• Title/Summary/Keyword: n-Decane

Search Result 92, Processing Time 0.029 seconds

Measurement and Prediction of Autoignition Temperature of n-Butanol + n-Decane System (n-Butanol과 n-Decane계의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong;Hong, Soo-Kang
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.184-189
    • /
    • 2011
  • This study measured the AITs of n-butanol + n-decane system from ignition delay time (time lag) by using ASTM E659 apparatus. The AITs of n-butanol and n-decane which constituted binary system were $340^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-butanol + n-decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation).

Determination of Flash Point for n-Octane+n-Nonane and n-Nonane+n-Decane Systems by Seta flash Apparatus (Seta flash 장치에 의한 n-Octane + n-Nonane계 및 n-Nonane + n-Decane계의 인화점 결정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.11-17
    • /
    • 2020
  • In order to guarantee safe storage and transportation of a flammable liquid solution, it is very important to know its flash point information. In this paper, flash points of n-octane+n-nonane system and n-nonane+n-decane system were measured by Seta flash apparatus and an empirical equation is proposed for the accurate estimation of flash point. Empirical equation is used to predict flash point of n-octane+n-nonane system and n-nonane+n-decane system, which were also compared to Unifac-based model. Absolute average errors of flash point data predicted by Unifac-based model are 0.7℃ and 0.6℃ for n-octane+n-nonane system and n-nonane+n-decane system, respectively. Absolute average errors of flash point data predicted by empirical equation are 0.2℃ and 0.4℃ for n-octane+n-nonane system and n-nonane+n-decane system, respectively. In conclusion, empirical equation proposed in this paper, presented the most satisfactory.

Prediction of Autoignition Temperature of n-Decane and sec-Butanol Mixture (n-Decane과 sec-Butanol 혼합물의 최소자연발화온도의 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.85-90
    • /
    • 2012
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the material will spontaneously ignite. The AIT is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs of n-Decane+sec-Butanol system by using ASTM E659 apparatus. The AITs of n-Decane and sec-Butanol which constituted binary system were $212^{\circ}C$ and $447^{\circ}C$, respectively. The experimental AITs of n-Decane+sec-Butanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation).

The Minimum Autoignition Temperature Behavior(MAITB) of n-Decane and Acetic acid Mixture (n-Decane과 Acetic acid 혼합물의 최소자연발화온도 거동)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • The autoignition temperature(AIT) is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs and ignition delay time for n-Decane and Acetic acid system by using ASTM E659 apparatus. The AITs of n-Decane and Acetic acid which constituted binary system were $212^{\circ}C$ and $512^{\circ}C$, respectively. The experimental AITs of n-Decane and Acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). And n-Decane and Acetic acid system was shown the minimum autoignition temperature behavior(MAITB).

Flash Point Calculation for n-Octane+n-Decane and n-Octane+n-Dodecane by UNIFAC Group Contribution Model (UNIFAC 그룹 기여 모델에 의한 n-Octnae+n-Decane 계와 n-Octane+n-Dodecane 계의 인화점 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.86-91
    • /
    • 2015
  • The flash point is used to categorize inflammable liquids according to their relative flammability. Such a categorization is important for the safe handling, storage, and transportation of inflammable liquids. The flash point temperature of two binary liquid mixtures(n-octane+n-decane and n-octane+n-dodecane) has been measured for the entire concentration range using Seta-flash closed cup tester based on the ASTM D3278 method. The closed cup flash point temperature was estimated using the UNIFAC(Universal Functional Activity Coefficient) group contribution model. The experimentally derived flash point was also compared with the predicted flash point from the UNIFAC model. The UNIFAC model is able to estimate the flash point fairly well for n-octane+n-decane mixture and n-octane+n-dodecane mixture.

Calculation and Measurement of Flash Point for n-Decane + n-Octanol and Acetic Acid + n-Butanol Using a Tag-Open-Cup Apparatus (Tag 개방식 장치를 활용한 n-Decane + n-Octanol계 및 Acetic Acid + n-Butanol계의 인화점 측정과 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.45-50
    • /
    • 2015
  • The flash point is one of the most important properties for characterizing the fire and explosion hazard of liquid solutions. In this study, a Tag open-cup apparatus was used to measure the flash points of two flammable binary mixtures, n-decane + n-octanol and acetic acid + n-butanol. The flash point temperature was estimated using the UNIFAC (Universal Functional Activity Coefficient) group contribution model and optimization method. The experimentally derived flash point was also compared with the predicted flash point. The two methods can estimate the flash point fairly well for the n-decane + n-octanol and acetic acid + n-butanol systems.

Measurement and Prediction of Autoignition Temperature of n-Propanol+n-Decane Mixture (노말프로판올과 노말데칸 혼합물의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.55-61
    • /
    • 2014
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the substance will spontaneously ignite in the absence of an external ignition source such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for processs safety. This study measured the AITs of n-Propanol+n-Decane system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-Propanol and n-Decane which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-Propanol+n-Decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D(average absolute deviation).

Measurement of Lower Flash Point for Ternary Mixture, n-Nonane+n-Decane+n-Dodecane System (삼성분계 혼합물인 n-Nonane+n-Decane+n-Dodecane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.31-36
    • /
    • 2016
  • The flash point is one of the most important indicators of the flammability of liquid solutions. The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. In this study the flash points of ternary liquid solutions, n-nonane+n-decane+n-dodecane system, were measured using Seta flash closed cup tester. The measured values were compared with the calculated values using Raoult's law and empirical equation. The calculated data by empirical equation described the measured values more effectively than those calculated by Raoult's law.

Solubilization of Mixture of Hydrocarbon Oils by C12E8 Nonionic Surfactant Solution (C12E8 비이온 계면활성제 수용액에 의한 탄화수소 오일 혼합물의 가용화 특성에 관한 연구)

  • Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.59-65
    • /
    • 2008
  • The equilibrium solubilization capacity of the mixture of hydrocarbon oils by $C_{12}E_8$ nonionic surfactant micellar solution was measured at $23^{\circ}C$ by gas chromatography (GC) analysis. Experimental results indicated that the solubilization capacity for pure alkanes was found to decrease almost linearly with the alkane carbon number (ACN) of the hydrocarbon oil. For the binary mixture systems of the hydrocarbon oils both selective and nonselective solubilization behaviors were observed depending on the difference in ACN of the two hydrocarbon oils. Equilibrium solubilization tests for the hydrocarbon oil mixtures in $C_{12}E_8$ surfactant solutions such as the three n-octane/n-nonane, n-nonane/n-decane and n-decane/n-undecane mixture systems suggest almost non-selective solubilization. On the other hand, the n-octane/n-decane and n-octane/n-undecane systems, where difference in ACN of the two hydrocarbon oils is greater than 1, selective solubilization in favor of n-octane was conclusively demonstrated.

A Twenty-Eight Days Inhalation Toxicity Study of N-decane in Sprague Dawley Rats (SD흰쥐를 이용한 n-decane의 28일 반복흡입독성연구)

  • Rim Kyung Taek;Kim Hyeon Young;Song Kyung Seuk;Chung Yong Hyun;Chang Hee Kyung;Han Jeong Hee;Lee Sung Bae;Chun Yoon Seok;Lee Yong Mook;Yu Il Je
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.4
    • /
    • pp.345-352
    • /
    • 2004
  • N-decane은 지방족탄화수소로 다른 탄환수소들과 같이 혼합된 형태로 존재하며 페인트 제거제나 드라이 크리닝 제품에 사용된다. 최근의 본 연구팀이 실시한 전자산업계의 MSDS 신뢰성조사 결과에 따르면 세정제의 사용 경향은 과거의 방향족 탄화수소나 CFC. HCFC에서 $C_{10}$이상의 지방족탄화수소 물질로 변화되고 있는 경향을 보여주었다. Stoddard solvent나 나프타 같은 탄화수소 혼합물에 대한 작업 환경노출기준은 설정되어있지만 n-decane에 대해서는 제한적인 독성자료 밖에 없으며 작업환경노출기준은 설정되어 있지 않다. 따라서 작업환경에 대한 적절한 관리기준제시와 독성학적 자료를 제공하기 위해 n-decane을 28일 반복 흡입독성시험을 실시하였다. 6주령 흰쥐로 체중이 229$\pm$10g되는 숫컷과 165$\pm$7g되는 암컷 흰쥐를 4개 용량군 즉 대조군, 저농도군(50ppm), 중농도군(200ppm), 고농도군(800ppm) (각군당 10마리)으로 설정하여 하루 6시간, 주5일로 4주간 흡입쳄버에서 노출시켰다. 28일간 노출 후 n-decane의 노출용량에 따른 암수의 체중에는 유의한 변화가 없었으며 유의한 혈액학적 생화학적 변화도 발견되지 않았다. 고농도로 노출된 수컷 몇 마리에서 고환 세정관에서의 공포화(vacuolization)가 발견되었으나, 간신장, 비장, 폐, 부신, 심장, 뇌 등 다른 장기에 대한 조직병리학적 검사에서는 뚜렷한 조직병리학적인 변화를 발견할 수 없었다.