Browse > Article
http://dx.doi.org/10.5668/JEHS.2021.47.1.64

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs  

Cha, Sangwon (Department of Chemistry, Dongguk University-Seoul Campus)
Oh, Eunha (Life & Environment Science center, Seegene Medical Foundation)
Oh, Selim (Institute for Life & Environmental Technology, Smartive Corporation)
Han, Sang Beom (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Im, Hosub (Institute for Life & Environmental Technology, Smartive Corporation)
Publication Information
Journal of Environmental Health Sciences / v.47, no.1, 2021 , pp. 64-77 More about this Journal
Abstract
Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.
Keywords
Whole blood metals; bio-monitoring; ICP-MS; multi-simultaneous analysis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 National Institute of Environmental Reserch. Environmental test/inspection QA/QC handbook. 2011. NIER NO. 2011-08-1294.
2 Ministry of Food and Drug Safety. Guideline on bioanalytical method validation. 11-1471000-000028-01; 2013. P.40.
3 National Institute of Environmental Research. A manual for analysis of environmental pollutants in the human specimen. NIER GOVP1200717001; 2006. P.302.
4 Kong KA. Statistical methods: reliability assessment and method comparison. Ewha Med J. 2017; 40(1): 9-16.   DOI
5 Becker K, Schulz C, Kaus S, Seiwert M, Seifert B. German Environmental Survey 1998 (GerES III): environmental pollutants in the urine of the German population. Int J Hyg Environ Health. 2003; 206(1): 15-24.   DOI
6 Fukui Y, Ohashi F, Sakuragi S, Moriguchi J, Ikeda M. Comparative evaluation of GF-AAS and ICP-MS for analyses of cadmium in blood. Ind Health. 2011; 49(3): 338-343.   DOI
7 Lee W, Hur YH, Park KS. A study of analytical method for trace metal ions in whole blood and urine by inductively coupled plasma-mass spectrometry using solid-liquid extraction technique. Anal Sci Technol. 1998; 11(4): 281-291.
8 Kim YH, Kim WI, Hwang SR, Song KB, Park JS, Kang YY, et al. Establishment of analytical methods for blood and urine using ICP-MS (II). Environmental Health Risk Research Department. NIER 2009-01-1057; 2009. P. 62.
9 Lee SY, Oh HJ, Choi YH, Kim JW, Kim SH. Trace metal analysis using inductively plasma-mass spectrometry (ICP-MS). Korean J Lab. 2004; 24: 362-370.
10 Trzcinka-Ochocka M, Brodzka R, Janasik B. Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters. J Clin Lab Anal. 2016; 30(2): 130-139.   DOI
11 DeBord DG, Carreon T, Lentz TJ, Middendorf PJ, Hoover MD, Schulte PA. Use of the "Exposome" in the Practice of Epidemiology: A Primer on -Omic Technologies. Am J Epidemiol. 2016; 184(4): 302-314.   DOI
12 Palmer CD, Lewis Jr ME, Geraghty CM, Barbosa Jr F, Parsons PJ. Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry. Spectrochimica Acta Part B. 2006; 61: 980-990.   DOI
13 Lee JY, KIM JH, Choi DW, Lee DW, Park JH, Yoon HJ, Pyo HS, Kwon HJ, Park KS. The Association of Heavy metal of Blood and Serum in the Alzheimer's Diseases. Official Journal of Korean Society of Toxicology. 2012; 28(2): 93-98.
14 Lee JH, Lee CK, Moon CS, Choi IJ, Lee KJ, Yi SM, et al. Korea National Survey for environmental pollutants in the human body 2008: heavy metals in the blood urine of the Korean population. Int J Environ Health. 2012; 215(4): 449-457.   DOI
15 Nico Laur, Ralf Kinscherf, Karolina Pomytkin, Lars Kaiser, Otto Knes, Hans-Peter Deigner. ICP-MS teace element analysis in serum and whole blood. PLoS ONE. 2020; 15(5): e0233357. https://doi.org/10.1371/journal.pone.0233357.   DOI
16 Angerer J, Aylward LL, Hays SM, Heinzow B, Wilhelm M. Human biomonitoring assessment values: approaches and data requirements. Int J Hyg Environ Health. 2011; 214(5): 348-360.   DOI
17 Kim S. Application of biomonitoring to activities on environmental health and recommendations for Korean National Environmental Health Survey. The Korean Journal of Public Health. 2015; 52(1): 59-74.
18 Park C, Yu SD. Status and prospects of the Korean National Environmental Health Survey (KoNEHS). J Environ Health Sci. 2014; 40(1): 1-9.   DOI
19 Haines DA, Saravanabhavan G, Werry K, Khoury C. An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019. Int J Hyg Environ Health. 2017; 220(2 Pt A): 13-28.   DOI
20 Becker K, Conrad A, Kirsch N, Kolossa-Gehring M, Schulz C, Seiwert M, et al. German Environmental Survey (GerES): human biomonitoring as a tool to identify exposure pathways. Int J Hyg Environ Health. 2007; 210(3-4): 267-269.   DOI
21 Deanna RJ, Jeffery M, Denis ST, Melanie F, Neva JM, Kristen LW, C.Derrick QJ, Kathleen LC, Robert LJ. Analysis of whole humna blood for Pb, Cd, Hg, Se and Mn by ICP-DRC-MS for biomonitoring and acute exposures. Talanta. 2017; 1(162): 114-122.
22 Awata H, Linder S, Mitchell LE, Delclos GL. Biomarker Levels of Toxic Metals among Asian Populations in the United States: NHANES 2011-2012. Environ Health Perspect. 2017; 125(3): 306-313.   DOI
23 Butler O, Evans H, Fisher A, Hill S, Harrinton C, et al. Atomic spectrometry updates: a 25-year retrospective. J Anal At Spectrom. 2010; 25(10): 1546-1566.   DOI
24 Fukui Y, Ohashi F, Sakuragi S, Moriguchi J, Ikeda M. Comparative evaluation of GF-AAS and ICP-MS for analyses of cadmium in blood. Ind Health. 2011; 49(3): 338-343.   DOI
25 Vriens A, Nawrot TS, Janssen BG, Baeyens W, Bruckers L, Covaci A, et al. Exposure to Environmental Pollutants and Their Association with Biomarkers of Aging: A Multipollutant Approach. Environ Sci Technol. 2019; doi: 10.1021/acs.est/8b07141. [Epub ahead of print]   DOI
26 Goulle JP, Saussereau E, Mahieu L, Guerbet M. Current role of ICP-MS in clinical toxicology and forensic toxicology: a metallic profile. Bioanalysis. 2014; 6(17): 2245-2259.   DOI
27 Haines DA, Saravanabhavan G, Werry K, Khoury C. An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019. Int J Hyg Environ Health. 2017; 220(2 Pt A): 13-28.   DOI
28 Kwon JY, Kim BG, Lim HJ, Seo JW, Kang MK, Kim YM, et al. Comparison of human blood cadmium concentrations using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS). J Environ Health Sci. 2018; 44(5): 491-501.
29 Goulle JP, Mahieu L, Castermant J, Neveu N, Bonneau L, Laine G, et al. Metal and metalloid multielementary ICP-MS validation in whole blood, plasma, urine and hair. Reference values. Forensic Sci Int. 2005; 153(1): 39-44.   DOI
30 Caldwell KL, Hartel J, Jarrett J, Jones RL. Inductively coupled plasma mass spectrometry to measure multiple toxic elements in urine in NHANES 1999-2000. Atomic Spectroscopy. 2005; 26(1): 1-7.
31 McShane WJ, Pappas RS, Wilson-McElprang V, Paschal D. A rugged and transferable methodfor determining blood cadmium, mercury, and lead with inductively coupled plasma-massspectrometry, Spectrochim. Acta Part B:- At. Spectrosc. 2008; 63: 638-644.   DOI
32 Caldwell KL, Mortensen ME, Jones RL, Caudill SP, Osterloh JD. Total blood mercuryconcentrations in the US population: 1999-2006. Int. J. Hyg. Environ. Health. 2009; 212: 588-598. [PubMed: 19481974]   DOI
33 CDC (Centers for Disease Control and Prevention). Laboratory Procedure Manual-Cadmium, Lead, Managanse, Mercury, and Selenium. Blood Metals Panel 3 (BMP3) ICP-DRC-MS. CDC Method NO. DLS 3016.8.04