• Title/Summary/Keyword: multiple simultaneous monitoring

Search Result 62, Processing Time 0.024 seconds

Development of a WLAN Based Monitoring System for Group Activity Measurement in Real-Time

  • Tsunoda, Hiroshi;Nakayama, Hidehisa;Ohta, Kohei;Suzuki, Akihiro;Nishiyama, Hiroki;Nagatomi, Ryoichi;Hashimoto, Kazuo;Waizumi, Yuji;Keeni, Glenn Mansfield;Nemoto, Yoshiaki
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.86-94
    • /
    • 2011
  • In recent years, there has been a rise in epidemiological evidence suggesting the health benefits of a physically active lifestyle. However, it is not always easy for individuals to personally recognize the optimal conditions for exercise and physical activity. Wearable acceleration-based pedometers have become widely used in estimating the amount of physical activity, and to a limited extent, providing information regarding exercise intensity, but they have never been used to assess adaptation to exercise. In order to realize simultaneous activity monitoring for multiple users exercising outdoors, we developed a prototype wireless local area network (WLAN) based system. In our system, a WLAN is deployed outside, and a user wearing a smart phone and monitoring device exercises freely within the coverage area of the wireless network. By doing so, the developed system is able to monitor the activity of each user andmeasures various parameters including those related to exercise adaptation. In a demonstration experiment, the developed system was evaluated and used to monitor users enjoying a Nordic walk, after which users were immediately able to receive their exercise report. In this paper, we discuss the requirements and issues in developing an activity monitoring system and report the findings we obtained through the demonstration experiment.

Multiple-Hypothesis RAIM Algorithm with an RRAIM Concept (RRAIM 기법을 활용한 다중 가설 사용자 무결성 감시 알고리듬)

  • Yun, Ho;Kee, Changdon
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.593-601
    • /
    • 2012
  • This paper develops and analyzes a new multiple-hypothesis Receiver Autonomous Integrity Monitoring (RAIM) algorithm as a candidate for future standard architecture. The proposed algorithm can handle simultaneous multiple failures as well as a single failure. It uses measurement residuals and satellite observation matrices of several consecutive epochs for Failure Detection and Exclusion (FDE). The proposed algorithm redueces the Minimum Detectable Bias (MDB) via the Relative RAIM (RRAIM) scheme. Simulation results show that the proposed algorithm can detect and filter out multiple failures in tens of meters.

A Simultaneous Real-Time Heart Rate Monitoring System for Multiple Users (다수 이용자를 위한 동시적 실시간 심박수 모니터링 시스템)

  • Ha, Sangho
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.8
    • /
    • pp.253-258
    • /
    • 2015
  • From the point of view of u-healthcare, heart rate is so useful for both illness for taking care of patients and wellness for improving the level of health and wellbeing. It is because heart rate is a significant clinical variable for all kinds of diseases as well as an indicator of the intensity of exercise. Recently, a number of various wearable heart rate monitors have been released to check people's status in the body by monitoring their heart rates. In addition, a number of smartphone applications have been released to conveniently monitor the status of exercise by using heart rate monitors. However, all of these applications are limited to a personal usage. In this paper, we will design a system to simultaneously monitor heart rates coming from multiple users in a real-time, and develop an Android application to apply the system. The application mainly features a simultaneous monitoring of heart rates coming from multiple users, allowing to be effectively applied to fitness centers.

Profiling Analysis of Sphingolipids in HL-60 Cells by High-Performance Liquid Chromatography-Tandem Mass Spectrometry in combination with Multiple Reaction Monitoring

  • Son, Jung-Hyun;Lee, Jae-Ick;Yang, Ryung;Kim, Dong-Hyun
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.288.3-289
    • /
    • 2003
  • Sphingolipid species are important second messengers due to their role in the mitogenesis, differentiation and apoptosis. We developed a new column liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) in combination with multiple reaction monitoring (MRM) method for the rapid, simultaneous and quantitative determination of unambiguous detecting sphingolipids in cell culture of human cancer cells (HL-60). (omitted)

  • PDF

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Damage assessment of shear-type structures under varying mass effects

  • Do, Ngoan T.;Mei, Qipei;Gul, Mustafa
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.3
    • /
    • pp.237-254
    • /
    • 2019
  • This paper presents an improved time series based damage detection approach with experimental verifications for detection, localization, and quantification of damage in shear-type structures under varying mass effects using output-only vibration data. The proposed method can be very effective for automated monitoring of buildings to develop proactive maintenance strategies. In this method, Auto-Regressive Moving Average models with eXogenous inputs (ARMAX) are built to represent the dynamic relationship of different sensor clusters. The damage features are extracted based on the relative difference of the ARMAX model coefficients to identify the existence, location and severity of damage of stiffness and mass separately. The results from a laboratory-scale shear type structure show that different damage scenarios are revealed successfully using the approach. At the end of this paper, the methodology limitations are also discussed, especially when simultaneous occurrence of mass and stiffness damage at multiple locations.

Simultaneous Determination of Benzoic Acid, Caffeic Acid and Chlorogenic Acid in Seeds of Eriobotrya japonica and their Antibacterial Effect

  • Jeong, Jun-Mo;Lee, Kyoung-In;Kim, Sun-Min
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.1
    • /
    • pp.89-93
    • /
    • 2014
  • We aim to develop a simple method for simultaneous and quantitative determination of benzoic acid, caffeic acid and chlorogenic acid in seeds of Eriobotrya japonica. In addition, antibacterial effect of these three phenolic acids was examined. A basic method is performed on the high performance liquid chromatography system coupled to an UV-detector (230 nm) and reverse phase C-18 column ($4.6{\times}150mm$, $5{\mu}m$). Each phenolic acid was confirmed via liquid chromatography-mass spectrometry (MS)/MS system under the multiple-reaction monitoring with negative-ion electrospray ionization (ESI(-)) mode. It is demonstrated that the method was could be applied to samples for an analytical study of the phenolic acids. On the other hand, three phenolic acids in seeds of E. japonica exhibited antibacterial effect against several pathogenic bacteria. Of these, benzoic acid was found to have stronger antibacterial effect.

Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS (LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석)

  • Shin, Sang-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2010
  • A new method for the simultaneous determination of six glucocorticoids (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, and flumethasone) in meats (bovine muscle, bovine liver) were established. Samples were effectively extracted using C18 cartridge with ethylacetate. Chromatographic separation was achieved using C18 column and negative electrospray ionization mass spectrometry was performed in the Multiple Reaction Monitoring mode for the effective quantitation and qualification of glucocorticoids. Acetonitrile and water (0.1% formic acid) were used as mobile phase and additive for effective electrospray ionization, and gave good chromatographic separation and mass spectrometric sensitivity. The limit of detection (LODs) and the limit of quantitation (LOQs) in spiked blank samples depending on types of matrix and pharmaceuticals were ranged from 0.2 to $1.0\;{\mu}g$/kg and 0.8 to $3.4\;{\mu}g$/kg, respectively. And the recoveries were between 89.5 to 119.6%. The established method showed good recoveries, accuracies, precisions and fast sample preparation and it will be applied to assay of glucocorticoids residues in meat.

Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010 (IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3100-3106
    • /
    • 2014
  • This paper develops power measurement system with multiple sensor input channels (voltage-8 channels and current-10 channels) that simultaneously can monitor power components for both supply and load side of power system. The hardware implementation of the proposed system is based on TMS320C42 DSP and signal processing program algorithm to calculate power components use the definition of IEEE Standard 1459-2010 related power quality. The performance of the developed system is tested by using standard ac power source device, and the test results showed that accuracy of the developed system is less than 0.2 %. Also, field test of the proposed system in the three-phase and four-wire power system was implemented. Simultaneous multiple channel measurement and analysis of power components in commercial and industrial electrical power system using the proposed system will be necessary to reduce power quality problems.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.