • PDF

소 혈청 알부민이 함유된 유사체액 내에서 아파타이트의 생성에 대한 고분해능 전자현미경 분석 (HREM Analysis of Apatite Formation in Modified-Simulated Body Fluid Containing Bovine Serum Albumin)

  • 김우정;이갑호;홍순익
    • 대한금속재료학회지
    • /
    • 제46권2호
    • /
    • pp.105-110
    • /
    • 2008
  • Process of the hydroxyapatite (HA) formation on bioactive titanium metal prepared by NaOH treatment in a modified-simulated body fluid (mSBF) containing bovine serum albumin (BSA) was investigated by high resolution transmission electron microscope attached with energy dispersive X-ray spectrometer (EDX). The amorphous titanate, which was formed on titanium surface by NaOH treatment, combined with the calcium ions in the liquid to form an amorphous calcium titanite. With increasing of soaking time in the liquid, an amorphous calcium titanite combined with the phosphate ions to form an amorphous calcium phosphate with low Ca/P atomic ratio, and it grows as aggregates of plate (or needle)-like substance on titanium surface. The crystalline apatite layers, which are needle-shaped with the c axis parallel to the long axis, are formed in an amorphous calcium phosphate with further increase in soaking time. The formation of needle-shaped apatite layers can be explained by electrostatic effects and difference of concentration between calcium, phosphate, and albumin ions.

The Band Edge Liminescence of SUrface Modified CdSe Nanocrystallites and Their Applications

  • Lee, Jin-Kyu;Kuno, Masaru K.;Bawendi, Moungi G.
    • Journal of Photoscience
    • /
    • 제5권4호
    • /
    • pp.175-179
    • /
    • 1998
  • In this paper, a brief overview of nanocrystallites of metal and semi-conductor materials will be presented, and then the novel synthetic method of high quality CdSe nanocrystallites developed by Bawendi group at MIT will be introduced . It will be shown that results of optical properties of surface modified nanocrystallites give the evidence that the luminescence of CdSe nanocrystallites is not originated from surface related trap states, but from intrinsic spin forbidden core states. Some of the interesting applications of CdSe nano-crystallites will also be discussed at the end.

  • PDF

습식 표면개질 처리된 폴리이미드 필름 표면의 특성에 관한 연구 (A Study on Characteristics of Surface Modified Polyimide Film by Wet Process)

  • 구석본;이홍기
    • 한국표면공학회지
    • /
    • 제39권4호
    • /
    • pp.166-172
    • /
    • 2006
  • Metallized Polyimide films are extensively used as base materials in microelectronics, optical and automotive applications. However it is difficult to deposit metals on those because of their structural stabilities. In this work, polyimide films are modified by a wet process with alkalinemetalhydroxide and additives to introduce functional groups. The surface molecular structures of polyimide are investigated using X-ray photoelectron spectroscopy(XPS), fourier transform infrared reflection spectroscopy(FTIR-ATR), atomic force micro-scopic(AFM). XPS spectra and FTIR spectra show that the surface structure of polyimide is converted into potassium polyamate. AFM image and AFM cross-sectional analyses reveal the increased roughness on the modified surface of polyimide films. As a result, it is shown that the adhesion strength between polyimide surface and electroless nickel layer is increased by the nano-anchoring effect.

Micro/nano Tribological and Water Wetting Characteristics of Ion Beam Treated PTFE Surfaces

  • Yoon, Eui-Sung;Oh, Hyun-Jin;Yang, Seung-Ho;Kong, Hosung
    • KSTLE International Journal
    • /
    • 제3권1호
    • /
    • pp.12-16
    • /
    • 2002
  • Micro/nano tribological and water wetting characteristics of ion beam treated PTFE (polytetrafluoroethylene) surfaces were experimentally studied. The ion beam treatment was performed with a hollow cathode ion gun at different argon ion dose conditions in a vacuum chamber to modify the topography of PTFE surface. Micro/nano tribological characteristics, water wetting angles and roughness were measured with a micro tribe tester, SPM (scanning probe microscope), contact anglemeter and profilometer, respectively. Results showed that surface roughness increased with the argon ion dose. Water wetting angle of the ion beam treated samples increased with the ion dose, so the surface shows an ultra-hydrophobic nature. Micro-adhesion and micro-friction depend on the wetting characteristics of the PTFE samples. However, nano-tribological characteristics showed different results. The scale effect of surface topography on tribological characteristics was discussed. Also, the water wetting characteristics of modified PTFE samples were discussed in terms of the surface topographic characteristics.