• Title/Summary/Keyword: muscles fatigue

Search Result 189, Processing Time 0.026 seconds

Effect of Dietary Supplementation of Two Tonic Formula on the Forced-Swimming Capacity of Rats (자양강장용 기능성 식품이 흰쥐의 강제수영 능력에 미치는 영향)

  • Song, Tae-Cheol;Han, Dae-Seok;Lee, Chang-Ho;Kim, Young-Eon;Jung, Kyung-Ah;Kim, Hae-Yeong
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.648-655
    • /
    • 2005
  • Effects of two types of formula designed for commercial product on forced-swimming capacity and related biochemical parameters of Sprague-Dawley rats were evaluated. Treatment groups were fed diet supplemented with 4.56% formula A (EFA: exercise-trained and formula A-supplemented group) or B (EFB: exercise-trained and formula B-supplemented group) for 4 weeks. All groups were regularly trained twice a week to be accustomed to swimming. After 4 weeks, each group was divided into two subgroups: 90 min swimming (90-min subgroups) and swimming until exhaustion (all-out subgroups). Serum was collected, and skeletal muscles were dissected out after swimming. Forced-swimming time until exhaustion was significantly longer (p<0.05) in EFA and EFB groups than that of exercised control group. Among 90-min subgroups, serum ammonia level of EFB group was significantly lower than that of exercised control group (p<0.05). Among all-out subgroups, serum lactate levels were not significantly different among exercised control and treatment groups, whereas serum-free fatty acid levels of EFA and EFB groups were significantly lower than that of exercised control group (p<0.05). In conclusion, EFA and EFB groups enhanced forced swimming capacity of rats by increasing fat utilization and delaying accumulation of serum fatigue factor.

A Convergence Study on Changes in the Muscle Activity around the Neck of the Operator according to the Patient's Head Angle at the Direct Visual Inspection of the Maxillary Right-side Molar Palatal Surface (상악 우측 대구치 구개면의 직접 시진 시 환자 머리 각도에 따른 술자의 목 주변 근육활성도 변화의 융합적 연구)

  • Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.209-216
    • /
    • 2018
  • This study aimed to investigate the association of the muscle activity around the neck of the operator(dental hygienists') according to the change in the patient's neck angle during a direct visual inspection on the maxillary right-side molar palatal surface. The operators were $4^{th}$ year dental hygiene students, who are future dentalhy gienists, having accurate understanding on and awareness of the location of the operation site, hand fixation, and how to use the tools. Data on the change in the muscle activity around the neck were collected by using surface electromyography and neck goniometer. SPSS statistics 20 was used for statistical analyses including Shapiro-wilk test and one-way ANOVA. As a result, the activities of the operator upper trapezius, cervical erector spinae, and levator scapulae muscles significantly decreased when the patient's head was angled compared to when it was not. For the angle of the operator head, the head bend significantly decreased when the patient's head was angled than when it was not. Based on the study results, it is expected that angling the patient's head when treating his or her teeth will decrease the excessive muscle activity around the neck of the operator, and will reduce muscle fatigue. Therefore, angling the head of the patient while treating his or her teeth is recommended. This suggests that muscle pain caused by repetitive actions in the wrong posture can be reduced.

Comparison of Chin Tuck Against Resistance and Shaker Exercise on Suprahyoid and Sternocleidomastoid Muscle Activity in Stroke Older Patients with Dysphagia (삼킴 장애가 있는 뇌졸중 노인 환자에서 저항성 고개 숙이기 운동과 Shaker 운동의 목뿔위 및 목빗근 활성 비교)

  • Kim, Bon Yi;Lee, Seul;Moon, Jong Hoon;Won, Young Sik
    • 재활복지
    • /
    • v.20 no.3
    • /
    • pp.179-193
    • /
    • 2016
  • Chin Tuck Against Resistance Exercise(CTARE) and Shaker exercise is used to common for strengthening of suprahyoid muscle. No previous studies was compare of two exercises for patients with dyaphagia. This study investigated the effects of CTARE and Shaker exercise on suprahyoid, sternocleidomastoid muscle activity in stroke older patients with dysphagia. Ten stroke patients with dyaphagia voluntarily participated in this study. All subjects was performed in the order in the CTARE (isometric, isokinetic), Shaker (isometric, isokinetic), and repeated each ten trials. After CTARE was performed, subjects took a 5 min wash out period to minimize muscle fatigue. Activity of suprahyoid and sternocleidomastoid muscle during two training was analyzed using surface electromyography(sEMG). Wilcoxon signed rank test was used to assess differecences for muscles activity between the effects of the CTAR and Shaker exercise within group. CTARE and Shaker exercise showed no significant difference activity in suprahyoid muscle(p > .05). CTARE showed significantly lower muscle activity in sternocleidomastoid muscle than Shaker exercise(p < .05). CTARE in stroke older patients with dysphagia may be a effective intervention to improve swallowing function than Shaker exercise.

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

Study of BiJeung by 18 doctors - Study of II - (18인(人)의 비증(痺證) 논술(論述)에 대(對)한 연구(硏究) - 《비증전집(痺證專輯)》 에 대(對)한 연구(硏究) II -)

  • Sohn, Dong Woo;Oh, Min Suk
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.595-646
    • /
    • 2000
  • I. Introduction Bi(痺) means blocking. BiJeung is one kind of symptoms making muscles, bones and jonts feel pain, numbness or edema. For example it can be gout or SLE etc. says that Bi is combination of PungHanSeup. And many doctors said that BiJeung is caused by food, fatigue, sex, stress and change of weather. Therefore we must treat BiJeung by character of patients and characteristic of the disease. Many famous doctors studied medical science by their fathers or teachers. So the history of medical science is long. So I studied ${\ll}Bijeungjujip{\gg}$. II. Final Decision 1. JoGeumTak(趙金鐸) devided BiJeung into Pung, Han, Seup and EumHeo, HeulHeo, YangHeo, GanSinHeo by charcter or reaction of pain. And he use DaeJinGyoTang, GyegiGakYakJiMoTang, SamyoSan, etc. 2. JangPaeGyeu(張沛圭) focused on division of HanYeol(寒熱; coldness and heat) in spite of complexity of BiJeung. He also used insects for treatment. They are very useful for treatment of BiJeung because they can remove EoHyeol(瘀血). 3. SeolMaeng(薛盟) said that the actual cause of BiJeung is Seup. So he thought that BiJeung can be divided into PungSeup, SeupYeol, HanSeup. And he established 6 rules to treat BiJeung and he studied herbs. 4. JangGi(張琪) introduced 10 prescriptions and 10 rules to cure BiJeung. The 1st prescription is for OyeSa, 2nd for internal Yeol, 3rd for old BiJeung, 4th for Soothing muscles, 5th for HanSeup, 6th for regular BiJeung, 7th for functional disorder, 8th for YeolBi, 9th for joint pain and 10th for pain of lower limb. 5. GangSeYoung(江世英) used PungYeongTang(風靈湯) for the treatment of PungBi, OGyeHeukHoTang(烏桂黑虎湯) for HanBi, BangGiMokGwaTang(防己木瓜湯) for SeupBi, YeolBiTang(熱痺湯) for YeolBi, WoDaeRyeokTang(牛大力湯) for GiHei, HyeolPungGeunTang(血楓根湯) for HyeolHeo, ToJiRyongTang(土地龍湯) for the acute stage of SeupBi, OJoRyongTang(五爪龍湯) for the chronic stage of SeupBi, and so on. 6. ShiGeumMook(施今墨) devided BiJeung into four types. They are PungSeupYeol, PungHanSeup, GiHyeolSil(氣血實) and GiHyeolHeo(氣血虛). And he introduced the eight rules of the treatment(SanPun(散風), ChukHan(逐寒), GeoSeuP(, CheongYeol(淸熱), TongRak(通絡), HwalHyeol(活血), HaengGi(行氣), BoHeo(補虛)). 7. WangYiYou(王李儒) explained the acute athritis and said that it can be applicable to HaneBi(行痺). And he used GyeJiJakYakJiMoTang(桂枝芍蘂知母湯) for HanBi and YeolBiJinTongTang(熱痺鎭痛湯) for YeolBi. 8. JangJinYeo(章眞如) said that YeolBi is more common than HanBi. The sympthoms of YeolBi are severe pain, fever, dried tongue, insomnia, etc. And he devided YeolBi into SilYeol and HeoYeol. In case of SilYeol, he used GyeoJiTangHapBaekHoTang(桂枝湯合白虎湯) and in case of HeoYeol he used JaEumYangAekTang(滋陰養液湯). 9. SaHaeJu(謝海洲) introduced three important rules of treatment and four appropriate rules of treatment of BiJeung. 10. YouDoJu(劉渡舟) said that YeolBi is more common than HanBi. He used GaGamMokBanGiTang(加減木防已湯) for YeolBi, GyeJiJakYakJiMoTang or GyeJiBuJaTang(桂枝附子湯) for HanBi and WooHwangHwan(牛黃丸) for the joint pain. 11. GangYiSon(江爾遜) focused on the internal cause. The most important internal cause is JeongGiHeo(正氣虛). So he tried to treat BiJeung by means of balance of Gi and Hyeol. So he ususlly used ODuTang(烏頭湯) and SamHwangTang(三黃湯) for YeolBi, OJeokSan(五積散) for HanBi, SamBiTang(三痺湯) for the chronic BiJeung. 12. HoGeonHwa(胡建華) said that to distinguish YeolBi from Hanbi is very difficult. So he used GyeJiJakYakJiMoTang in case of mixture of HanBi and YeoBi. 13. PiBokGo(畢福高) said that the most common BiJeung is HanBi. He usually used acupuncture with medicine. He followed the theory of EumYongHwa(嚴用和)-he focused on SeonBoHuSa(先補後瀉). 14. ChoiMunBin(崔文彬) used GeoPungHwalHyeolTang(祛風活血湯) for HanBi, SanHanTongRakTang(散寒通絡湯) for TongBi(痛痺), LiSeupHwaRakTang(利濕和絡湯) for ChakBi(着痺), CheongYeolTongGyeolChukBiTang(淸熱通經逐痺湯) for YeolBi(熱痺) and GeoPungHwalHyeolTang(祛風活血湯) for PiBi(皮痺). 15. YouleokSeon(劉赤選) introduced the common principle for the treatment of BiJeung. He used HaePuneDeungTang(海風藤湯) for HaengBi(行痺), SinChakTang(腎着湯), DokHwalGiSaengTang(獨活寄生湯) for TongBi(痛痺), TongPungBang(痛風方) for ChakBi(着痺) and SangGiYiMiTangGaYeongYangGakTang(桑枝苡米湯加羚羊角骨) for YeolBi(熱痺). 16. LimHakHwa(林鶴和) said about TanTan(movement disorders or numbness) and devided TanTan into the acute stage and the chronic stage. He used acupuncture at the meridian spot like YeolGyeol(列缺), HapGok(合谷), etc. And he also used MaHwangBuJaSeSinTang(麻黃附子細辛湯) in case of the acute stage. In the chronic stage he used BangPungTang(防風湯). 17. JinBaekGeun(陳伯勤) liked to use three rules(HwaHyeol(活血), ChiDam(治痰), BoSin(補腎)) to treat BiJeung. He used JinTongSan(鎭痛散) for the purpose of HwalHyeol(活血), SoHwalRakDan(小活絡丹) for ChiDam(治痰) and DokHwalGiSaengTang(獨活寄生湯) for BoSin(補腎). 18. YimGyeHak(任繼學) focused on YangHyeolJoGi(養血調氣) if the stage of BiJeung is chronic. And in the chronic stage he insisted on not using GalHwal(羌活), DokHwal(獨活) and BangPung(防風).

  • PDF

A study on knowledge, self-efficacy and compliance in Reumatic arthritis Patients (류마티스 관절염 환자의 지식, 자기효능감 및 치료이행과의 관계연구)

  • Kim, Soon-Bong
    • Journal of muscle and joint health
    • /
    • v.5 no.2
    • /
    • pp.238-252
    • /
    • 1998
  • Reumatic arthritis is a disease with joint pain being one of the key symptoms. The patient suffers from the pain, stiff sensation and edema due to the inflammation taking Place In one or more joints. Accompanying these problems are fatigue, unusual exhaustion, fever, tachycardia and weakness. Inaddition, joints are often deformed and muscles shrink along with the progress of edema, coupled with depression and psychological instability resulting from the loss of the mobile function and limitations on the daily life. Some patients become fed up with the long and hard flight with the disease and just give up, which aggravates the symptoms. Others come to the hospital only when the conditions have become serious. We need to prevent these and guide the patients in the right direction. Against this backdrop, this study aims to look into the relations between the knowledge on the part of the patients together with their feeling of self-efficacy and the compliance. The results are expected to help the patients improve their life, In addition to providing useful materials for setting up appropriate plan for nursing intervention. The study was conducted by distributing questionnaire to 88 patients selected from the out-patient department of a university hospital in Inchon, from April 6 to 27, 1998. The following tools were used the yardstick of self-efficacy, developed in 1997 by the Society for the Health of Rheumatism Patients, was used for measuring the levels of knowledge and the feeling of self-efficacy. The degree of compliance was measured by the data collected from documents in addition to the results of the analysis of the interviews with the patients. The reliability of the tools was confirmed. In the analysis, the general characteristics were expressed in figures and percentages. The levels of knowledge, feeling of self-efficacy, and compliance were expressed in the average values and standard deviations. The relations among the variables following the general characteristics were analysed by the t-test and one-way ANOVA. The Pearson correction coefficient was used for the analysis of factors. Multiple-loop analysis was used to identify the variables affecting the compliance. The following are the results of this study. 1. Among the 88 patients, 18 were men and the remaining 70 were women, with a ratio 1 : 3.87. Regarding the age groups, 23 were between 50 and 59 years old, with those between 50 and 69 accounting for 51.1% of the total. High school graduates or higher amounted to 58%. Religious patients was 67% or 59 persons. Fifty nine percent were unemployed, and 58.3% (49 persons) had two children or fewer. The period of suffering from rheumatism varied between 2 months and IS years, with 70% less than years. 2. The average figure In relation to the of knowledge was 17.63 points over 30 or 58. 76%, which means a medium level. 3. The average figure of the feeling of self-efficacy was 60.06 points. 4. The level of compliance was 3.26, which was above average. 5. The relation between the feeling of self-efficacy and compliance showed an "r" value of 0.37, which was significant. It means that the higher the feeling, the greater the compliance points. 6. The analysis of the knowledge level revealed that the difference is found only between the college graduates and junior-high graduates or lower. 7. The feeling of self-efficacy varied along with the age and education level. 8. The general characteristics of patients as discussed above did not show significant difference with the compliance. 9. Regarding the elements influencing the compliance, the number of children, period of suffering, income, age, feering of self-efficacy, knowledge, and compliance had 54% of significance. In conclusion, rheumatism victims can lead a better life if they are appropriately educated, based on efficient training program from the early days of the disease ; if they become able to manage themselves thanks to the training ; and if they are helped by a program focusing on the increase of the feeling of self-efficacy aimed at changing patient's behavior.

  • PDF

Effect of Fermented Cirsium japonicum Extract on Testosterone Deficiency Syndrome (엉겅퀴 발효 추출물을 통한 남성 갱년기 증상 개선 효과)

  • Jeong, Byung Seo;Kim, Seong Hoon;Kim, Hyun Pyo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.7
    • /
    • pp.790-800
    • /
    • 2017
  • As men get older, total testosterone levels decline gradually, and concentrations of free and bioavailable testosterone decline sharply with each decade beyond their 30s. Andropause or testosterone deficiency syndrome (TDS) is defined as a decrease in sexual satisfaction or decline in general well-being accompanied by low levels of testosterone in older men. This male climacteric is characterized by nervousness, reduced potency, decreased libido, irritability, fatigue, depression, memory problems, sleep disturbances, and hot flushes. Cirsium japonicum (CJ) is used as a traditional medicine for hemorrhage, blood congestion, and inflammation in Korea. However, there is no report on the efficacy of CJ treatment for TDS. In this study, we observed the mitigating effect of CJ extract (CE) and fermented CJ extract (FCE) on symptoms of TDS. In elderly male rats, total and testosterone levels, hind limbs muscles, forced swimming time, and total and motile sperm counts significantly increased after daily intake of CE and FCE for 6 weeks. In contrast, sex hormone binding globulin, retroperitoneal fat, total serum cholesterol, and triglyceride levels were significantly reduced in CE and FCE groups. However, there was no difference in prostate specific antigen, aspartate aminotransferase, and alanine aminotransferase levels among all groups, which means CE and FCE did not have putative adverse effects. In a cell experiment, we also observed that CE and FCE enhanced expression of genes related to testosterone biosynthesis but reduced genes involved in testosterone conversion. On the whole, these positive effects on TDS were greater in FCE compared to CE. Thus, these results suggest the potential of FCE as a promising natural product for recovering testosterone levels and alleviating TDS.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF