• Title/Summary/Keyword: multi-device control

Search Result 359, Processing Time 0.024 seconds

A Study of Marine Network NMEA2000 for e-Navigation

  • Kim, Kyung-Yup;Park, Dong-Hyun;Shim, Jin-Bo;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.133-140
    • /
    • 2010
  • NMEA2000 protocol known as IEC61162-3 of Multi-talker, Multi-listener, PnP communication is adopted as standard network for SOLAS ship by ISO in 2008 for e-navigation ages. NMEA2000 network uses well known CAN in physical layer. In this paper, address claim function is implemented for protocol converter device which can be used easily in combination with CPU of non network device. We are going to implement full function of NMEA2000 protocol and provide guideline to develop ship equipment to be networked easily.

Multi-Channel Vibrotactile Display for Teleoperated Assembly

  • Thomas Debus;Jang, Tae-Jeong;Pierre Dupont;Robert Howe
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.390-397
    • /
    • 2004
  • This paper presents the design and testing of a multi-channel vibrotactile display. It is composed of a cylindrical handle with four embedded vibrating elements driven by piezoelectric beams. Vibrations are transmitted to the hands through arrays of pins. The device was tested in sensory substitution for conveying force information during a teleoperated peg insertion. Results show that the device is effective in reducing peak forces during the insertion task.

Development of Brace-type Wearable Robot for Lumbar Stabilization (요부 안정화를 위한 복대형 입는 로봇 개발)

  • Joowan Kim;Jaehoon Sim;Keewon Kim;Sungun Chung;Jaeheung Park
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 2023
  • An abdominal brace is a recommended treatment for patients with lumbar spinal disorders. However, due to the nature of the static brace, it uniformly compresses the lumbar region, which can weaken the lumbar muscles or create a psychological dependence that worsens the condition of the spine when worn for an extended period of time. Due to these issues, doctors limit the wearing time when prescribing it to patients. In this paper, we propose a device that can dynamically provide abdominal pressure and support according to the lumbar motion. The proposed device is a wearable robot in the form of a brace, with actuators and a driving unit mounted on the brace. To enhance wearability and reduce the weight of the device, worm gears actuator and a multi-pulley mechanism were adopted. Based on the spinal motion of the wearer measured by the Inertia measurement unit sensors, the drives wire by driving pulley, which provide tension to the multi-pulley mechanism on both sides, dynamically tightening or loosening the device. Finally, the device can dynamically provide abdominal pressure and support. We describe the hardware and system configuration of the device and demonstrate its potential through basic control experiments.

Strategy based PSO for Dynamic Control of UPFC to Enhance Power System Security

  • Mahdad, Belkacem;Bouktir, T.;Srairi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.315-322
    • /
    • 2009
  • Penetration and installation of a new dynamic technology known as Flexible AC Transmission Systems (FACTS) in a practical and dynamic network requires and force expert engineer to develop robust and flexible strategy for planning and control. Unified Power Flow Controller (UPFC) is one of the recent and effective FACTS devices designed for multi control operation to enhance the power system security. This paper presents a dynamic strategy based on Particle Swarm Optimization (PSO) for optimal parameters setting of UPFC to enhance the system loadability. Firstly, we perform a multi power flow analysis with load incrementation to construct a global database to determine the initial efficient bounds associated to active power and reactive power target vector. Secondly a PSO technique applied to search the new parameters setting of the UPFC within the initial new active power and reactive power target bounds. The proposed approach is implemented with Matlab program and verified with IEEE 30-Bus test network. The results show that the proposed approach can converge to the near optimum solution with accuracy, and confirm that flexible multi-control of this device coordinated with efficient location enhance the system security of power system by eliminating the overloaded lines and the bus voltage violation.

Energy efficient Medium Access Control for multi-hop sensor network (멀티-홉 센서 네트워크 저전력 MAC 설계)

  • Gang, Jeong-Hun;Lee, Min-Gu;Park, Byeong-Ha;Yu, Jun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.279-282
    • /
    • 2003
  • This paper proposes a medium-access control(MAC) protocol designed for wireless multi-hop sensor networks which is used for connecting physical world and cyber computing space. Wireless multi-hop sensor networks use battery-operated computing and sensing device. We expect sensor networks to be deployed in an ad hoc fashion, with nodes remaining inactive for long time, but becoming suddenly active when specific event is detected. These characteristics of multi-hop sensor networks and applications motivate a MAC that is different from traditional wireless MACs about power conservation scheme, such as IEEE 802.11. Proposed MAC uses a few techniques to reduce energy consumption. Result show that proposed MAC obtains more energy sayings.

  • PDF

A New 6-DOF Parallel Haptic Device: Optimum Design and Analysis (새로운6자유도 병렬형 햅틱 기구의 최적설계 및 해석)

  • 이재훈;김형욱;이병주;서일홍
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.63-72
    • /
    • 2003
  • A new 6-DOF parallel haptic device is proposed. Many existing haptic devices require large power due to having floating actuator and also have small workspaces. The proposed new mechanism can generate 6-DOF reflecting force. This device is relatively light by employing non-floating actuators and has large workspace. Kinematic analysis and kinematic optimal design is performed for this mechanism. Dexterous workspace, global isotropic index, and global maximum force transmission ratio are considered as kinematic design indices. To deal with such multi-criteria optimization problem. composite design index is employed. For the given operational specifications, actuator sizing for this mechanism is also carried out.

A Design of Greenhouse Control Algorithm with the Multiple-Phase Processing Scheme (다중 위상 처리구조를 갖는 온실 복합환경제어 알고리즘 설계)

  • Daewook Bang
    • Journal of Service Research and Studies
    • /
    • v.11 no.2
    • /
    • pp.118-130
    • /
    • 2021
  • This study designs and validates a greenhouse complex environmental control algorithm with a multi-phase processing scheme that can combine and control actuators according to the degree of change in the greenhouse environment. The composite environmental control system is a system in which the complex environmental controller analyzes the information detected by sensors and operates appropriately actuators to maintain the crop growth environment. A composite environmental controller directs control devices driving actuators through a composite environmental control algorithm, which calculates the values necessary for the operation of the control devices. Most existing algorithms carry out control procedures on a single phase by iteration cycle, which can cause abnormal changes in the greenhouse environment due to errors in output. The proposed algorithm distributes control procedures over multiple phases: environmental control, environmental control, and device operation, and every iteration cycle, detects environmental changes in the environmental control phase first, and then combines control devices that can control the environment in the environmental control phase, and finally, performs the controls to derive the actuators in the device operation phase. The proposed algorithm is designed based on the analysis of the relationship between greenhouse environmental elements and control devices deriving actuators. According to verification analysis, the multi-phase processing scheme provides room to modify or supplement the setting value and enables the control devices to reflect changes in the associated environmental components.

Device Control System based on Brain Wave Data (뇌파데이터 기반의 디바이스 제어 시스템)

  • Lee, So-Hyun;Lee, Ye-Jeong;Lee, Seok-cheol;Seo, Jeongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.813-815
    • /
    • 2016
  • This paper implements a device control system based on the brain wave data. Brain-Computer Interface (BCI) technology can pass directly to the system without going through the operation of the language or body. By controlling the device to detect brain waves in real time according to the change of status it helps to ease life for a variety of services, such as disabled people with limited mobility or students, people who need multi-tasking. In addition, it is possible to develop an application service such as the home device control system. A device control system implemented in the paper based on the data collected from the EEG Headset associated to control the power of the smart phone and audio. Control the power ON / OFF operation by the Attention, and support service functions to control the audio by the Meditation and Eye blink. It was confirmed that the device control using the brain wave data to be operated through a laboratory test successfully.

  • PDF

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

3-Axis Gyro Sensor based on Servo Motion Control System (3-Axis Gyro Sensor based on Servo Motion Control 시스템 개발)

  • Sun, Nana;Lee, Won-Bu;Park, Soo-Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.725-727
    • /
    • 2010
  • For simulation of Boat motion, pitch, motion element of roll and yaw direction could simulated. The combination of the marine use various multi sensor surveillance system technology with the development of servo motion control algorithm and gyro sensor in six freedom motion is implemented to analyze the movement response. The stabilization of the motion control is developed and Nano driving Precision Pan-Tilt/Gimbal system is obtained from the security positioning cameras with ultra high speed device is used to carry out the exact behavior of the device.

  • PDF