• 제목/요약/키워드: nano-material

검색결과 2,454건 처리시간 0.025초

DEA를 활용한 R&D 프로젝트의 효율성 비교 : 산업기술사업을 중심으로 (Comparing Efficiencies of R&D Projects Using DEA : Focused on Industrial Technology Program)

  • 김흥규;강원진;배진희
    • 산업경영시스템학회지
    • /
    • 제38권3호
    • /
    • pp.29-38
    • /
    • 2015
  • In this paper, scale efficiencies and relative efficiencies of R&D projects in Industrial Technology Program, sponsored by Ministry of Trade, Industry and Energy, Korea, are calculated and compared. For the process, various DEA (Data Envelopment Analysis) models are adopted as major techniques. For DEA, two stage input oriented models are utilized for calculating the efficiencies. Next, the calculated efficiencies are grouped according to their subprograms (Industrial Material, IT Fusion, Nano Fusion, Energy Resources, and Resources Technology) and recipient types (Public Enterprise, Large Enterprise, Medium Enterprise, Small Enterprise, Lab., Univ., and etc.) respectively. Then various subprograms and recipient types are compared in terms of scale efficiencies (CCR models) and relative efficiencies (BCC models). In addition, the correlation between the 1st stage relative efficiencies and the 2nd stage relative efficiencies is calculated, from which the causal relationship between them can be inferred. Statistical analysis shows that the amount of input, in general, should increase in order to be scale efficient (CCR models) regardless of the subprograms and recipient types, that the 1st and 2nd stage relative efficiencies are different in terms of the programs and recipient types (BCC models), and that there is no significant correlation between the 1st stage relative efficiencies and the 2nd stage relative efficiencies. However, the results should be used only as reference because the goal each and every subprogram has is different and the situation each and every recipient type faces is different. In addition, the causal link between the 1st stage relative efficiencies and the 2nd relative efficiencies is not considered, which, in turn, is the limitation of this paper.

Non-uniform Distribution of Magnetic Fluid in Multistage Magnetic Fluid Seals

  • Zhongzhong, Wang;Decai, Li;Jing, Zhou
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.299-305
    • /
    • 2017
  • Magnetic fluid, a new type of magnetic material, is a colloidal liquid constituted of nano-scale ferromagnetic particles suspended in carrier fluid. Magnetic fluid sealing is one of the most successful applications of magnetic fluid. As a new type of seal offering the advantages of no leakage, long life and high reliability, the magnetic fluid seal has been widely utilized under vacuum- and low-pressure-differential conditions. In practical applications, for improved pressure capacity, a multistage sealing structure is always used. However, in engineering applications, a uniform distribution of magnetic fluid under each tooth often cannot be achieved, which problem weakens the overall pressure capacity of the seals. In order to improve the pressure capacity of magnetic fluid seals and broaden their applications, the present study theoretically and experimentally analyzed the degree of non-uniform distribution of multistage magnetic fluid seals. A mathematical model reflecting the relationship between the pressure capacity and the distribution of magnetic fluid under a single tooth was constructed, and a formula showing the relationship between the volume of magnetic fluid and its contact width with the shaft was derived. Furthermore, the relationship of magnetic fluid volume to capacity was analyzed. Thereby, the causes of non-uniform distribution could be verified: injection of magnetic fluid; the assembly of magnetic fluid seals; the change of magnetic fluid silhouette under pressure loading; the magnetic fluid sealing mechanism of pressure transmission, and seal failure. In consideration of these causes, methods to improve the pressure capacity of magnetic fluid seals was devised (and is herein proposed).

고무 복합재료의 압저항 효과 (Rubber Composites with Piezoresistive Effects)

  • 정준호;윤주호;김일;심상은
    • Elastomers and Composites
    • /
    • 제48권1호
    • /
    • pp.76-84
    • /
    • 2013
  • 압저항 효과(piezoresistive effect)는 가해진 외부 압력이나 힘에 의해 전기적 저항이 변하는 것을 말한다. 이러한 압저항 효과는 압력, 진동, 가속 등을 탐지하는 센서에 많이 이용되고 있다. 압저항 효과를 갖는 재료가 많지만 그 중에서도 특히, 전도성 충전제를 첨가한 고무 복합체는 충전제의 종류, 입자 크기, 입자 모양, 입자 종횡비(aspect ratio), 그리고 입자의 양 등을 조절하여 다양한 압력 범위에서의 압저항 효과를 발현할 수 있고, 고무를 기질로 사용함으로써 복합체에 탄성과 유연성을 줄 수 있기 때문에 많은 관심을 받고 있다. 본 논문에서는 압저항 효과의 기본원리 및 다양한 고무 복합체의 압저항 효과에 대해 알아본다.

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

Novel Silica Nanotubes Using a Library of Carbohydrate Gel Assemblies as Templates for Sol-Gel Transcription in Binary Systems

  • Jung, Jong-Hwa;Lee, Shim-Sung;Shinkai, Seiji;Iwaura, Rika;Shimizu, Toshimi
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.63-68
    • /
    • 2004
  • Sugar-based gelator p-dodecanoyl-aminophenyl- ${\beta}$-D-aldopyranosides (1-3) have been shown to self-assemble in the presence of p-aminophenyl aldopyranosides. The hydrogel 1+4 showed the double-helical structure with 3-25 nm outer diameters, which is quite different from that of 1. The gel 2+5 revealed twisted ribbon structure with 30-50 nm in widths and a few micrometers of length whereas the gel 3+4 revealed the single and the bundled fiber structures. The difference in these gel supramolecular structures has successfully been transcribed into silica structures by sol-gel polymerization of tetraethoxysilane (TEOS), resulting in the doublehelical, the twisted-ribbon, the single and the multiple (lotus-shaped) hollow fiber structures. These results indicate that novel silica structures can be created by transcription of various superstructures formed in binary gels through the hydrogen-bonding interaction, and the amino group of the p-aminophenyl aldopyranosides acts as an efficient driving force to create novel silica nanotubes. Furthermore, electron energy-loss spectroscopy (ELLS) provided strong evidence for the inner hollow structure of the double-helical silica nanotube. This is a novel and successful example that a variety of new silica structures can be created using a library of carbohydrate gel fibers as their templates.

Service Life Prediction of Rubber Bushing for Tracked Vehicles

  • Woo, Chang-Su;Kang, In-Sug;Lee, Kang-Suk
    • Elastomers and Composites
    • /
    • 제55권2호
    • /
    • pp.81-87
    • /
    • 2020
  • Service life prediction and evaluation of rubber components is the foundational technology necessary for securing the safety and reliability of the product and to ensure an optimum design. Even though the domestic industry has recognized the importance thereof, technology for a systematic design and analysis of the same has not yet been established. In order to develop this technology, identifying the fatigue damage parameters that affect service life is imperative. Most anti-vibration rubber components had been damaged by repeated load and aging. Hence, the evaluation of the fatigue characteristics is indispensable. Therefore, in this paper, we propose a method that can predict the service life of rubber components relatively accurately in a short period of time. This method works even in the initial designing stage. We followed the service life prediction procedure of the proposed rubber components. The weak part of the rubber and the maximum strain were analyzed using finite element analysis of the rubber bushing for the tracked vehicles. In order to predict the service life of the rubber components that were in storage for a certain period of time, the fatigue test was performed on the three-dimensional dumbbell specimen, based on the results obtained by the rubber material acceleration test. The service life formula of the rubber bushing for tracked vehicles was derived using both finite element analysis and the fatigue test. The service life of the rubber bushing for tracked vehicles was estimated to be about 1.7 million cycles at room temperature (initial stage) and about 400,000 cycles when kept in storage for 3 years. Through this paper, the service life for various rubber parts is expected be predicted and evaluated. This will contribute to improving the durability and reliability of rubber components.

4P 분석을 통한 양자점 기술개발 현황 분석 -양자점 기술의 응용 및 융합 분야를 중심으로 (The Status of Research of Quantum dot Using 4P Analysis -Focusing on the application and convergence field of quantum technology)

  • 허나영;고영주
    • 한국융합학회논문지
    • /
    • 제6권2호
    • /
    • pp.49-55
    • /
    • 2015
  • 양자점 기술은 나노연구 관점에서 벌크 재료에 대한 보완적 응용과 고유한 특성을 활용한 응용의 폭이 넓어 융합기술로서 의미가 크다. 양자점 기술의 발전과 더불어 기술성, 사업성, 시장성에 기반한 현황 분석이 매우 중요하고, 이에 본 연구는 특허, 논문, 시장 및 산업, 국가 R&D 과제 정보를 활용한 4P 분석 방법을 적용하여 양자점 연구의 동향을 파악하고자 한다. 연구의 결과물은 양자점 연구의 방향 설정, 전략 수립에 활용될 수 있는 기초 정보를 제공한다. 특히 특허와 논문 분석을 통해 양자점 연구 성과를 파악하고, 급격한 성장세를 보이는 응용 분야와 사업화를 견인하고 있는 응용 분야를 도출하였다. 또한 선진 연구와 국내 연구 동향을 비교하여 국내 양자점 연구 현황을 진단할 수 있는 초석을 제공하였다는 점에서 본 연구가 의미를 갖는다.

Optimization of SWCNT-Coated Fabric Sensors for Human Joint Motion Sensing

  • Cho, Hyun-Seung;Park, Seon-Hyung;Yang, Jin-Hee;Park, Su-Youn;Han, Bo-Ram;Kim, Jin-Sun;Lee, Hae-Dong;Lee, Kang-Hwi;Lee, Jeong-Whan;Kang, Bok-Ku;Chon, Chang-Soo;Kim, Han-Sung;Lee, Joo-Hyeon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2059-2066
    • /
    • 2018
  • This study explored the feasibility of utilizing an SWCNT-coated fabric sensor for the development of a wearable motion sensing device. The extent of variation in electric resistance of the sensor material was evaluated by varying the fiber composition of the SWCNT-coated base fabrics, attachment methods, number of layers, and sensor width and length. 32 sensors were fabricated by employing different combinations of these variables. Using a custom-built experimental jig, the amount of voltage change in a fabric sensor as a function of the length was measured as the fabric sensors underwent loading-unloading test with induced strains of 30 %, 40 %, and 50 % at a frequency of 0.5 Hz. First-step analysis revealed the following: characteristics of the strain-voltage curves of the fabric sensors confirmed that 14 out of 32 sensors were evaluated as more suitable for measuring human joint movement, as they yield stable resistance values under tension-release conditions; furthermore, significantly stable resistance values were observed at each level of strain. Secondly, we analyzed the averaged maximum, minimum, and standard deviations at various strain levels. From this analysis, it was determined that the two-layer sensor structure and welding attachment method contributed to the improvement of sensing accuracy.

하이브리드 선형이온원에 의한 유압 기어펌프용 Cr-DLC코팅막의 특성과 효율성능 (Coatings Properties and Efficiency Performance of Cr-DLC Films Deposited by Hybrid Linear Ion Source for Hydraulic Gear Pump)

  • 차순용;김왕렬;박민석;권세훈;정원섭;강명창
    • 한국분말재료학회지
    • /
    • 제17권6호
    • /
    • pp.456-463
    • /
    • 2010
  • This paper describes the results of the application of Cr-Diamond-like carbon (DLC) films for efficiency improvement through surface modification of spur gear parts in the hydraulic gear pump. Cr-DLC films were successfully deposited on SCM 415 substrates by a hybrid coating process using linear ion source (LIS) and magnetron sputtering method. The characteristics of the films were systematically investigated using FE-SEM, nano-indentation, sliding tester and AFM instrument. The microstructure of Cr-DLC films turned into the dense and fine grains with relatively preferred orientation. The thickness formed in our Cr buffer layer and DLC coating layer were obtained the 487 nm and $1.14\;{\mu}m$. The average friction coefficient of Cr-DLC films considerably decreased to 0.15 for 0.50 of uncoated SCM415 material. The hardness and surface roughness of Cr-DLC films were measured 20 GPa and 10.76 nm, respectively. And then, efficiency tests were performed on the hydraulic gear pump to investigate the efficiency performance of the Cr-DLC coated spur gear. The experimental results show that the volumetric and mechanical efficiency of hydraulic gear pump using the Cr-DLC spur gear were improved up to 2~5% and better efficiency improvement could be attributed to its excellent microstructure, higher hardness, and lower friction coefficient. This conclusion proves the feasibility in the efficiency improvement of hydraulic gear pump for industrial applications.

의약품 제조공정에서의 전사적 품질혁신을 위한 공정분석기술 개발 (Development of Process Analytical Technology (PAT) for Total Quality Innovation on Pharmaceutical Processes)

  • 신상문;박경진;최용선;이상길;최광진;권병수
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권6호
    • /
    • pp.329-338
    • /
    • 2007
  • The quality assurance issue of drug products is more important than the general product because it is highly related to the human health and life. In this reason, the regulatory guide lines have continuously been intensified all around the world. In order to achieve effective quality assurance and real-time product release (RTPR) of drug products, process analytical technology (PAT), which can analyze and control a manufacturing process, has been proposed from the United States. With the PAT process, we can obtain significant process features of materials, quality characteristics and product capabilities from a raw material to the final product in the real-time procedure. PAT can also be utilized to process validation using information system that can analyze the risk of drug products through out an entire product life-cycle. In this paper, we first offered a new concept for the off-line process design methods to prepare the improved quality assurance restrictions and a real-time control method by establishing an information system. We also introduced an automatic inspection system by obtaining surrogate variables based on drug product formulations. Finally, we proposed an advanced PAT concept using validation and feedback principles through out the entire life-cycle of drug product manufacturing processes.