• Title/Summary/Keyword: multiple-story building

Search Result 46, Processing Time 0.021 seconds

Non-linear Time History Analyses of a Piloti-type Building Structure (필로티형 건물의 비선형 시간이력해석)

  • Lee, Han-Seon;Ko, Dong-Woo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.169-176
    • /
    • 2005
  • Many RC building structures of multiple uses constructed in Korea have the irregularities of torsion and soft story at bottom stories. A typical irregular building was selected as prototype and shaking table tests were performed to investigate the seismic performance of this building. The objective of this study is to evaluate the correlation between the experimental and analytical responses of this irregular building structure subjected to the earthquake excitation by using OpenSees(Open System for Earthquake Engineering Simulation). The results of analyses simulate well the effect of axial forces on the shear force of column and axial deformation. However, some discrepancy between analytical and experimental results in the distribution of shear forces and overturning deformation were observed.

  • PDF

Adhesion Strength Properties of Tile Modules Exposed to Freeze-Thaw Environment (동결융해 환경에 노출된 타일 모듈의 부착강도 특성)

  • Pyeon, Su-Jeong;Kim, Gyu-Yong;Choi, Byung-Cheol;Kim, Moon-Kyu;Eu, Ha-Min;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.217-218
    • /
    • 2023
  • In modern architecture, tiles are used as a decorative material to enhance the appearance of buildings. However, defects occurring during tile installation affect not only the appearance of the building, but also its maintenance. This study aims to investigate stable tile installation by producing tile modules using the floating mortar method and conducting freeze-thaw tests to measure their adhesion strength. Test results showed that the adhesion strength increased as the mesh size decreased, except for S3 mesh. This study highlights the importance of research on tile installation to solve problems related to building appearance and maintenance.

  • PDF

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

Modal Combination Method for Prediction of Story Earthquake Load Profiles (층지진하중분포 예측을 위한 모드조합법)

  • Eom, Tae-Sung;Lee, Hye-Lin;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.65-75
    • /
    • 2006
  • Nonlinear pushover analysis is used to evaluate the earthquake response of building structures. To accurately predict the inelastic response of a structure, the prescribed story load profile should be able to describe the earthquake force profile which actually occurs during the time-history response of the structure. In the present study, a new modal combination method was developed to predict the earthquake load profiles of building structures. In the proposed method, multiple story load profiles are predicted by combining the modal spectrum responses multiplied by the modal combination factors. Parametric studies were performed far moment-resisting frames and walls. Based on the results. the modal combination factors were determined according to the hierarchy of each mode affecting the dynamic responses of structures. The proposed modal combination method was applied to prototype buildings with and without vertical irregularity. The results showed that the proposed method predicts the actual story load profiles which occur during the time-history responses of the structures.

A Development of an Intelligent CAD Engine to Support Architectural Design Collaboration (건축설계의 협동작업을 지원하는 지능형 CAD 엔진의 개발)

  • 최진원
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1997
  • Current CAD systems used in the AEC community have some critical problems. One of them is that they hardly support design collaboration. Thus designers and engineers are hard to transfer design knowledge from one discipline to another. What we need is a common building database which creates and manages building plans/models and relevant design knowledge consistently and effectively. This paper presents a powerful CAD editor, called UNIFORM, which is being developed. Currently UNIFORM includes three main modules: a plan generator, a 3-D model generator, and component databases. A plan generator, called UNIFORM PLANNER, creates a plan which contains semantically-rich information of building. Each component in the plan can be presented in various ways and connected to component databases that contain knowledge of building components such as windows, doors, walls, etc. Based on the plan UNIFORM MODELER, another module of the program, generates a three dimensional building model which could be a multiple-story building. One of the main ideas behind the system is that it generates and maintains a common building form that can be easily delivered to other members of the project team. Thus it is expected to increase system integration, team interactions, and productivity.

  • PDF

Structural Parameters and Modeling Technique for Prediction of Dynamic Response of a One-story Building with a Flexible Diaphragm (유연한 지붕을 갖는 단층 건물의 동적응답 예측을 위한 해석모델링 방법과 구조변수의 설정)

  • ;Donald W. White
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.271-280
    • /
    • 2003
  • The purpose of the study presented in this paper is to develope the general model for capture of the linear and nonlinear response of a flexible diaphragm building in which there are significant contributions from the out-of-plane walls. Two single-story single-diaphragm half scale reinforced masonry buildings were tested by researchers at the United States Army Construction Engineering Research Laboratory (CERL). The first had a metal deck diaphragm. The second specimen had a diaphragm with a single layer of diagonal lumber sheathing, A multiple degree of freedom (MDOF) approach is adopted in this paper. The required stiffnesses and strengths of the components within this model are determined.

Design Eccentricity of RC Building Structures with Torsional Irregularity (비틀림 비정형성을 가진 RC 건물의 설계편심)

  • 이한선;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.140-143
    • /
    • 2003
  • Recently, many high-rise reinforced concrete (RC) bearing wall structures of multiple occupancy have been constructed, which have the irregularities of weak (or soft) story and torsion at the lower stories simultaneously. The study compared the eccentricity of such a building predicted by design codes, EC 8, IBC 2000 and UBC 97, and by the test results through a series of shaking table tests of 1:12 model. Based on the comparison of the predicted eccentricity and the test result, the conclusions are drawn as follow: Accidental torsion due to the uncertainty on the properties of structure can be reasonably predicted by using the dynamic analysis with the center of mass being shifted by 5 percent of the dimension of the building perpendicular to the direction of the excitations than by using equivalent lateral force procedure

  • PDF

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

Wind-Induced Vibration Control of a Tall Building Using Magneto-Rheological Dampers: A Feasibility Study

  • Gu, Ja-In;Kim, Saang-Bum;Yun, Chung-Bang;Kim, Yun-Seok
    • Computational Structural Engineering : An International Journal
    • /
    • v.3 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • A recently developed semi-active control system employing magneto-rheological (MR) fluid dampers is applied to vibration control of a wind excited tall building. The semi-active control system with MR fluid dampers appears to have the reliability of passive control devices and the adaptability of fully active control systems. The system requires only small power source, which is critical during severe events, when the main power source may fail. Numerical simulation studies are performed to demonstrate the efficiency of the MR dampers on the third ASCE benchmark problem. Multiple MR dampers are assumed to be installed in the 76-story building. Genetic algorithm is applied to determine the optimal locations and capacities of the MR dampers. Clipped optimal controller is designed to control the MR dampers based on the acceleration feedback. To verify the robustness with respect to the variation of the external wind force, several cases with different wind forces are considered in the numerical simulation. Simulation results show that the semi-actively controlled MR dampers can effectively reduce both the peak and RMS responses the tall building under various wind force conditions. The control performance of the MR dampers for wind is found to be fairly similar to the performance of an active tuned mass damper.

  • PDF

BUILDING INFORMATION MODELING (BIM)-BASED DESIGN OF ENERGY EFFICIENT BUILDINGS

  • Cho, Chung-Suk;Chen, Don;Woo, Sungkwon
    • Journal of KIBIM
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • With the increased awareness of energy consumption as well as the environmental impact of building operations, architects, designers and planners are required to place more consideration on sustainability and energy performance of the building. To ensure most of those considerations are reflected in the building performance, critical design decisions should be made by key stakeholders early during the design development stage. The application of BIM during building energy simulations has profoundly improved the energy analysis process and thus this approach has gained momentum. However, despite rapid advances in BIM-based processes, the question still remains how ordinary building stakeholders can perform energy performance analysis, which has previously been conducted predominantly by professionals, to maximize energy efficient building performance. To address this issue, we identified two leading building performance analysis software programs, Energy Plus and IES (IES ), and compared their effectiveness and suitability as BIM-based energy simulation tools. To facilitate this study, we examined a case study on Building Performance Model (BPM) of a single story building with one door, multiple windows on each wall, a slab and a roof. We focused particularly on building energy performance by differing building orientation and window sizes and compared how effectively these two software programs analyzed the performance. We also looked at typical decision-making processes implementing building energy simulation program during the early design stages in the U.S. Finally, conclusions were drawn as to how to conduct BIM-based building energy performance evaluations more efficiently. Suggestions for further avenues of research are also made.