• 제목/요약/키워드: multi-mode design

검색결과 461건 처리시간 0.024초

Experimental Results of New Ion Source for Performance Test

  • 김태성;정승호;장두희;이광원;인상열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

복합재료 트러스 교량시스템의 정적거동 및 파괴모드에 관한 해석적 연구 (Study of Failure Mode and Static Behavior of Lightweight FRP Truss Bridge Deck System)

  • 정우영;이형길
    • 한국전산구조공학회논문집
    • /
    • 제20권5호
    • /
    • pp.511-520
    • /
    • 2007
  • 본 연구는 복합재료 교량시스템의 규준 정립을 위한 연구로서 실제 설계 시공되어진 복합재료 교량의 정밀해석수행과 이를 통한 복합재료 교량의 파괴거동 및 설계기준 등을 조사하는데 그 목적이 있다. 본 연구의 효율적인 연구를 위하여 실제 미국 NEW YORK주 내에 설계 시공되어있는 Noncomposite-FRP 복합재료 교량을 대상으로 해석적 연구를 수행하였으며 본 연구에서 사용된 해석적 모델을 토대로 실제 미국에서 기 수행되어진 교량 거동에 관한 해석 및 실험하중 평가와 그 결과를 비교하였다. 특히 국내 복합재료 교량의 해석적 설계기준 평가를 위하여 보다 실질적이고 정확한 파괴모드의 조사 및 분석이 요구되어지므로 본 연구에서는 이를 위하여 기존의 해석적 연구에서 가벼운 중량으로 인하여 무시되었던 자중의 영향과 각 적층 layer에 설계된 ply orientation을 고려하여 해석하였다. 그 결과 자중을 고려한 복합재료 패널들의 경우, 제작 결함에 따른 이음부 파괴가 없을 경우 교량 상부 구조 중 횡축 보에서의 국부 좌굴 파괴가 교량의 파괴를 지배할 것으로 본 연구결과에서 예측되었다. 이는 복합재료 교량 제작 시 복합재료 상판 패널과 보의 이음부가 Noncomposite로 제작되는 경우 실제 제작되어진 복합재료 상판의 고 강성에 의하여 재하 하중에 의한 하부 강재 거더 좌굴이 선행되는 것으로 판단된다.

사용자 선택에 따른 자유 시점 비디오 서비스 기반의 통합 플레이어 시스템 구현 (Implementation of Integrated Player System based on Free-Viewpoint Video Service according to User Selection)

  • 양지희;송민기;박구만
    • 방송공학회논문지
    • /
    • 제25권2호
    • /
    • pp.265-274
    • /
    • 2020
  • 자유 시점 비디오 서비스는 사용자와의 상호작용을 통해 원하는 임의의 각도나 위치, 거리에서 시청할 수 있게 하는 기술이다. 본 논문에서는 사용자가 선택하여 시청할 수 있는 자유 시점 비디오 서비스를 Inward view, Outward view, 3D object view, First person view의 네 가지 시청 모드로 정의하였으며 하나의 플레이어에서 시청이 가능한 새로운 통합 프로그램을 개발 및 구현하였다. 아이돌 공연과 농구 경기 콘텐츠에 대해 각 시청 모드에 적합한 다시점 카메라를 설치하여 데이터를 확보하였으며, 서버에 저장된 데이터가 네트워크를 통해 스트리밍 됨으로써 시청이 가능하도록 하였다. 사용자는 자유롭게 네 가지의 시청 모드와 공간상의 위치, 각도 등을 선택할 수 있으며, 선택된 시점에 맞는 영상과 음향이 렌더링 되어 통합 플레이어에 표출된다. 이는 기존의 자유 시점 비디오 서비스를 포함한 다양한 시청 형태를 결합함으로써 사용자에게 몰입감과 현장감을 제공할 수 있을 뿐만 아니라 확장성이 있는 자유 시점 비디오 서비스 플레이어가 될 것으로 기대된다.

디지털 홀로그램의 보안을 위한 고성능 암호화기의 하드웨어 구조 (Hardware Architecture of High Performance Cipher for Security of Digital Hologram)

  • 서영호;유지상;김동욱
    • 방송공학회논문지
    • /
    • 제17권2호
    • /
    • pp.374-387
    • /
    • 2012
  • 본 논문에서는 이산 웨이블릿 패킷 변환을 이용하여 디지털 홀로그램의 중요 성분을 추적하고 암호화하는 알고리즘을 위한 하드웨어를 구현하였다. 웨이블릿 변환과 부대역의 패킷화를 이용한 암호화 방법을 이용하고, 적용된 암호화 기법은 웨이블릿 변환의 레벨과 에너지 값을 선택함으로써 다양한 강도로 암호화가 가능하다. 디지털 홀로그램의 암호화는 크게 두 부분으로 구성되는데 첫 번째는 웨이블릿 변환을 수행하는 것이고, 두 번째는 암호화를 수행하는 것이다. 고속의 웨이블릿 변환을 하드웨어로 구현하기 위해서 리프팅 기반의 하드웨어 구조를 제안하고, 다양한 암호화를 수행하기 위해서는 다중모드를 가지는 블록암호시스템의 구조를 제안한다. 동일한 구조의 반복적인 연산을 통해서 수행되는 리프팅의 특성을 이용하여 단위 연산을 수행할 수 있는 셀을 제안하고 이를 확장하여 전체 리프팅 하드웨어를 구성하였다. 블록 암호시스템의 구성을 위해서 AES, SEED, 그리고 3DES의 블록암호화 알고리즘을 사용하였고 데이터를 최소의 대기시간(최소 128클록, 최대 256클록)만을 가지면서 실시간으로 데이터를 암호화 혹은 복호화시킬 수 있다. 디지털 홀로그램은 전체 데이터 중에서 단지 0.032%의 데이터만을 암호화되더라도 객체를 분간할 수 없었다. 또한 구현된 하드웨어는 $0.25{\mu}m$ CMOS 공정에서 약 20만 게이트의 자원을 사용하였고, 타이밍 시뮬레이션 결과에서 살펴볼 때 약 165MHz의 클록속도에서 안정적으로 동작할 수 있었다.

DCT-기반 영상/비디오 보안을 위한 암호화 기법 및 하드웨어 구현 (Ciphering Scheme and Hardware Implementation for MPEG-based Image/Video Security)

  • 박성호;최현준;서영호;김동욱
    • 대한전자공학회논문지SP
    • /
    • 제42권2호
    • /
    • pp.27-36
    • /
    • 2005
  • 년 논문에서는 MPEG과 JPEG, H.26X 계열 등의 DCT-기반 영상/비디오 컨텐츠에 효과적인 암호화 방법을 제안하였고, 이를 최적화된 하드웨어로 구현하여 고속동작이 가능하도록 하였다. 영상/비디오의 압축, 복원 및 암호화로 인한 많은 연산량을 고려하여 영상의 중요한 정보(DC 및 DPCM계수)만을 암호화 대상 데이터로 선정하여 부분 암호화를 수행하였다. 그 결과 암호화에 소요되는 비용은 원 영상 전체를 암호화하는 비용이 감소하였다. 여기서 Nf는 GOP내의 프레임수이고 PI는 B와 P 프레임에 존재하는 인트라 매크로블록의 수이다. 암호화 알고리즘으로는 다중모드 AES, DES, 그리고 SEED를 선택적으로 사용할 수 있도록 하였다. 제안한 암호화 방법은 C++로 구현한 소프트웨어와 TM-5를 사용하여 약 1,000개의 영상을 대상으로 실험하였다 그 결과 부분 암호화된 영상으로부터 원 영상을 추측할 수 없어 암호화 효과가 충분함을 확인하였으며, 이 때 암호화에 의한 압축률 감소율은 $1.6\%$에 불과하였다. Verilog-HDL로 구현한 하드웨어 암호화 시스템은 하이닉스 $0.25{\mu}m$ CMOS 팬텀-셀 라이브러리를 사용하여 SynopsysTM의 디자인 컴파일러로 합성함으로써 게이트-수준 회로를 구하였다. 타이밍 시뮬레이션은 CadenceTM의 Verilog-XL을 이용해서 수행한 결과 100MHz 이상의 동자 주파수에서 안정적으로 동작함을 확인하였다. 따라서 제안된 암호화 방법 및 구현된 하드웨어는 현재 중요한 문제로 대두되고 있는 종단간(end-to-end) 보안에 대한 좋은 해결책으로 유용하게 사용될 수 있으리라 기대된다.

차세대 이동통신 시스템에 PAPR 감소기법을 적용한 다항식 사전왜곡 기법에 관한 연구 (A Study on Polynomial Pre-Distortion Technique Using PAPR Reduction Method in the Next Generation Mobile Communication System)

  • 김완태;박기식;조성준
    • 한국항행학회논문지
    • /
    • 제14권5호
    • /
    • pp.684-690
    • /
    • 2010
  • 차세대 이동통신 시스템은 다양한 서비스의 융합과 멀티모드를 지원하기 위한 구조로 연구되고 있다. 또한 다양한 서비스를 제공받기 위한 사용자의 요구는 점차 증가되고 있으며, 서비스 지원을 위한 대용량 데이터 전송을 위한 많은 통신방식들이 출현하고 있다. 그 중 대표적인 시스템으로 OFDM(Orthogonal Frequency Division Multiplexing) 방식을 이용하는 WiBro(Wireless Broadband), WLAN(Wireless Local Area Network) 등이 있다. 하지만 차세대 이동통신 시스템에서는 하나의 단말로 OFDM 방식을 이용한 통신방식 이외 CDMA(Code Division Multiple Access), WCDMA(Wideband CDMA) 방식을 동시에 지원 받고자한다. 통합된 시스템은 SoC(System on Chip) 기술 적용으로 빠른 발전을 이루고 있지만, 무선통신 시스템에서 필수적으로 요구되는 요소 중 전력 증폭기의 비선형 특성으로 인한 신호의 왜곡을 유발시켜 인접채널 간섭을 성화 시키고 시스템의 효율을 떨어뜨리는 문제를 해결해야 한다. 전력증폭기의 문제점을 해결하기 위해 많은 선형화 기법들이 제시되었으며, 다항식 사전왜곡 기법은 증폭기로 입력되는 신호가 증폭기의 역 특성을 갖도록 하는 기법으로 다항식을 통하여 증폭기를 모델링하기 때문에 수렴 속도가 빠르고 다른 기법들과 비교하여 우수한 성능을 보인다. 본 논문에서는 차세대 이동통신 서비스를 위한 모뎀 구조를 제시하고 OFDM 방식 사용에 있어 발생 되는 PAPR(Peak-to-Average Power Ratio) 감소 기법을 적용한 후 다항식 사전왜곡 기법을 적용하여 차세대 이동통신 시스템을 분석하였다.

필로티형 고층 RC건물의 비선형시간이력해석 (Non-linear Time History Analysis of Piloti-Type High-rise RC Buildings)

  • 고동우;이한선
    • 한국지진공학회논문집
    • /
    • 제13권1호
    • /
    • pp.35-43
    • /
    • 2009
  • 강한 지진에 대한 필로티형 고층 철근콘크리트 건물의 거동을 묘사하기 위한 해석기법의 개발과 성능평가를 위해, 상부벽식 하부 골조형식인 필로티형 건물에 대한 1/12축소 진동대 실험결과와 OpenSees를 이용하여 실험모델에 대한 비선형 시간이력해석을 수행한 결과를 비교하였다. 하부골조 형식은 모두 골조로 이루어진 형태(BF)와 전단벽이 한쪽 외부골조에 치우쳐 비틀림이 발생하는 형태(ESW)의 실험체에 대해 해석연구를 수행하였다. 철근과 콘크리트의 응력-변형률관계를 정의한 후 이를 단면에 이식시킨 섬유모델을 통해 비선형거동을 나타내도록 하였으며, 벽체는 MVLEM모델을 이용하였다. 해석결과 본 논문에서 제시한 비선형 모델은 필로티층의 거동(예를 들면 필로티층의 항복강도와 강성 상부구조물의 흔들림, 거동, 그리고 축력의 변화에 따른 축강성과 전단강성의 변화)을 비교적 정확하게 묘사하였다. 그러나 MVLEM으로 벽체의 비선형거동을 구성한 결과 거시거동은 실제 모델을 잘 따랐으나, 비틀림이 주된 진동주기일 때 발생하는 벽체 횡강성의 급격한 증가와 Warping현상으로 인해 코너기둥에 발생하는 과도한 인장력은 제대로 반영하지 못하였다. 비선형 해석으로 설계부재력을 구할 경우 실제보다 약 $20{\sim}30%$ 작게 나타났는데, 이는 실험과 해석방법의 차이때문에 발생한 것으로 보이며, 비선형 거동이 과도하게 발생한 수준의 지진에 대해서는 필로티형 건물의 거동특성을 충실히 나타내었다.

2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계 (A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter)

  • 김영신;김성근;부영건;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제47권2호
    • /
    • pp.21-31
    • /
    • 2010
  • 본 논문에서는 DisplayPort용 전자기기 또는 클록 발생을 요구하는 다양한 회로에서 발생 할 수 있는 전자방해(EMI) 현상을 줄일 수 있는 위상 동기 루프와 확산 대역 클록 발생기를 구현 하였다. 이 시스템은 기본적으로 송신용 위상 동기 루프와 확산 대역 클록 발생기 구현을 위한 전하펌프2 와 기준주파수 분주기 등으로 구성된다. 본 논문에서는 2.7Gbps/1.62Gbps DisplayPort 응용 회로에 적합 하도록 10개의 다중 위상 신호를 출력 할 수 있는 270MHz/162MHz 듀얼 모드 위상 동기 루프를 설계 하였고 추가적으로 1.35GHz/810MHz의 위상 동기 루프를 설계하여 지터를 크게 감소시킬 수 있는 구조를 제안하였다. 270MHz/162MHz 위상 동기 루프와 5:1 시리얼라이저 2개, 그리고 1.35GHz 위상 동기 루프와 2:1 시리얼라이저를 연동함으로써 지터 성분을 크게 줄일 수 있다. 위상 동기 루프에서 사용 된 주파수 전환 다중위상 전압제어 발진기와 더불어 DisplayPort 규격에 맞는 주파수 전환이 가능 하도록 분주기를 공유하고 50% duty ratio를 보장할 수 있는 주파수 분주기 구조를 제안 하였다. 또한, 지터를 줄이기 위해서 출력전류 오차를 크게 줄일 수 있는 전하펌프 구조를 제안 하였다. 0.13 um CMOS 공정을 사용하여 설계 하였으며, 270MHz/162MHz PLL의 칩 면적은 $650um\;{\times}\;500um$ 이고, 1.35GHz/810MHz PLL의 칩 면적은 $600um\;{\times}\;500um$ 이다. 270MHz/162MHz 위상 동기 루프 전압제어 발진기의 조절 범위는 330MHz이고, 위상 잡음은 1MHz 오프셋에서 -114cBc/Hz, 확산대역 클록 발생기의 확산 진폭도 는 0.5%이고, 변조 주파수는 31kHz이다. 전체 전력 소모는 48mW이다.

ICT 의료시설 기반에서 종사자의 소방안전 지식과 대처방법 인식수준 (ICT Medical Service Provider's Knowledge and level of recognizing how to cope with fire fighting safety)

  • 김자숙;김자옥;안영준
    • 한국전자통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.51-60
    • /
    • 2014
  • 본 연구는 광주 전남지역 ICT 의료시설 기반에서 종사자를 대상으로 소방안전 지식과 대처방법 인식수준의 정도를 파악하고 차이를 조사하여 ICT 의료시설 기반에서 소방안전 대처방법 교육 매뉴얼의 기초자료를 제공하기 위하여 수행 되었다. 자료는 SPSS Win 14.0을 사용하여 분석하였다. 연구결과 ICT 의료시설 기반에서 종사자의 소방안전 지식은 10점 만점에 7.06점, 소방 대처방법 인식수준은 11점 만점에 6.61점이었다. ICT 의료시설 기반에서 종사자의 일반적 특성과 소방안전 대처방법 인식수준을 분석한 결과 성별(t=4.12, p<.001, 연령(${\chi}^2$=17.24, p<.001), 근무경력(${\chi}^2$=22.76, p<.001), 소방안전교육 경험 유무(t=6.10, p<.001), 소방안전에 대한 본인의 주관적 지식정도(${\chi}^2$=53.83, p<.001)에서 통계적으로 유의한 차이가 있었다. 따라서 ICT 의료시설 기반에서 종사자의 소방안전 대처를 증진하기 위해서는 강의 중심의 지식 전달 교육을 지양하고, 자기 주도적 학습, 개인별 맞춤학습, 협동 학습을 강조하는 다양한 콘텐츠 개발을 통한 실무 체험 중심의 소방안전 교육, 시뮬레이션을 이용한 환자분류체계별 배치와 광역 화재감지를 위한 적외선 레이저 연기검출, 다중포인트 통신 프로토콜에 의한 디지털 화재 방지 모니터링 시스템, 영상기반 화재검출, 화재감지를 위한 로봇 설계 및 테이터 처리등의 다학문적인 접근을 통한 ICT 의료시설 기반에서 소방안전 대처에 관한 교육 매뉴얼의 개발이 필요하다고 사료된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF